Brother International S-7200B Service Manual - Page 35

Adjusting of the feed dog height, Tighten the screw 2.

Page 35 highlights

6. ADJUSTMENTS 6-6. Adjusting of the feed dog height 0.8mm 1.2mm The standard height of the feed dog (1) when it is at its maximum height above the top of the needle plate is 0.8 mm for -[][]S / [][]3 specifications, and 1.2 mm for -[][]5 specifications. Becomes higher Becomes lower 2279M 3696M 1. Turn the pulley until the feed dog (1) rises to the highest position. 2. Tilt back the machine head. 3. Loosen the screw (2). 4. Turn the feed lifting rock bracket stud (3) within a range of 90° from the reference line (4) to adjust the vertical height of the feed bar (5). (Fig. [A]) 5. Tighten the screw (2). * If you are worried about the angle of the feed dog (1), turn the shaft (6) while carrying out the above adjustment. (Fig. [B]) (Refer to "6-7. Adjusting the feed dog angle" on the next page for details of this operation.) Becomes higher Standard Becomes lower Needle plate 2281M Becomes higher Standard Becomes higher Standard Becomes lower Becomes lower 2282M S-7200B 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

S-7200B
6. ADJUSTMENTS
28
6-6. Adjusting of the feed dog height
The standard height of the feed dog (1) when it is at its
maximum height above the top of the needle plate is 0.8 mm
for -[][]S / [][]3 specifications, and 1.2 mm for -[][]5 specifica-
tions.
1. Turn the pulley until the feed dog (1) rises to the highest
position.
2. Tilt back the machine head.
3. Loosen the screw (2).
4. Turn the feed lifting rock bracket stud (3) within a range of
90° from the reference line (4) to adjust the vertical height
of the feed bar (5). (Fig. [A])
5. Tighten the screw (2).
* If you are worried about the angle of the feed dog (1), turn
the shaft (6) while carrying out the above adjustment. (Fig.
[B])
(Refer to “6-7. Adjusting the feed dog angle” on the next
page for details of this operation.)
2279M
<-[][]S / [][]3>
0.8mm
<-[][]5>
1.2mm
Becomes
higher
Becomes
lower
3696M
Standard
Becomes lower
Becomes higher
2281M
2282M
Standard
Becomes lower
Becomes higher
Standard
Becomes lower
Becomes higher
Needle plate