IBM QS21 Service Guide - Page 85
Table, results, continued
UPC - 883436016940
View all IBM QS21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
Table 6. BMC test results (continued) Test Extended Number Status results Actions 166-904- Fail xxx 166-905- Fail xxx 166-906- Fail xxx 166-907- Fail xxx 166-908- Fail xxx The BMC indicates a failure in the main bus. 1. Turn off the system and disconnect it from power. The system must be removed from AC power in order to reset the BMC. 2. After 45 seconds, reconnect the system to power and turn The BMC on the system. indicates a failure in the pecos bus. The BMC indicates a failure in the BMC private bus. 3. Run the test again. 4. Make sure that the DSA Diagnostic code is at the latest level. The latest level DSA Diagnostic code can be found on the IBM Support Web site at http://www.ibm.com/ support/docview.wss?uid=psg1SERV-DSA/. 5. Check BMC firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this The BMC component. The latest level firmware for this component indicates a can be found on the IBM Support Web site at failure in the http://www.ibm.com/support/us/en/. power backplane 6. Run the test again. bus. 7. If the test continues to fail, refer to the other sections of The BMC this chapter for diagnosis and corrective action. indicates a failure in the microprocessor bus. 166-910- Fail xxx The BMC indicates a failure in the PCIe and Light path diagnostics bus. Chapter 5. Diagnostics and troubleshooting 67