Icom IC-7410 Instruction Manual - Page 113

Character code setting, Data content description

Page 113 highlights

CONTROL COMMAND 14 D Data content description • C haracter code setting Command : 1A 00 Character ASCII code Character ASCII code A-Z 41-5A a-z 61-7A 0-9 30-39 Space 20 ! 21 # 23 $ 24 % 25 & 26 \ 5C ? 3F " 22 ' 27 ` 60 ^ 5E + 2B - 2D ✱ 2A ⁄ 2F . 2E , 2C : 3A ; 3B = 3D < 3C > 3E ( 28 ) 29 [ 5B ] 5D { 7B } 7D ¦ 7C _ 5F ¯ 7E @ 40 • Operating frequency Command : 00, 03, 05 q w e 999999 r 99 t 99 10 Hz digit: 0-9 1 Hz digit: 0-9 1 kHz digit: 0-9 100 Hz digit: 0-9 100 kHz digit: 0-9 10 kHz digit: 0-9 10 MHz digit: 0-9 1 MHz digit: 0-9 1000 MHz digit: 0 (fixed) 100 MHz digit: 0 (fixed) • Operating mode Command : 01, 04, 06 q XX w XX q Operating mode w Filter setting 00: LSB 03: CW 07: CW-R 01: FIL1 01: USB 04: RTTY 08: RTTY-R 02: FIL2 02: AM 05: FM 03: FIL3 Filter setting (w) can be skipped with command 01 and 06. In that case, "FIL1" is automatically selected with command 01 and the default filter setting of the operating mode is selected with command 06. • Band edge frequency setting Command 02*, 1E 01, 1E 03 q w e r t y u i o !0 !1 !2 XXXXXXXXXXXX 2 DXXXXXXXXXX Edge number*: 01-30 10 Hz digit: 0-9 1 Hz digit: 0-9 1 kHz digit: 0-9 100 Hz digit: 0-9 100 kHz digit: 0-9 10 kHz digit: 0-9 10 MHz digit: 0-9 1 MHz digit: 0-9 1000 MHz digit: 0 (fixed) 100 MHz digit: 0 (fixed) Separator (fixed) 10 Hz digit: 0-9 1 Hz digit: 0-9 1 kHz digit: 0-9 100 Hz digit: 0-9 100 kHz digit: 0-9 10 kHz digit: 0-9 10 MHz digit: 0-9 1 MHz digit: 0-9 1000 MHz digit: 0 (fixed) 100 MHz digit: 0 (fixed) Lower edge Higher edge * Edge number setting is not necessary with command 02. • Band stacking register Command : 1A 01 q w XXXX q Frequency band code Code Freq. band Frequency range (unit: MHz) 01 1.8 1.800000- 1.999999 02 3.5 3.400000- 4.099999 03 7 6.900000- 7.499999 04 10 9.900000-10.499999 05 14 13.900000-14.499999 06 18 17.900000-18.499999 07 21 20.900000-21.499999 08 24 24.400000-25.099999 09 28 28.000000-29.999999 10 50 50.000000-54.000000 11 GENE Other than above w Register code Code 01 02 03 Registered No. 1 (latest) 2 3 (oldest) For example, when reading the oldest contents in the 21 MHz band, the code "0703" is used. When sending the contents, the codes, such as operating frequency and operating mode*, should be added after the register code, as shown above. *See "Memory content setting (r to !8)" for details. (p. 108) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 106

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

106
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
19
20
21
14
18
14
Character code setting
Command : 1A 00
Character
ASCII code
Character
ASCII code
A–Z
41–5A
a–z
61–7A
0–9
30–39
Space
20
!
21
#
23
$
24
%
25
&
26
\
5C
?
3F
"
22
27
`
60
^
5E
+
2B
2D
2A
2F
.
2E
,
2C
:
3A
;
3B
=
3D
<
3C
>
3E
(
28
)
29
[
5B
]
5D
{
7B
}
7D
¦
7C
_
5F
¯
7E
@
40
• Operating frequency
Command : 00, 03, 05
q
X
X
X
X
X
w
e
X
r
t
X
X
X
X
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
1000 MHz digit:
0 (fixed)
100 MHz digit:
0 (fixed)
• Operating mode
Command : 01, 04, 06
q
X
X
X
X
w
q
Operating mode
w
Filter setting
00: LSB
03: CW
07: CW-R
01: FIL1
01: USB
04: RTTY
08: RTTY-R
02: FIL2
02: AM
05: FM
03: FIL3
Filter setting (
w
) can be skipped with command 01
and 06. In that case, “FIL1” is automatically selected
with command 01 and the default filter setting of the
operating mode is selected with command 06.
• Band edge frequency setting
Command 02*, 1E 01, 1E 03
q
XXX
w
e
r
t
y
u
i
o
!0
!1
!2
XX
XX
XX
XX
X2
DX
XX
XX
XX
XX
X
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
1000 MHz digit: 0 (fixed)
100 MHz digit: 0 (fixed)
Separator (fixed)
Lower edge
Higher edge
Edge number*: 01–30
* Edge number setting is not necessary with com-
mand 02.
• Band stacking register
Command : 1A 01
q
X
X
X
X
w
q
Frequency band code
Code
Freq. band
Frequency range (unit: MHz)
01
1.8
1.800000– 1.999999
02
3.5
3.400000– 4.099999
03
7
6.900000– 7.499999
04
10
9.900000–10.499999
05
14
13.900000–14.499999
06
18
17.900000–18.499999
07
21
20.900000–21.499999
08
24
24.400000–25.099999
09
28
28.000000–29.999999
10
50
50.000000–54.000000
11
GENE
Other than above
w
Register code
Code
Registered No.
01
1 (latest)
02
2
03
3 (oldest)
For example, when reading the oldest contents in the
21 MHz band, the code “0703” is used.
When sending the contents, the codes, such as op-
erating frequency and operating mode*, should be
added after the register code, as shown above.
*See “Memory content setting (
r
to
!8
)” for details.
(p. 108)
D
Data content description