HP StorageWorks 2/32 SAN switch 2/32 version 4.0.2b release notes - Page 62
Recommended Steps, Documentation Anomalies, Feature/Option Configuration Callouts in Readme.txt
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Documentation Anomalies Recommended Steps Use these steps to determine if there is a hardware problem. 1. Determine which component is indicated. The message provides the information as follows: I2C timed out: state 2. Check the LEDs on the related hardware component. 3. Enter the switchstatusshow, chassisshow, and sensorshow commands. 4. Take the appropriate action. If one of the components appears to be faulted, try reseating the component. If it still appears to be faulty, replace the component. Note: If the LEDs and command printouts indicate that all components are healthy, then it was a transient I2C bus fault, and no action is required. Documentation Anomalies Feature/Option Configuration Callouts in Readme.txt The readme.txt file included on your software CD does not correctly identify available SAN Switch 2/32 feature/option configurations. Refer to Features Summary, page 6, of these Release Notes for current information. 62 SAN switch 2/32 Version 4.0.2b Release Notes