Table 20. BMC firmware messages Event Severity Message Temperature Events Acoustic mode Information Blade throttled. Cell/B.E. processor 0 Temp above Warning Temperature (>73 °C) Standard mode Cell/B.E. processor 0 Temp above Warning Temperature (>82 °C) Acoustic mode Information Blade throttled. Cell/B.E. processor 1 Temp above Warning Temperature (>73 °C) Standard mode Cell/B.E. processor 1 Temp above Warning Temperature (>82 °C) Performance modeCell/B.E. Warning processor 0 Temp above Warning Temperature (>80 °C) Performance modeCell/B.E. Warning processor 1 Temp above Warning Temperature (>80 °C) Processor 1 (BE0 Temp) over recommended temperature. Processor 2 (BE1 Temp) over recommended temperature. Automatic Action by BMC Action required by user Throttle (Reduce Frequency). This is a BladeCenter unit operation which reduces processor speed on the blade server concerned until the temperature has dropped to normal levels. Throttle (Reduce Frequency). This is a BladeCenter unit operation which reduces processor speed on the blade server concerned until the temperature has dropped to normal levels. No action required. Advanced Management Module increases blower speed. Advanced Management Module increases blower speed. 90 BladeCenter QS21 Type 0792: Problem Determination and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Table
20.
BMC
firmware
messages
Event
Severity
Message
Automatic
Action
by
BMC
Action
required
by
user
Temperature
Events
Acoustic
mode
Cell/B.E.
processor
0
Temp
above
Warning
Temperature
(>73
°C)
Standard
mode
Cell/B.E.
processor
0
Temp
above
Warning
Temperature
(>82
°C)
Information
Blade
throttled.
Throttle
(Reduce
Frequency).
This
is
a
BladeCenter
unit
operation
which
reduces
processor
speed
on
the
blade
server
concerned
until
the
temperature
has
dropped
to
normal
levels.
No
action
required.
Acoustic
mode
Cell/B.E.
processor
1
Temp
above
Warning
Temperature
(>73
°C)
Standard
mode
Cell/B.E.
processor
1
Temp
above
Warning
Temperature
(>82
°C)
Information
Blade
throttled.
Throttle
(Reduce
Frequency).
This
is
a
BladeCenter
unit
operation
which
reduces
processor
speed
on
the
blade
server
concerned
until
the
temperature
has
dropped
to
normal
levels.
Performance
mode
Cell/B.E.
processor
0
Temp
above
Warning
Temperature
(>80
°C)
Warning
Processor
1
(BE0
Temp)
over
recommended
temperature.
Advanced
Management
Module
increases
blower
speed.
Performance
mode
Cell/B.E.
processor
1
Temp
above
Warning
Temperature
(>80
°C)
Warning
Processor
2
(BE1
Temp)
over
recommended
temperature.
Advanced
Management
Module
increases
blower
speed.
90
BladeCenter
QS21
Type
0792:
Problem
Determination
and
Service
Guide