Dell PowerEdge R510 Hardware Owner's Manual - Page 106
If applicable, remove the cooling shroud. See Removing the Cooling
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
1 Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 2 Open the system. See "Opening the System" on page 87. 3 If applicable, remove the cooling shroud. See "Removing the Cooling Shroud" on page 90. 4 Disconnect the fan's power cable from the system board. See Figure 3-16. NOTE: To remove fans 3 and 4, remove the storage controller card first. See "Removing the Storage Controller Card" on page 129. NOTE: To remove fan 5 in the twelve-hard-drive systems, remove the internal hard drive bay and carrier. See "Removing an Internal Hard Drive Bay" on page 99. 5 Press the release tab while grasping the ends of the fan and lift the fan straight up from the fan bracket. See Figure 3-15 and Figure 3-16. 106 Installing System Components