IBM QS21 Service Guide - Page 72
Problems, indicated, system, board
UPC - 883436016940
View all IBM QS21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Table 3. Explanation of LEDs and their states (continued) LED State Explanation Suggested action Power-on LED Flashing rapidly The service processor on the blade server is communicating with the BladeCenter Management Module. No action required Flashing slowly The blade server has power but Turn on if required is not turned on. Lit continuously (steady) The blade server has power and is turned on. No action required Not lit. Blade server not powered. 1. Reseat blade server. 2. Check if BladeCenter power supplies numbers 3 and 4 are installed and powered. If they are not, install and power them or use slots 1-5. 3. Go to "Power problems" on page 57 Problems indicated by the system board LEDS The blade server must be removed from the BladeCenter unit and the cover removed before you can use the light path LEDs for diagnostics. To activate the light box and the other light path LEDs, press the light path diagnostics switch. The location of each LED on the system board is shown in the table below. Error LED (JDIM11) Error LED (JDIM10) JDIM11 slot JDIM10 slot 1 Temperature fault LED System board LED CPU fail LED NMI error LED LP TEMP S BRD CPU NMI Light box JDIM01 slot JDIM00 slot Error LED (JDIM01) Error LED (JDIM00) Light path diagnostics LED Light path diagnostics switch Figure 26. Light box and system board LEDs 54 BladeCenter QS21 Type 0792: Problem Determination and Service Guide