Intel SR1625UR Service Guide - Page 108
Replacing a System Fan
View all Intel SR1625UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Replacing a System Fan Caution: The system fans are NOT hot-swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. Note: The fans that are integrated into the power supply cannot be replaced separately. If one of the fans in the power supply fails, the power supply must be replaced. The system fans at the front of the Intel® Server System SR1625UR can be individually replaced if one of them fails. To replace a system fan, follow these steps: 1. Disconnect the fan cable from the midplane board (see letter "A" in Figure 79). 2. Lift the failed fan from the module (see letter "B" in Figure 79). There are no screws to loosen. A B AF002870 Figure 79. Removing a System Fan 3. Position the replacement fan so the connector on the fan is at the right and pointing down. 90 Intel® Server System SR1625UR Service Guide