HP StorageWorks 8/80 Brocade Fabric OS Command Reference Manual v6.2.0 (53-100
HP StorageWorks 8/80 - SAN Switch Manual
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 8/80 manual content summary:
- HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 1
53-1001186-01 24 November 2008 Fabric OS Command Reference Manual Supporting Fabric OS v6.2.0 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 2
Fabric OS, File Lifecycle Manager, MyView, and StorageX are registered trademarks and the Brocade B-wing symbol, DCX, and SAN warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right .com/support/oscd. - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 3
San Jose, CA 95110 Tel: 1-408-333-8000 Fax Fabric OS Command Reference. Document Title Publication Number Summary of Changes Fabric OS Reference v2.0 53-0001487-03 Fabric OS Reference v2.2 53-0001558-02 Fabric OS Reference v2.3 53-0000067-02 Fabric OS Reference v3.0 53-0000127-03 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 4
Modified 1 command. Updated Preface and RBAC/AD table. August 2008 Added 14 new commands to support Logical Fabrics. Modified 34 commands with new command operands to support new Fabric OS v6.2.0 features. Removed 8 deprecated commands. Miscellaneous edits to ~45 commands to correct edits, update - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 5
xix Supported hardware and software xix What is new in this document xx Document conventions xxii Notice to the reader xxiv Additional information xxv Getting technical help xxv Document feedback xxvii Chapter 1 Using Fabric OS Commands In this chapter 1 Understanding role-based access - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 6
73 cfgShow 74 cfgSize 76 cfgTransAbort 78 cfgTransShow 79 chassisBeacon 80 chassisConfig 81 chassisEnable 82 chassisDisable 83 chassisName 84 chassisShow 85 cliHistory 87 configDefault 88 configDownload 90 configList 95 configRemove 96 vi Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 7
Fabric OS Command Reference 53-1001186-01 configShow 97 configUpload 101 configure 105 configureChassis 113 cryptoCfg 115 dataTypeShow 162 date 163 dbgShow 165 defZone 166 diagClearError 168 diagDisablePost 169 diagEnablePost 170 diagHelp 171 diagPost 172 diagRetry 173 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 8
fcrPhyDevShow 246 fcrProxyConfig 248 fcrProxyDevShow 250 fcrResourceShow 252 fcrRouterPortCost 254 fcrRouteShow 256 fcrXlateConfig 257 fddCfg 260 fdmiCacheShow 262 fdmiShow 263 ficonClear 264 ficonCupSet 265 viii Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 9
Fabric OS Command Reference 53-1001186-01 ficonCupShow 267 ficonHelp 269 ficonShow 270 fipsCfg 276 firmwareCommit 279 firmwareDownload 280 firmwareDownloadStatus 285 firmwareKeyShow 288 firmwareKeyUpdate 289 firmwareRestore - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 10
407 iscsiSwCfg 409 islShow 410 isnscCfg 411 itemList 413 killTelnet 415 ldapCfg 416 lfCfg 418 licenseAdd 422 licenseHelp 423 licenseIdShow 424 licensePort 425 licenseRemove 427 x Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 11
Fabric OS Command Reference 53-1001186-01 licenseShow 428 linkCost 429 login 431 logout 432 lsanZoneShow 433 lsCfg 435 lsDbShow 440 fosExec 443 memShow 445 msCapabilityShow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 12
554 portCfgCreditRecovery 556 portCfgDefault 557 portCfgEport 558 portCfgEXPort 559 portCfgFportBuffers 562 portCfgGport 563 portCfgISLMode 564 portCfgLongDistance 566 portCfgLport 569 portCfgNPIVPort 571 portCfgNPort 573 xii Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 13
Fabric OS Command Reference 53-1001186-01 portCfgPersistentDisable 574 portCfgPersistentEnable 575 PortCfgQos 576 portCfgShow 578 portCfgSpeed 585 portCfgTrunkPort 586 portCfgVEXPort 587 portCmd 590 portDebug 594 portDisable - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 14
secPolicyDump 699 secPolicyFCSMove 702 secPolicyRemove 704 secPolicySave 706 secPolicyShow 707 secStatsReset 709 secStatsShow 711 sensorShow 713 setContext 714 setDbg 715 setModem 716 setVerbose 717 xiv Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 15
Fabric OS Command Reference 53-1001186-01 sfpShow 718 shellFlowControlDisable 722 shellFlowControlEnable 723 slotPowerOff 724 slotPowerOn 725 slotShow 726 SnmpConfig 730 spinFab 737 sshUtil 740 statsClear - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 16
836 zoneCreate 837 zoneDelete 839 zoneHelp 840 zoneObjectCopy 841 zoneObjectExpung 842 zoneObjectRename 843 zoneRemove 844 zoneShow 845 Primary FCS commands Primary FCS commands 847 xvi Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 17
Appendix A Appendix A: Command availability In this appendix 849 Command validation checks 849 Encryption commands and permissions 850 General Fabric OS commands and permissions 852 Fabric OS Command Reference xvii 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 18
xviii Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 19
