Page 53 highlights
2-36 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide Hot-Plug I/O Fan Board To remove the hot-plug I/O fan board: 1. Remove the top access panel. See "Top Access Panel" earlier in this chapter. 2. Remove the hot-plug front I/O fans. See "Hot-Plug Front I/O Fans" earlier in this chapter. 3. Remove the two Torx T-8 screws securing the hot-plug I/O fan board to the fan cage . 4. Slide the board from beneath the hot-plug I/O fan cage, then lift it out of the server . 1 2 Figure 2-31. Removing the hot-plug I/O fan board Reverse steps 1 through 4 to replace the hot-plug I/O fan board.
2-36
Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide
Hot-Plug I/O Fan Board
To remove the hot-plug I/O fan board:
1.
Remove the top access panel. See
“
Top Access Panel
”
earlier in this chapter.
2.
Remove the hot-plug front I/O fans. See
“
Hot-Plug Front I/O Fans
”
earlier in this chapter.
3.
Remove the two Torx T-8 screws securing the hot-plug I/O fan board to the fan cage
.
4.
Slide the board from beneath the hot-plug I/O fan cage, then lift it out of the server
.
1
2
Figure 2-31.
Removing the hot-plug I/O fan board