Dell PowerEdge R510 Hardware Owner's Manual - Page 36
SAS cable B - usb 3 0
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Code Text Causes Corrective Actions E1A14 SAS cable A failure. Check connection. SAS cable A is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 199. E1A15 SAS cable B failure. Check connection. SAS cable B is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 199. E1A1D Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 199. E2010 Memory not No memory was detected detected. in the system. Inspect DIMMs. Install memory or reseat memory modules. See "Installing Memory Modules" on page 119 or "Troubleshooting System Memory" on page 177. E2011 Memory configuration failure. Check DIMMs. Memory detected, but is not configurable. Error detected during memory configuration. See "Troubleshooting System Memory" on page 177. E2012 Memory Memory configured, configured but but is unusable. unusable. Check DIMMs. See "Troubleshooting System Memory" on page 177. E2013 BIOS unable to The system BIOS failed shadow memory. to copy its flash image Check DIMMs. into memory. See "Troubleshooting System Memory" on page 177. 36 About Your System