Kyocera ECOSYS P5021cdw ECOSYS P5021cdn/P5021cdw/M5026cdn/P5026cdw Operation G - Page 192
Chart Example, Adjust/Maintenance, Registration Details, M 12345, Display the correction menu.
View all Kyocera ECOSYS P5021cdw manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 192 highlights
Troubleshooting > Adjustment/Maintenance Chart Example 4 Display the correction menu. [Menu] key key > [Adjust/Maintenance] > [►] key key > [Registration Details] > [►] key key > [M 12345 3] > [OK] key The magenta correction menu appears. 5 Enter the appropriate value. 1 Find the location on each chart where 2 lines most closely match. If this is the 0 position, registration for that color is not required. For the illustration, B is the appropriate value. From charts H-1 to H-5, read the values from H-1 to H-5. From charts V-1 to V-5, read only the values from V-3 (center). 2 Select the [◄] or [►] key to change the H and V items, select the [▲] or [▼] key to enter the values read from the chart, and select the [OK] key. To increase the value from 0 up to a maximum of 9, select the [▲] key. To decrease the value, select the [▼] key. Select [▼] to change the value from 0 to an alphabetical letter. Continue selecting to change from A through l. To move in the opposite direction, select [▲]. 3 Select the [OK] key. Magenta correction is completed. 4 Repeat steps 3 to 4 to correct cyan and yellow. 8-24