xix •Supported hardware SAN and Brocade switches. • Chapter 2, "Fabric OS Commands" provides command information. • Chapter 3, "Primary FCS commands" summarizes the subset of commands available when an FCS policy is enabled. • Appendix A, "Appendix A: Command availability," explains the Role-Based - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 20
Backbone • Brocade Encryption Switch • Blades: FA4-18, FC4-16, FC4-16IP, FC4-32, FC4-48, FC10-6, FR4-18i, FC8-16, FC8-32, FC8-48, FS8-18 Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS v6.2.0, documenting all - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 21
operands to support Logical Fabrics. • configure - New operands to configure port area, XISL use, and disable FID check. This command now only configures switch configuration. There is a new command to configure chassis parameters (configureChassis). • cryptoCfg - New operands to support HP SKM key - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 22
behavior in Virtual Fabrics, and to fix documentation errors. The following commands have been deprecated. Help pages have been removed from the Command Reference manual. Help pages on the switch display a message stating that the commands are no longer supported. • bladeBeacon - Use switchBeacon - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 23
of this guide are presented in mixed letter case, for example, switchShow. In examples, command letter case is all lowercase. If there are exceptions, this manual specifically notes those statement indicates potential damage to hardware or data. Fabric OS Command Reference xxiii 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 24
that can cause damage to hardware, firmware, software, or data. DANGER A to Brocade and Fibre Channel, see the Brocade Glossary. For definitions of SAN-specific terms, Trademarks and Products Commvault EMC HP IBM Legato Microsoft Corporation NetApp Sun Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 25
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 26
problem, including the switch or fabric behavior immediately • following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number The switch serial number - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 27
, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. Fabric OS Command Reference xxvii 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 28
xxviii Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 29
. TABLE 1 Role definitions Role Name Definition User Non-administrative use, such as monitoring system activity. In Fabric OS v6.2.0, the user account gains access to Fabric ID 128. This is the default Logical Fabric after a firmware upgrade. Operator A subset of administrative tasks - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 30
be executed in any switch context. Base Switch Only Command can be executed only on the base switch. Default Switch Only Command can be executed only on the default switch. N/A Command is a chassis command or not supported in Virtual Fabric mode. In a Virtual Fabric environment where contexts - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 31
in this manual. Using the command line interface The Fabric OS command line interface (accessed via Telnet, SSH, or serial console) provides full management capability on a Brocade switch. The Fabric OS CLI enables an administrator to monitor and manage individual switches, ports, and entire - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 32
1 Using the command line interface • Access to the full range of Fabric OS features, given the license keys installed. • Assistance with configuration, monitoring, dynamic provisioning, and daily management of every aspect of storage area networks (SAN). • A deeper view of the tasks involved in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 33
(AAA) services. Use this command to display, add, remove, change, enable or disable the RADIUS or LDAP configuration. Switches running Fabric OS v5.2.0 or later use a local as well as a remote authentication mechanism for validating a login. Supported authentication protocols include Password - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 34
can use centralized RADIUS servers to manage AAA services for a switch, as defined in the RFC 2865 RADIUS specification. Fabric OS v6.1.0 or later is required to configure LDAP while in FIPS mode. Refer to the Fabric OS Administrator's Guide for configuration procedures. This command can be executed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 35
enclosed in double quotation marks. The following AAA services and service pairs are valid: "local" Default setting. Authenticates the user against the local database only. If the password does not match or the user is not defined, the login fails. Fabric OS Command Reference 7 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 36
credentials are correct, the user authentication succeeds. If the user provides credentials from the switch database, the RADIUS authentication fails but login succeeds through the switch database. Enables the current LDAP configuration as the primary AAA service and the switch-local database as the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 37
