HP StorageWorks 2/32 SAN switch 2/32 version 4.0.2b release notes - Page 13

command and monitor the, switch IP address is now controlled by the new active CP card.

Page 13 highlights

Firmware Upgrade Procedures 7. Reissue the haShow command from the switch IP session, as follows: ter1_127:admin> haShow Local CP (Slot 6, CP0): Active. Remote CP (Slot 5, CP1): Non-Redundant ?This says the standby CP is still rebooting. ter1_127:admin> haShow Local CP (Slot 6, CP0): Active Remote CP (Slot 5, CP1): Standby haShow Local CP (Slot 6, CP1): Active

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Firmware Upgrade Procedures
13
SAN switch 2/32 Version 4.0.2b Release Notes
7.
Reissue the haShow command from the switch IP session, as follows:
ter1_127:admin> haShow
Local CP (Slot 6, CP0): Active.
Remote CP (Slot 5, CP1): Non-Redundant ?This says the standby CP
is still rebooting.
ter1_127:admin> haShow
Local CP (Slot 6, CP0): Active
Remote CP (Slot 5, CP1): Standby <- Standby CP has completed
rebooting and ready to become the active CP.
HA Enabled, Heartbeat Up
8.
From the switch IP address issue the
haFailover
command. This causes
the active CP card to failover to the standby CP card. The standby CP card
then becomes the active CP card, and the active CP card reboots and becomes
the standby CP card.
9.
It is necessary to re-telnet into the switch IP address due to the failover. The
switch IP address is now controlled by the new active CP card.
10.
Issue the
haShow
command and monitor the
haShow
command output,
which should look similar to the following:
ter1_127:admin> haShow Local CP (Slot 6, CP1): Active <----- The
active CP is now CP1.
Remote CP (Slot 5, CP0): Non-Redundant <----- This says the
original CP is still rebooting.
ter1_127:admin> haShow
Local CP (Slot 6, CP1): Active
Remote CP (Slot 5, CP0): Standby <------- CP0 is now ready to do
firmwareDownload.
HA Enabled, Heartbeat Up
When the reboot is complete the haShow output should look as
follows:
ter1_127:admin> haShow
Local CP (Slot 6, CP1): Active
Remote CP (Slot 5, CP0): Standby <------- CP0 is now ready to do
firmwareDownload.
HA Enabled, Heartbeat Up
11.
Telnet into the standby CP card (now CP0) and issue the
firmwareDownload
command. Make sure that both the reboot option and
the
firmwareCommi
t option are executed. It is NOT necessary to perform a