TP-Link TL-SG2424P TL-SG2424P V1 CLI Reference Guide - Page 161

lldp med-fast-count, lldp receive

Page 161 highlights

be sent out (the number of LLDPDUs equals this parameter). The value ranges from 1 to 10 and the default value is 3. Command Mode Global Configuration Mode Example Specify the Transmit Interval of LLDPDU as 45 seconds and Trap message to NMS as 120 seconds: TL-SG2424P(config)# lldp timer tx-interval 45 TL-SG2424P(config)# lldp timer notify-interval 120 lldp med-fast-count Description The lldp med-fast-count command is used to configure the number of the LLDP-MED frames that will be sent out. When LLDP-MED fast start mechanism is activated, multiple LLDP-MED frames will be transmitted based on this parameter. The default value is 4. To return to the default configuration, please use no lldp med-fast-count command. Syntax lldp med-fast-count count no lldp med-fast-count Parameter count -- Configure the Fast Start Count parameter. It ranges from 1 to 10. By default, it is 4. Command Mode Global Configuration Mode Example Specify Fast Start Count as 5: TL-SG2424P(config)# lldp med-fast-count 5 lldp receive Description The lldp receive command is used to enable the designated port to receive LLDPDU. To disable the function, please use no lldp receive command. 151

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

151
be sent out (the number of LLDPDUs equals this parameter). The value ranges
from 1 to 10 and the default value is 3.
Command Mode
Global Configuration Mode
Example
Specify the Transmit Interval of LLDPDU as 45 seconds and Trap message to
NMS as 120 seconds:
TL-SG2424P(config)# lldp timer tx-interval
45
TL-SG2424P(config)# lldp timer notify-interval
120
lldp med-fast-count
Description
The
lldp med-fast-count
command is used to configure the number of the
LLDP-MED frames that will be sent out. When LLDP-MED fast start mechanism
is activated, multiple LLDP-MED frames will be transmitted based on this
parameter. The default value is 4. To return to the default configuration, please
use
no lldp med-fast-count
command.
Syntax
lldp med-fast-count
count
no lldp med-fast-count
Parameter
count
—— Configure the Fast Start Count parameter. It ranges from 1 to 10. By
default, it is 4.
Command Mode
Global Configuration Mode
Example
Specify Fast Start Count as 5:
TL-SG2424P(config)# lldp med-fast-count
5
lldp receive
Description
The
lldp receive
command is used to enable the designated port to receive
LLDPDU. To disable the function, please use
no lldp
receive
command.