HP ProLiant DL388e HP ProLiant DL388e Gen8 Server User Guide - Page 39

Installing a 2 SFF rear drive cage option, Power down the server

Page 39 highlights

c. Connect the SATA cable to the rear drive cage, secure the cable in the cable clip, and then connect the cable to the system board. d. Install the primary PCI riser cage. 10. Connect the rest of the drive cables required in this drive configuration. For more information, see "Storage cabling (on page 82)." 11. Install the drives ("Drive options" on page 34). CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. 12. Install the access panel (on page 21). 13. Install the server into the rack ("Installing the server into the rack" on page 31). 14. Power up the server (on page 18). Installing a 2 SFF rear drive cage option 1. Power down the server (on page 18). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the following: o Extend the server from the rack (on page 18). o Remove the server from the rack (on page 20). 4. Remove the access panel (on page 21). Hardware options installation 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

Hardware options installation 39
c.
Connect the SATA cable to the rear drive cage, secure the cable in the cable clip, and then connect
the cable to the system board.
d.
Install the primary PCI riser cage.
10.
Connect the rest of the drive cables required in this drive configuration. For more information, see
"Storage cabling (on page
82
)."
11.
Install the drives ("
Drive options
" on page
34
).
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
12.
Install the access panel (on page
21
).
13.
Install the server into the rack ("
Installing the server into the rack
" on page
31
).
14.
Power up the server (on page
18
).
Installing a 2 SFF rear drive cage option
1.
Power down the server (on page
18
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
18
).
o
Remove the server from the rack (on page
20
).
4.
Remove the access panel (on page
21
).