Compaq ProLiant 6400R Compaq ProLiant 6400R Setup and Installation Guide - Page 122

Core Frequency Switch (SW2 and SW3), Table C-2

Page 122 highlights

C-2 Compaq ProLiant 6400R Setup and Installation Guide Core Frequency Switch (SW2 and SW3) For the location of the core frequency switch (SW2 and SW3), see the hood label under the top access panel of the server. The table below describes the core frequency switch (SW2 and SW3) positions for the processors: Table C-2 Core Frequency Switch (SW2 and SW3) Switch Position Core Frequency S1 S2 S3 S4 Processor (MHz) Off On Off On 450 On On Off Off 500 Off On Off Off 550 NOTE: SW2 applies to processors 1 and 2; SW3 applies to processors 3 and 4. The off position indicates a switch is open. NOTE: Compaq makes no representation or warranty that processors, which operate at any of the speeds shown, will be available at any time. Therefore, processor core speeds shown are not necessarily representative of future processors.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

C-2
Compaq ProLiant 6400R Setup and Installation Guide
Core Frequency Switch (SW2 and SW3)
For the location of the core frequency switch (SW2 and SW3), see the hood
label under the top access panel of the server. The table below describes the
core frequency switch (SW2 and SW3) positions for the processors:
Table C-2
Core Frequency Switch (SW2 and SW3)
Switch Position
Core Frequency
S1
S2
S3
S4
Processor (MHz)
Off
On
Off
On
450
On
On
Off
Off
500
Off
On
Off
Off
550
NOTE:
SW2 applies to processors 1 and 2; SW3 applies to processors 3 and 4. The off
position indicates a switch is open.
NOTE:
Compaq makes no representation or warranty that processors, which operate at any
of the speeds shown, will be available at any time. Therefore, processor core speeds shown
are not necessarily representative of future processors.