Page 98 highlights
10 SET MODE ■ Tone Control Set mode description (Continued) 9. TBW(MID) L (Mode: SSB) (Default: 300) Set the lower cut-off frequency of the transmission passband width for your mid setting to 100, 200, 300 or 500 Hz. 10. TBW(MID) H (Mode: SSB) (Default: 2700) Set the higher cut-off frequency of the transmission passband width for your mid setting to 2500, 2700, 2800 or 2900 Hz. 11. TBW(NAR) L (Mode: SSB) (Default: 500) Set the lower cut-off frequency of the transmission passband width for your narrow setting to 100, 200, 300 or 500 Hz. 12. TBW(NAR) H (Mode: SSB) (Default: 2500) Set the higher cut-off frequency of the transmission passband width for your narrow setting to 2500, 2700, 2800 or 2900 Hz. 91
![](/manual_guide/products/icom-ic7410-instruction-manual-6fdb052/98.png)
91
SET MODE
10
TBW(MID) L
9.
(Default: 300)
(Mode: SSB)
Set the lower cut-off frequency of the transmission
passband width for your mid setting to 100, 200, 300
or 500 Hz.
TBW(MID) H
10.
(Default: 2700)
(Mode: SSB)
Set the higher cut-off frequency of the transmission
passband width for your mid setting to 2500, 2700,
2800 or 2900 Hz.
TBW(NAR) L
11.
(Default: 500)
(Mode: SSB)
Set the lower cut-off frequency of the transmission
passband width for your narrow setting to 100, 200,
300 or 500 Hz.
TBW(NAR) H
12.
(Default: 2500)
(Mode: SSB)
Set the higher cut-off frequency of the transmission
passband width for your narrow setting to 2500, 2700,
2800 or 2900 Hz.
■
Tone Control Set mode description (Continued)