See Also To replace the AAA service with backup option: switch:admin> aaaconfig --authspec "ldap;local" -backup none aaaConfig 2 Fabric OS Command Reference 9 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 38
this command changes only the Defined Configuration in the transaction buffer. The -- default zone mode to "No Access" execute the following command sequence: switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave Refer to defZone help for more information. 10 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 39
supported: --activate arg Activates an Admin Domain. An Admin Domain is enforced only if it is in an activated state. AD0 is always in an activated state. By default, after the Admin Domain is enabled the defined configuration and enforces the defined configuration on all switches in the fabric. ad - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 40
operation to succeed. Not all existing user sessions to a deleted Admin Domain are number. The rename operation remains in the transaction buffer until you issue ad --apply or ad --save. --save Saves the outstanding Admin Domain transaction to the defined configuration on all switches in the fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 41
, all Admin Domain information from the transaction buffer, defined configuration and effective configuration is displayed. --validate arguments Checks whether Admin Domain members are from a non-Admin Domain aware switch or the members do not exist in the fabric. The output is similar to ad --show - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 42
a number. For ad --create, both name and number can include: • Supports node or port WWNs. • End-device members, switch. Any switch member specified in Domain ID format is converted into a switch WWN based on the current fabric information. Operations with switch list fail if the domain ID to switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 43
,5; 4,1" To apply all changes made to the Admin Domain configurations since --apply was last executed: switch:admin> ad --apply You are about to enforce the saved AD configuration. This action will trigger ad --apply to all switches in the fabric. Do you want to apply all admin domains (yes, y, no - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 44
only save the changes to Defined configuration. Any changes made will be enforced only on ad --apply. Do you want to save admin domains (yes, y, no, n): [no] y To select a new Admin Domain context by specifying the AD number: switch:admin> ad --select 12 16 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 45
: AD255 Defined configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; 1,12; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 46
2 ad 18 To display the Admin Domain effective configuration information: switch:admin> ad --show -m 2 Current AD: 255 : AD255 Effective configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 47
:17:00:00; 10:00:00:00:00:15:00:00; 10:00:00:00:00:07:00:00; Effective configuration AD Number: 50 AD Name: AD50 State: Active Device WWN members: Switch port members: 10:00:00:00:00:17:00:00; 10:00:00:00:00:15:00:00; 2,52; 2,53; 2,54 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 48
See Also To display the current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout. 20 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 49
• Add or delete N_Ports in Port group. • Display all policies and their status. • Enable or disable Auto Port configuration policy. • Enable or disable preferred Secondary N_Port policy. • Enable, disable, and manage Advanced Device Security (ADS) policy. Fabric OS Command Reference 21 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 50
in a port group. Auto Port Configuration (auto): When this policy is enabled, the AG enabled switch automatically detects available ports and map F_Ports to N_Ports. Auto Port Configuration is disabled by default. Advanced Device Security (ADS) policy. This policy restricts access to the Fabric at - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 51
. All F_Port to N_Port mapping and port group configurations are ignored. ads Enables the advanced device security (ADS) policy. When enabled, this policy applies to all the ports on the switch. By default all devices have access to the fabric on all ports. --policydisable policy Disables the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 52
port group. The N_Ports in the Port Group that was deleted are moved to the default Port Group, which is pgid 0. --failoverenable N_Port Enables the failover policy for a given N_Port. When failover policy is enabled as enabled (1) or disabled (0). 24 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 53
before a secondary N_Port can be configured. The list of F_Ports to be mapped must be enclosed in quotation marks. Port numbers must be separated by semicolons. -- list ("") indicates no access. ADS policy must be enabled for this command to succeed. Fabric OS Command Reference 25 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 54
