Lantronix G520 G520 User Guide - Page 113

Data Window, Modbus Download, Modbus RTU to DNP3

Page 113 highlights

10: Services Data Window This page shows data by polling group. The polling groups are defined in the configuration file. 1. Click Enable Data Window to allow data to be read from the data window. This enables data logging for 5 minutes. 2. Select the polling group number and click Show Data to display the data for the specified polling group. Modbus Download This page allows you to download the Modbus configuration file in CSV format. Click Download to download the Modbus configuration file. The file is downloaded, or a message is displayed if there is no Modbus configuration file found. Modbus RTU to DNP3 Services > Modbus RTU to DNP3 The G520 series gateway acts as a DNP3 outstation. DNP3 is an open standard communication protocol used in many SCADA environments. On the G520 series gateway, DNP3 has the following functionality:  DNP3 serial to DNP3 over TCP by tunneling. DNP3 master communicates with DNP3 outstation using tunnel over RS-232 or RS-485. For configuration, see Serial Line Configuration on page 198.  Modbus RTU to DNP3 conversion. The G520 series gateway facilitates the DNP3 master (DNP3 SCADA) to connect and monitor the Modbus RTU device connected over RS-232 or RS-485. Configure DNP3 Outstation for Modbus RTU to DNP3 conversion To use this feature, configure the DNP3 outstation, then configure the serial interface (RS-232 or RS-485), and then generate the Modbus Master configuration file with the DNP3 parameters added. To configure the DNP3 outstation: 1. Go to Services > DNP3. 2. Select Enable to enable DNP3. 3. Under Outstation, enter the DNP3 outstation server, link layer and database configuration settings. See Table 10-22. 4. In the Outstation section under Modbus Configuration, select Enable and then upload the Modbus configuration file with DNP3 parameters to the /etc folder. For details on how to create the configuration file, see Modbus Master Configuration File for DNP3 Outstation. 5. Click Save & Apply. Table 10-22 DNP3 Outstation Configuration Parameters DNP3 Server Configuration Description G520 Series IoT Cellular Gateway User Guide 113

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225

10: Services
G520 Series IoT Cellular Gateway User Guide
113
Data Window
This page shows data by polling group. The polling groups are defined in the configuration file.
1.
Click
Enable Data Window
to allow data to be read from the data window. This enables data
logging for 5 minutes.
2.
Select the polling group number and click
Show Data
to display the data for the specified
polling group.
Modbus Download
This page allows you to download the Modbus configuration file in CSV format.
Click
Download
to download the Modbus configuration file. The file is downloaded, or a message
is displayed if there is no Modbus configuration file found.
Modbus RTU to DNP3
Services > Modbus RTU to DNP3
The G520 series gateway acts as a DNP3 outstation. DNP3 is an open standard communication
protocol used in many SCADA environments. On the G520 series gateway, DNP3 has the
following functionality:
DNP3 serial to DNP3 over TCP by tunneling. DNP3 master communicates with DNP3
outstation using tunnel over RS-232 or RS-485. For configuration, see
Serial Line
Configuration on page 198
.
Modbus RTU to DNP3 conversion. The G520 series gateway facilitates the DNP3 master
(DNP3 SCADA) to connect and monitor the Modbus RTU device connected over RS-232 or
RS-485.
Configure DNP3 Outstation for Modbus RTU to DNP3 conversion
To use this feature, configure the DNP3 outstation, then configure the serial interface (RS-232 or
RS-485), and then generate the Modbus Master configuration file with the DNP3 parameters
added.
To configure the DNP3 outstation:
1.
Go to Services > DNP3.
2.
Select
Enable
to enable DNP3.
3.
Under Outstation, enter the DNP3 outstation server, link layer and database configuration
settings. See
Table 10-22
.
4.
In the Outstation section under Modbus Configuration, select
Enable
and then upload the
Modbus configuration file with DNP3 parameters to the /etc folder. For details on how to create
the configuration file, see
Modbus Master Configuration File for DNP3 Outstation
.
5.
Click
Save & Apply
.
Table 10-22
DNP3 Outstation Configuration
Parameters
Description
DNP3 Server Configuration