Dell PowerEdge R510 Hardware Owner's Manual - Page 43
Alert! Node, Installation Guidelines - idrac6
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Message Causes Corrective Actions Alert! iDRAC6 not The optional iDRAC6 is not Wait for the system responding. responding to BIOS to reboot. Rebooting. communication either because it is not functioning properly or has not completed initialization. The system reboots. Alert! iDRAC6 not The optional iDRAC6 responding. has hung. Power required may exceed PSU wattage. The optional iDRAC6 was remotely reset while system was booting. Alert! Continuing system boot accepts the risk After AC recovery, the optional iDRAC6 takes longer than normal to boot. that system may power down without warning. Remove AC power to the system for 10 seconds and restart the system. Alert! Node Interleaving disabled! Memory configuration does not support Node Interleaving. The memory configuration does not support node interleaving, or the configuration has changed (for example, a memory module has failed) so that node interleaving cannot be supported. The system still runs, but without node interleaving. Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 115. If the problem persists, see "Troubleshooting System Memory" on page 177. About Your System 43