Dell PowerEdge R510 Hardware Owner's Manual - Page 33
CPU Bus parity, Power Supply - error codes
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Code Text Causes Corrective Actions E1420 CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 199. E1422 CPU # machine check error. Power cycle AC. The system BIOS has reported a machine check error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 199. E1610 Power Supply # (### W) missing. Check power supply. Specified power supply was removed or is missing from the system. See "Troubleshooting Power Supplies" on page 175. E1614 Power Supply # Specified power supply (### W) error. has failed. Check power supply. See "Troubleshooting Power Supplies" on page 175. E1618 Predictive failure on Power Supply # (### W). Check PSU. An over-temperature condition or power supply communication error has caused the predictive warning of an impending power supply failure. See "Troubleshooting Power Supplies" on page 175. E161C Power Supply # Specified power supply (### W) lost is attached to the system, AC power. but it has lost its Check PSU AC input. cables. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 175. About Your System 33