1e:35:9b:e7 Number of Ports : 16 IP Address(es) : 10.115.74.53 Firmware Version : v6.0.0 N_Ports : 4 F_Ports : 10 Policies enabled : pg Port Group information : PG_ID PG_Members PG_Name 0 1;3 pg0 2 0;2 SecondFabric Fabric Information : Attached Fabric Name N_Ports 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 55
--policyeanble auto All Port related configurations will be lost. Please save the current configuration using configupload. Do you want to continue? (yes, y, no, n): [no] y 5. To disable auto policy when the switch is disabled: switch:admin> ag --policydisable auto Default factory settings will be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 56
- Failover and Failback indicate whether or not N_Port policy is enabled (1) or disabled (0). - PG_ID is the Port Group ID and PG_Name is the Port Group Name. 2. To clear all F_Ports mapped to the configured primary N_Port 0: switch:admin> ag --mapset 0 "" F_Port to N_Port mapping has been updated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 57
0 Failover on N_Port 0 is not supported switch:admin> ag --failbackdisable 2 Failback policy is disabled for port 2 admin> ag --failbackshow 2 Failback on N_Port 2 is not supported switch:admin> ag --failbackenable 2 Failback policy is enabled for port 2 ag 2 Fabric OS Command Reference 29 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 58
ag --failbackenable 2 Failback policy is enabled for port 2 switch:admin> ag --failbackenable 3 Failback on N_Port 3 is not supported switch:admin> ag --failbackenable 2 Failback on N_Port 2 is supported Port Group commands 1. To display Port Group information: switch:admin> ag --pgshow PG_ID - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 59
port mapping for F_Ports 7, 8 and 9: switch devices for Ports 11 and 12 to 'no access': switch:admin> ag for Ports 1, 10 and 13 to 'all access': switch:admin> of allowed devices for ports 1 and 9: switch:admin> ag --adsdel lists of allowed devices for ports 1 and 9: switch:admin> ag --adsadd "3;9" - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 60
2 ag See Also 4. To display the lists of allowed devices on the switch: switch:admin> ag--adsshow F_Port WWNs Allowed 1 ALL ACCESS 3 20:03:08:00:88:35: ACCESS 11 NO ACCESS 12 NO ACCESS 13 ALL ACCESS portCfgNPort, portCfgNPIVPort 32 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 61
F_Ports and the configured N_Ports in the Access Gateway attached to the fabric shows the following information. Name The name of the Access Gateway. Ports The number of ports in the Access Gateway. Enet IP Addr The IP address of the Access Gateway. Firmware Current firmware running on the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 62
/Remote Name 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 See Also To display all Access Gateways attached to the fabric: switch:admin> agshow Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:02:b7:2c 16 10.32.173.62 v6 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 63
change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with cfgSave. Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 64
change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 65
change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 66
change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 67
to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands When invoked without operand, this command displays all zone configuration information (defined and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 68
default policy. Distributed path selection (DSP) is supported in logical fabrics. APT policy settings affecting the DPS behavior can be configured per logical switch, and settings apply to the partition for which they are set. Note that policy settings for the base switch or any switch in the base - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 69
Refer to dlsSet for the definition of a fabric event. This policy does not support static routes. DLS is always enabled and the DLS setting cannot change with this policy. Specifies an additional AP policy option supported under both port-based and exchange-based policies. The following policies are - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 70
2-SECURITY, 3-CONFIGURATION, 4-FIRMWARE and 5-FABRIC filters. This operand is required. --severity severity_level Sets audit severity level. When severity is set, only log messages of type severity_level and higher are displayed. Valid values are INFO, WARNING, ERROR, and CRITICAL. By default, all - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 71
See Also switch:admin> auditcfg --show Audit filter is disabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC Severity level: INFO auditDump auditCfg 2 Fabric OS Command Reference 43 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 72
started. 2 AUDIT, 2008/08/11-13:17:30 (UTC), [SULB-1003], INFO, FIRMWARE, NONE/NONE/NONE/None/CLI, None/sw48000_100/FID CHASSIS, , Firmwarecommit has started. [output truncated] To clear the audit log: switch:admin> auditdump -C See Also auditCfg 44 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 73
