Intel SR1625UR Service Guide - Page 69

Installing the Memory, Insert the bottom edge of the DIMM into the socket .

Page 69 highlights

3. Locate the DIMM sockets (see Figure 35). DIMM B2 DIMM A1 DIMM A2 E C D B A DIMM B1 DIMM C2 DIMM C1 DIMM F1 DIMM F2 DIMM E1 DIMM D2 DIMM D1 DIMM E2 AF002884 Figure 35. Installing the Memory 4. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (see letter "A" in Figure 35). 5. Holding the DIMM by the edges, remove it from its anti-static package. 6. Position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with the key in the DIMM socket (see letter "B" in Figure 35 - the arrow is pointing to the key in the socket). 7. Insert the bottom edge of the DIMM into the socket . 8. When the DIMM is correctly positioned, push down on the top edge of the DIMM until the retaining clips snap into place (see letter "C" in Figure 35). 9. Make sure the clips are firmly in place (see letter "D" in Figure 35). Intel® Server System SR1625UR Service Guide 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

Intel
®
Server System SR1625UR Service Guide
51
3.
Locate the DIMM sockets (see
Figure 35
).
Figure 35. Installing the Memory
4.
Make sure the clips at either end of the DIMM socket(s) are pushed outward to the
open position (see letter “A” in
Figure 35
).
5.
Holding the DIMM by the edges, remove it from its anti-static package.
6.
Position the DIMM above the socket. Align the notch on the bottom edge of the
DIMM with the key in the DIMM socket (see letter “B” in
Figure 35
- the arrow is
pointing to the key in the socket).
7.
Insert the bottom edge of the DIMM into the socket .
8.
When the DIMM is correctly positioned, push down on the top edge of the DIMM
until the retaining clips snap into place (see letter “C” in
Figure 35
).
9.
Make sure the clips are firmly in place (see letter “D” in
Figure 35
).
AF002884
DIMM B2
DIMM A1
DIMM A2
DIMM B1
DIMM C2
DIMM C1
DIMM F1
DIMM F2
DIMM E1
DIMM D2
DIMM D1
DIMM E2
D
A
B
E
C