Intel SR1625UR Service Guide - Page 121
System Environmental Specifications
![]() |
View all Intel SR1625UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
System Environmental Specifications The following table defines the system level operating and non-operating environmental limits. Table 7. System Environmental Specifications Temperature Non-operating Operating Humidity Non-operating Shock Operating Packaged Unpackaged Acoustic noise Electrostatic discharge (ESD) System Cooling Requirement in BTU/Hr -40° to 70°C. 10°C to 35°C with the maximum rate of change not to exceed 10°C per hour 90% relative humidity (non-condensing) at 28°C. 2.0 g, 11 msec, half sine Non-palletized free fall in height 24 inches (> 40 lbs to < 80 lbs). Trapezoidal, 25 g, velocity change 136 inches/sec. Sound Power: 7.0 BA in an idle state at typical office ambient temperature (23 +/- 2°C). +/-12 KV except I/O port +/- 8 KV per Intel® Environment test specification. 2550 BTU/Hr Intel® Server System SR1625UR Service Guide 103