Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 183
Redundant ROM Image Recovery
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
3-86 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide 10. After successful completion of this process: a. Turn off the server. b. Reset configuration switches 1, 4, 5, and 6. Refer to the Configuration Switches table within this section. c. Turn on the server as usual. IMPORTANT: If you are performing this procedure on a server with redundant ROM, where both ROM images have been corrupted, repeat the process in succession (once for each corrupt image). If only one image is corrupt, read the following section, "Redundant ROM Image Recovery," for complete instructions. After a failed ROMPaq, power down the server and repeat the above process. Redundant ROM Image Recovery If power is interrupted during the flash process on a server that has redundant ROM, the server should come up as usual (on the same image that it booted) but the inactive (redundant) ROM image will be corrupt. A POST error message displays: 105 - Current System ROM is corrupt - now booting redundant System ROM In this situation, you are required to flash again so that the invalid image is now valid. After you flash the invalid image, the system will boot to that image, which was the original objective.