Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 119
Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
3-22 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1751-Fixed Disk 1 failed Identify command None Fixed disk drive error detected. 1752-Slot X Drive None The array controller cannot Array - This access physical system memory controller is not above the 3 GB address range. supported in systems with more than 3 GB of memory. The array controller will be disabled. (RESUME = F1 KEY) 1760-Fixed Disk 0 does not support Block Mode None Fixed disk drive error detected. 1761-Fixed Disk 1 does not support Block Mode None Fixed disk drive error detected. 1764-Slot X Drive Array - Capacity Expansion Process is temporarily disabled (followed by one of the following) Expansion will resume when Array Accelerator has been reattached. Expansion will resume when Array Accelerator has been replaced. Expansion will resume when Array Accelerator RAM allocation is successful. Expansion will resume when Array Accelerator battery reaches full charge. Expansion will resume when automatic data recovery has been completed. 1765-Slot X Drive Array Option ROM Appears to Conflict With an ISA Card. ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with the SMART-2/E 8-bit Option ROM due to EISA bus limitations. Please remove or reconfigure the ISA card 1766-Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq Utility. 1767-Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict with the Memory Address Range of an ISA Card. Check the Memory Address Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt SMART-2/E Option ROM Reprogramming. Recommended Action Run the System Configuration Utility and correct. Remove the array controller and replace with a version that will address memory in the required range. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Reattach or replace array accelerator, wait until the array accelerator batteries have charged, or for Automatic Data Recovery to complete, as indicated. 1. Remove or reconfigure conflicting ISA cards. 2. Disable "shared memory" on any ISA network cards that may be installed. Run the latest Systems ROMPaq Utility to upgrade the System ROM as indicated. Remove or reconfigure conflicting ISA cards, especially any cards that are not recognized by the System Configuration Utility. Try reprogramming the ROM on the SMART-2/E Controller using the latest Options ROMPaq (version 2.29 or higher). continued