Intel SR1625UR Service Guide - Page 78

Removing Drive Blank from Drive Carrier, Installing Hard Drive into Carrier

Page 78 highlights

B A AF002850 Figure 45. Removing Drive Blank from Drive Carrier 4. Remove the hard drive from its wrapper and place it on an anti-static surface. 5. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 6. With the drive circuit-side down, position the connector end of the drive so that it is facing the rear of the drive carrier. 7. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier using the four screws that were attached to the plastic retention device (see letter "B" in Figure 46). B A TP02231 Figure 46. Installing Hard Drive into Carrier 8. With the black lever held in the fully open position, slide the hard disk assembly into the server system and push all the way until it clicks (see letter "A" in Figure 47). 60 Intel® Server System SR1625UR Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

60
Intel
®
Server System SR1625UR Service Guide
Figure 45. Removing Drive Blank from Drive Carrier
4.
Remove the hard drive from its wrapper and place it on an anti-static surface.
5.
Set any jumpers and/or switches on the drive according to the drive manufacturer's
instructions.
6.
With the drive circuit-side down, position the connector end of the drive so that it is
facing the rear of the drive carrier.
7.
Align the holes in the drive to the holes in the drive carrier and attach it to the
carrier using the four screws that were attached to the plastic retention device (see
letter “B” in
Figure 46
).
Figure 46. Installing Hard Drive into Carrier
8.
With the black lever held in the fully open position, slide the hard disk assembly
into the server system and push all the way until it clicks (see letter “A” in
Figure 47
).
AF002850
A
B
TP02231
A
B