Digital halftoning AAS (Auto Area Segmentation, enable/disable selectable) 3 error diffusion modes (A, B, and C) 4 dither patterns (A, B, C, and D) for bi-level and quad-level data (2 downloadable dither patterns) Gamma correction 2 types for CRT display 3 types for printer 1 type user-defined Color correction 1 type for CRT display 3 types for printer (available in color byte sequence mode and color line sequence mode) 1 type user-defined Interfaces SCSI 2 (micro DB 50-pin connectors) USB (Type B receptacle connector) IEEE 1394 (FireWire), optional Light source Xenon gas cold cathode fluorescent lamp Reliability 100,000 cycles of carriage movement (main unit MCBF) Dimensions Width: Depth: 13 inches (332 mm) 22.1 inches (562 mm) Height: 5.3 inches (133 mm) Weight Approximately 18.7 lb (8.5 kg) Electrical Input voltage range 100 to 120 VAC: 220 to 240 VAC: 90 to 132 VAC 198 to 264 VAC Rated frequency 50 to 60 Hz Rated current 100 to 120 VAC: 0.8 A 220 to 240 VAC: 0.4 A Power consumption Operating: Approximately 30 W Approximately 50 W with TPU or ADF unit Standby: Approximately 10 W Environmental Temperature Operating: 41 to 95 °F (5 to 35 °C) 50 to 89 °F (10 to 32 °C when using ADF) Storage: -13 to 140 °F (-25 to 60 °C) Humidity (without condensation) Operating: 10 to 80% Standby: 10 to 85% Operating conditions Ordinary office or home conditions. Avoid dust, direct sunlight, and proximity to strong light sources. Safety Approvals 120 V model Safety: UL 1950 CSA C22.2 No. 950 EMC FCC part 15 subpart B class B CSA C108.8 class B 230 V model Safety: EN 60950 EMC: EN 550022 (CISPR Pub 22) class B AS/NZS 3548 class B 54 Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

54
Specifications
Digital halftoning
AAS (Auto Area Segmentation,
enable/disable selectable)
3 error diffusion modes (A, B, and C)
4 dither patterns (A, B, C, and D) for
bi-level and quad-level data
(2 downloadable dither patterns)
Gamma correction
2 types for CRT display
3 types for printer
1 type user-defined
Color correction
1 type for CRT display
3 types for printer (available in color
byte sequence mode and color line
sequence mode)
1 type user-defined
Interfaces
SCSI 2 (micro DB 50-pin connectors)
USB (Type B receptacle connector)
IEEE 1394 (FireWire), optional
Light source
Xenon gas cold cathode fluorescent
lamp
Reliability
100,000 cycles of carriage movement
(main unit MCBF)
Dimensions
Width:
13 inches (332 mm)
Depth:
22.1 inches (562 mm)
Height:
5.3 inches (133 mm)
Weight
Approximately 18.7 lb (8.5 kg)
Electrical
Input voltage range
100 to 120 VAC:
90 to 132 VAC
220 to 240 VAC:
198 to 264 VAC
Rated frequency
50 to 60 Hz
Rated current
100 to 120 VAC:
0.8 A
220 to 240 VAC:
0.4 A
Power consumption
Operating:
Approximately 30 W
Approximately 50 W
with TPU or ADF unit
Standby:
Approximately 10 W
Environmental
Temperature
Operating:
41 to 95 °F (5 to 35 °C)
50 to 89 °F (10 to 32 °C
when using ADF)
Storage:
–13 to 140 °F
(–25 to 60 °C)
Humidity (without condensation)
Operating:
10 to 80%
Standby:
10 to 85%
Operating conditions
Ordinary office or home conditions.
Avoid dust, direct sunlight, and
proximity to strong light sources.
Safety Approvals
120 V model
Safety:
UL 1950
CSA C22.2 No. 950
EMC FCC part 15
subpart B class B
CSA C108.8 class B
230 V model
Safety:
EN 60950
EMC:
EN 550022
(CISPR Pub 22) class B
AS/NZS 3548 class B