, if applicable, used on the port. Authentication parameters are set on a per-switch basis. If Virtual Fabrics are enabled, all authentication parameters apply to the current logical switch context only, and must be configured separately for each logical switch. Use setcContext to change the current - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 74
system for FIPS. Refer to the Fabric OS Administrator's Guide for details on FIPS configuration. --policy Sets the switch authentication policy or device authentication policy. The following options are supported: -sw on|off|active|passive Sets the switch authentication policy. Specify one of the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 75
specifying the port number. allE Specify all E_Ports in the switch. Examples To display authentication configuration on the switch: switch:admin> be segmented during next E-port bring-up. ARE YOU SURE (yes, y, no, n): [no] y Auth Policy is set to ACTIVE Fabric OS Command Reference 47 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 76
to ON 2008/03/24-23:13:06, [AUTH-1003], 112,, INFO, Stealth_3, Device authentication type has been successfully set to ON To start authentication on E/F_Ports 2, 3, and 4: switch:admin> authutil --authinit 2,3,4 To disable md5 hash type for FIPS configuration: switch:admin> authutil --show AUTH - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 77
banner for a switch: switch:admin> bannerset "My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 78
that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 79
In this example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. See Also portRouteShow Fabric OS Command Reference 51 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 80
when the blade is faulted, powered off, or running diagnostics. If Virtual Fabrics are not enabled on the switch, and slotShow is issued after a blade has been disabled, the blade is displayed as ENABLED (User Ports disabled) as shown in the example below. When executing bladeDisable in Virtual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 81
Use bladeEnable to re-enable the blade after making configuration changes or running offline diagnostics. If the switch is connected to a fabric through previously disabled ports, it rejoins the fabric. If this switch remains the principal switch at the end of the fabric countdown, it assigns itself - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 82
VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, chassisDisable, chassisEnable, portEnable, portDisable, switchDisable, switchShow 54 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 83
High Availability (HA). This command is currently supported only on the Brocade Encryption platform at a default speed of 4 Gbps and a loopback mode of 7. Use portLoopBackTest on all other platforms. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 84
Rx Fifo Info: Vader port 4 recovering Rx Fifo Info: Vader port 5 recovering Rx Fifo Ob1 portloopbacktest on ports 80-90 PASSED Test Complete: bpportloopbacktest Pass 1 of 1 Duration 0 hr, 0 min & 24 sec (0:0:24:599). Cleaning up after test....... passed. 56 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 85
. PORTDIED A previously initialized port went to an un-initialized state. STATS Errors were found in the ASIC statistics. TIMEOUT Did not receive a frame in the given timeout period. XMIT Frame transmission failure. See Also itemlist. portLoopbacktest Fabric OS Command Reference 57 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 86
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: -passcnt count Specifies the number of test repetitions. By default the test runs once. -bpports itemlist Specifies a list of blade ports to test. By - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 87
details. Operands The following operand is required: slotnumber Specify a nonzero value for the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot 2: switch:admin> burninerrclear 2 See Also burninErrShow Fabric OS Command Reference 59 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 88
. Operands The following operand is required: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear 60 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 89
port-count products, this is the chassis-persistent storage. The behavior of this command is determined by the manner in which the diagnostics daemon is configured in level: switch:admin> burninlevel -show Burnin level is 0. See Also burninErrShow, diagDisablePost, diagEnablePost Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 90
or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands The following operands are optional: --slot slotnumber Specify a slot number to get the burn-in status of a single slot. If no slot is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 91
is currently in effect. The devices that an initiator sees are based on this configuration. The effective configuration is built when a specified zone configuration is enabled. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 92
