Dell PowerStore 5000X EMC PowerStore Installation and Service Guide - Page 67

Do not remove any cables from the other node.

Page 67 highlights

Steps 1. Rotate the power cable retention bail to the left (right for top power supply). Disconnect the power cable from the power supply. NOTE: If the I/O module and network cables are not already labeled, label them clearly for reconnecting later. Figure 78. Removing the power cable 2. Disconnect the network and all other cables from the back of the I/O modules and network ports on the node. NOTE: Do not remove any cables from the other node. 3. Pull the orange release trigger while gently pushing in on the node. The hook disengages from the locking mechanism, and the release tab slides out. NOTE: The node comes completely out of the chassis. Be prepared to support the node to avoid dropping it. Figure 79. Disengaging the locking mechanism 4. Use the release handle to pull the node outward enough to grasp the sides with both hands. Then, with both hands supporting the node, pull the node fully out of the enclosure. Base enclosure service procedures 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Steps
1.
Rotate the power cable retention bail to the left (right for top power supply). Disconnect the power cable from the power supply.
NOTE:
If the I/O module and network cables are not already labeled, label them clearly for reconnecting later.
Figure 78. Removing the power cable
2.
Disconnect the network and all other cables from the back of the I/O modules and network ports on the node.
NOTE:
Do not remove any cables from the other node.
3.
Pull the orange release trigger while gently pushing in on the node.
The hook disengages from the locking mechanism, and the release tab slides out.
NOTE:
The node comes completely out of the chassis. Be prepared to support the node to avoid dropping it.
Figure 79. Disengaging the locking mechanism
4.
Use the release handle to pull the node outward enough to grasp the sides with both hands. Then, with both hands supporting the
node, pull the node fully out of the enclosure.