Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 136
Diskette Drive Test Error Codes, Table 3-8
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Diagnostics and Troubleshooting 3-39 600 - 699, Diskette Drive Test Error Codes The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or system board functions. Table 3-8 Diskette Drive Test Error Codes Error Code 600-xx 601-xx 602-xx 603-xx 604-xx 605-xx 606-xx 607-xx 608-xx 609-xx 610-xx 699-xx Description Diskette ID drive types test failed. Diskette format failed. Diskette read test failed. Diskette write/read/compute test failed. Diskette random seek test failed. Diskette ID media failed. Diskette speed test failed. Diskette wrap test failed. Diskette write protect test failed. Diskette reset controller test failed. Diskette change line test failed. Diskette drive/media ID error. Recommended Action The following steps apply to error codes 600-xx through 610-xx. 1. Replace the diskette and retest. 2. Check and/or replace the diskette power and signal cables and retest. 3. Replace the diskette drive and retest. 4. Replace the system board and retest. 1. Replace the media and retest. 2. Run the System Configuration Utility and retest.