TP-Link TL-SG2424P TL-SG2424P V1 CLI Reference Guide - Page 153

Parameter, Command Mode, falling-event-index, a-type, owner, interval, no rmon alarm

Page 153 highlights

f-hold ] [ falling-event-index f-event ] [ a-type { rise | fall | all }] [ owner owner-name ] [ interval interval ] no rmon alarm index Parameter index ii The index number of the Alarm Management entry, ranging from 1 to 12, in the format of 1-3,5. port ii The Ethernet port number. alarm-variable ii The alarm variable. By default, the option is "drop". s-type ii Sample Type, which is the sampling method for the selected variable and comparing the value against the thresholds. There are two options, absolute and delta. Absolute indicates comparing the values directly with the thresholds at the end of the sampling interval. Delta indicates subtracting the last sampled value from the current value, and then comparing the difference in the values with the threshold. By default, the Sample Type is "absolute". r-hold -- The rising counter value that triggers the Rising Threshold alarm, ranging from 1 to 65535. By default, it is 100. r-event -- Rise Event, which is the index of the corresponding event which will be triggered if the sampled value is larger than the Rising Threshold. It ranges from 1 to 12. f-hold -- The falling counter value that triggers the Falling Threshold alarm, ranging from 1 to 65535. By default, it is 100. f-event -- Fall Event, which is the index of the corresponding event which will be triggered if the sampled value is lower than the Falling Threshold. It ranges from 1 to 12. a-type -- Alarm Type, with rise, fall and all options. Rise indicates that the alarm event will be triggered when the sampled value exceeds the Rising Threshold, fall indicates that the alarm event will be triggered when the sampled value is under the Falling Threshold, and all indicates that the alarm event will be triggered either the sampled value exceeds the Rising Threshold or is under the Falling Threshold. By default, the Alarm Type is "all". owner-name ii The owner of the entry, ranging from 1 to 16 characters. By default, it is "monitor". interval ii The alarm interval time, ranging from 10 to 3600 in seconds. By default, it is 1800. Command Mode Global Configuration Mode 143

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

143
f-hold
] [
falling-event-index
f-event
] [
a-type
{ rise | fall | all }] [
owner
owner-name
] [
interval
interval
]
no rmon alarm
index
Parameter
index
——
The index number of the Alarm Management entry, ranging from 1
to 12, in the format of 1-3,5.
port
——
The Ethernet port number.
alarm-variable
——
The alarm variable. By default, the option is “drop”.
s-type
——
Sample Type, which is the sampling method for the selected
variable and comparing the value against the thresholds. There are two options,
absolute and delta. Absolute indicates comparing the values directly with the
thresholds at the end of the sampling interval. Delta indicates subtracting the
last sampled value from the current value, and then comparing the difference in
the values with the threshold. By default, the Sample Type is “absolute”.
r-hold
—— The rising counter value that triggers the Rising Threshold alarm,
ranging from 1 to 65535. By default, it is 100.
r-event
—— Rise Event, which is the index of the corresponding event which will
be triggered if the sampled value is larger than the Rising Threshold. It ranges
from 1 to 12.
f-hold
—— The falling counter value that triggers the Falling Threshold alarm,
ranging from 1 to 65535. By default, it is 100.
f-event
—— Fall Event, which is the index of the corresponding event which will
be triggered if the sampled value is lower than the Falling Threshold. It ranges
from 1 to 12.
a-type —— Alarm Type, with rise, fall and all options. Rise indicates that the
alarm event will be triggered when the sampled value exceeds the Rising
Threshold, fall indicates that the alarm event will be triggered when the sampled
value is under the Falling Threshold, and all indicates that the alarm event will
be triggered either the sampled value exceeds the Rising Threshold or is under
the Falling Threshold. By default, the Alarm Type is “all”.
owner-name
——
The owner of the entry, ranging from 1 to 16 characters. By
default, it is “monitor”.
interval
——
The alarm interval time, ranging from 10 to 3600 in seconds. By
default, it is 1800.
Command Mode
Global Configuration Mode