Dell PowerEdge R510 Hardware Owner's Manual - Page 32
Check CPU or, E141C Unsupported - technical guide
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Code Text Causes Corrective Actions E1410 System Fatal Error detected. Specified processor has an Remove AC power to the internal error. The error system for 10 seconds and may or may not have restart the system. been caused by the processor. If the problem persists, see "Getting Help" on page 199. E1414 CPU # temp exceeding range. Check CPU heatsink. Specified processor is out of acceptable temperature range. Ensure that the processor heat sinks are properly installed. See "Troubleshooting Processors" on page 186 and "Troubleshooting System Cooling Problems" on page 176. E1418 CPU # not detected. Check CPU is seated properly. Specified processor is missing or bad, and the system is in an unsupported configuration. Ensure that the specified processor is properly installed. See "Troubleshooting Processors" on page 186. E141C Unsupported Processors are in an CPU config. unsupported Check CPU or configuration. BIOS revision. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system's Getting Started Guide. E141F CPU # protocol The system BIOS error. Power has reported a processor cycle AC. protocol error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 199. 32 About Your System