Dell PowerStore 5000X EMC PowerStore Installation and Service Guide - Page 49

Install an SFP module, Verify the operation of a replacement part, Return a faulted part

Page 49 highlights

Example EMC3551 Figure 48. Removing an SFP module Install an SFP module Steps 1. Verify that the replacement SFP module has the same part number as the failed SFP module. The part number is on a label attached to the SFP module. 2. Push the spring release latch up and slide the new SFP module into the port until it is securely connected. EMC3550 Figure 49. Installing an SFP module 3. Push the spring release down to lock the SFP module into place. 4. Reconnect the cable to the replacement SFP module. Example Verify the operation of a replacement part Steps 1. From PowerStore Manager, select Hardware. 2. Select the appliance where you replaced the faulted part. 3. From the Hardware card, select the view of the system where the part was replaced. The status of the replacement part should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure that the part is correctly seated, or contact your service provider. Return a faulted part About this task For US customers, return defective material within five business days. For International customers, return defective material within 10 business days. The materials required to return your defective part are supplied with the good part shipment. Base enclosure service procedures 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Example
EMC3551
Figure 48. Removing an SFP module
Install an SFP module
Steps
1.
Verify that the replacement SFP module has the same part number as the failed SFP module.
The part number is on a label attached to the SFP module.
2.
Push the spring release latch up and slide the new SFP module into the port until it is securely connected.
EMC3550
Figure 49. Installing an SFP module
3.
Push the spring release down to lock the SFP module into place.
4.
Reconnect the cable to the replacement SFP module.
Example
Verify the operation of a replacement part
Steps
1.
From PowerStore Manager, select
Hardware
.
2.
Select the appliance where you replaced the faulted part.
3.
From the
Hardware
card, select the view of the system where the part was replaced.
The status of the replacement part should read
Healthy
. If the status is still
Faulted
, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the part is correctly seated, or contact your service provider.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material within 10
business days. The materials required to return your defective part are supplied with the good part shipment.
Base enclosure service procedures
49