Appendix A e-Diagtools Error Codes 1000h - 10FFh: Multiple Processor Error Codes Code 100Eh 100Fh 1010h 1011h 1012h 1013h 1014h 1015h 1016h Explanation CPU speed error. CPU count error. Configuration access mechanism test failed. TagRAM control register read failed. TagRAM control register write failed. Value read back from TagRAM control register is not the same as the value written. L2 cache commands test failed. The pattern read back from the cache is not the same as the pattern written. Tag Write with Data Read command failed. Details/Parts to Check Processor speed error. Check processor Speed stamp and clocks. If the error persists, install new processor. Processor error. Check number of processors present. Check processor, L2 cache and main memory are correctly installed. If problem persists, replace processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. Check processor, L2 cache and main memory are correctly installed. If problem persists, install new processor. 98 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

Appendix A
e-Diagtools Error Codes
1000h – 10FFh:
Multiple Processor Error Codes
98
English
100Eh
CPU speed error.
Processor speed error.
Check processor Speed stamp and clocks.
If the error persists, install new processor.
100Fh
CPU count error.
Processor error.
Check number of processors present.
1010h
Configuration access mechanism test
failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, replace processor.
1011h
TagRAM control register read failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
1012h
TagRAM control register write failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
1013h
Value read back from TagRAM control
register is not the same as the value
written.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
1014h
L2 cache commands test failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
1015h
The pattern read back from the cache is
not the same as the pattern written.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
1016h
Tag Write with Data Read command
failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new processor.
Code
Explanation
Details/Parts to Check