Lantronix SLC 8000 Advanced Console Manager User Guide - Page 329
Internal Temperature, Site Information, SLC Firmware, Data Center Rack Row
View all Lantronix SLC 8000 Advanced Console Manager manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 329 highlights
13: Maintenance 2. Enter the following: Reboot Shutdown Select this option to reboot the SLC 8000 advanced console manager immediately. The default is No. Note: The front panel LCD displays the "Rebooting the SLC" message, and the normal boot sequence occurs. Select this option to shut down the SLC unit. The default is No. Internal Temperature Current Low High Calibrate Offset Displays current temperature. Sets the acceptable minimum for the internal temperature of the SLC 8000 advanced console manager. If the temperature of the SLC device changes to be outside of this range, the SLC console manager will issue an SNMP trap. Sets the acceptable maximum for the internal temperature of the SLC unit. If the temperature of the SLC 8000 advanced console manager changes to be outside of this range, the SLC unit will issue an SNMP trap. An offset for calibrating the internal temperature of the SLC console manager. The offset will be applied one hour after setting the calibration value. Zeroing the offset will take effect immediately and will cancel any current and/or pending calibration. Site Information Data Center Rack Row Set these fields to define the rack row the SLC unit is located within a large data center. The default for these fields is 1. Data Center Rack Cluster Set these fields to define the rack cluster the SLC 8000 advanced console manager is located within a large data center. The default for these fields is 1. Data Center Rack Set these fields to define the rack the SLC unit is located within a large data center. The default for these fields is 1. Site Tag Tag or description used to identify the location or some other attribute of the SLC. SLC Firmware Note: The non-active boot bank is updated during the firmware update, without requiring a reboot. The configuration on the current boot bank may optionally be copied to the nonactive boot bank during the firmware update. Current Version Clear FW Update Log (checkbox) Firmware Update Log (link) Update Firmware Firmware Filename Displays the current firmware version. Clears the contents of the Firmware Update log file. To view a log of all prior firmware updates, click the Firmware Update Log link. To update the SLC firmware, select the checkbox. If you select this option, the SLC unit reboots after you apply the update. The first time boot for each bank may take up to 5 minutes. Subsequent boot times will be approximately 2 minutes. To view a log of all prior firmware updates, click the Firmware Update Log link. The name of the firmware update file downloaded from the Lantronix web site. SLC™ 8000 Advanced Console Manager User Guide 329