Intel SR1625UR Service Guide - Page 79

Removing a Hot-swap SAS/SATA Hard Disk Drive, Installing a Hot-swap SAS/SATA Hard

Page 79 highlights

9. Close the lever to lock the drive assembly into place (see letter "B" in Figure 47).) A B AF002874 Figure 47. Install Drive Assemby into the Server System Removing a Hot-swap SAS/SATA Hard Disk Drive To remove a hot-swap SAS/SATA hard disk drive, follow these steps: 1. Press in on the green latch at the front of the hard drive carrier. 2. Pull out on the black lever to slide the carrier out from the server system. 3. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier and store the drive in an anti-static bag. 4. Do one of the following: - To install the replacement drive, see "Installing a Hot-swap SAS/SATA Hard Disk Drive" on page 59. - If you are not installing a drive, place the plastic retention device into the drive carrier and secure the device by inserting the four screws you removed from the hard drive into the screw locations on the carrier. Note: To maintain proper system cooling, all hard drive carriers must be installed in the server system and populated with either a drive or a drive blank. 5. With the black lever held in the fully open position, slide the drive carrier into the server system and push all the way until it clicks. 6. Close the lever to lock the drive assembly into place. Intel® Server System SR1625UR Service Guide 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

Intel
®
Server System SR1625UR Service Guide
61
9.
Close the lever to lock the drive assembly into place (see letter “B” in
Figure 47
).
)
Figure 47. Install Drive Assemby into the Server System
Removing a Hot-swap SAS/SATA Hard Disk Drive
To remove a hot-swap SAS/SATA hard disk drive, follow these steps:
1.
Press in on the green latch at the front of the hard drive carrier.
2.
Pull out on the black lever to slide the carrier out from the server system.
3.
Remove the four screws that attach the hard drive to the drive carrier. Lift the drive
from the carrier and store the drive in an anti-static bag.
4.
Do one of the following:
To install the replacement drive, see
“Installing a Hot-swap SAS/SATA Hard
Disk Drive” on page 59
.
If you are not installing a drive, place the plastic retention device into the drive
carrier and secure the device by inserting the four screws you removed from the
hard drive into the screw locations on the carrier.
Note:
To maintain proper system cooling, all hard drive carriers must be installed in the server
system and populated with either a drive or a drive blank.
5.
With the black lever held in the fully open position, slide the drive carrier into the
server system and push all the way until it clicks.
6.
Close the lever to lock the drive assembly into place.
A
B
AF002
8
74