Intel SR1625UR Service Guide - Page 100
Replacing or Adding a Power Supply
![]() |
View all Intel SR1625UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
AF002865 Figure 68. Replacing the Backup Battery 6. Dispose of the battery according to local ordinance. 7. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. Note: You will need to run the BIOS Setup to restore the configuration settings to the RTC. Replacing or Adding a Power Supply Caution: The power supply is only hot-swappable if you have a redundant system with two power supplies installed. If you only have one power supply installed, before removing or replacing the power supply, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, follow these steps: 1. Do one of the following: - If a filler panel is installed, use the finger hole to remove the filler panel (see Figure 69). 82 Intel® Server System SR1625UR Service Guide