the change to take effect, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 93
a zone configuration is enabled, you are warned to first disable the enabled zone configuration or to provide a valid configuration with the same configuration in nonvolatile memory for all the switches in the fabric. If no current zoning configuration exists, use the cfgSave command. If the default - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 94
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "cfgName" Specify a name for the zone configuration in double - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 95
to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 96
current zone configuration: switch:admin> cfgdisable You are about to disable zoning configuration. This action will disable any previous zoning configuration enabled. Do you want to disable zoning configuration? (yes, y, no, n): [no] y See Also cfgClear, cfgEnable, cfgSave 68 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 97
"Using Fabric OS commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operand is required: cfgName Specifies the name of the zone configuration. Examples To enable the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 98
safe zoning feature or the McDATA default zoning feature. Enabling or disabling safezoning or default zoning on one switch in the fabric enables or disables the specific feature fabric-wide, meaning that the feature is disabled or enabled on all switches in the fabric. Notes The execution of this - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 99
to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 100
in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To save a zone configuration: switch:admin> cfgsave You are about to save - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 101
is only effective when the Brocade switch/director is in McDATA fabric mode. Operands The cfgSaveActiveToDefined command has no operands. Examples Execute the cfgShow command to view defined and effective zoning configurations. switch:admin> cfgShow Default Zone: OFF Safe Zone: OFF Defined - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 102
sees in the fabric are based on this configuration. The effective configuration is built when a specific zone configuration is enabled and all error checking has been completed successfully. When this command is executed after a zoning transaction was aborted on the local switch, it displays - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 103
20:37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgTransAbort, cfgTransShow Fabric OS Command Reference 75 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 104
the zone configuration to all switches in the fabric. Committed size Displays the size of the defined configuration currently stored in Fabric OS commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 105
buffer size - 0 bytes AD Database Size: committed - 3124 bytes transaction - 0 bytes Number of ADs in Effective Configuration - 4 Each AD's Zone Database Size: cfgsize Info for AD Number:0 committed - 242 bytes transaction - 0 bytes (AD Name: AD0, State=Active): cfgsize - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 106
without committing it. All changes made since the transaction was started are removed and the zone configuration database is restored to the state before the transaction was started. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 107
Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. When an FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands none Examples To display the current transaction - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 108
the current value is displayed. Examples To turn chassis beaconing mode on: switch:admin> chassisbeacon 1 Chassis beacon success 1 See Also To turn beaconing mode off: switch:admin> chassisbeacon 0 Chassis beacon success 0 switchShow, switchbeacon 80 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 109
be implemented with caution. User account data and passwords might not be saved with configUpload. User accounts created with the userConfig command are deleted and user accounts are reset to factory defaults. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 110
command to enable a Virtual Fabric-aware chassis. All Fibre Channel ports that passed the power-on self test (POST) are enabled. They may come online if connected to a device, or remain offline if disconnected. Use chassisEnable to re-enable the chassis after making configuration changes or running - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 111
Virtual Fabric-aware chassis. All Fibre Channel ports are taken offline. This command prompts for confirmation unless the -force option is used. If the chassis is partitioned into logical switches that are part of logical fabrics, the remaining switches in these fabrics reconfigure. As each port is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 112
, numbers, underscore or hyphen characters. Spaces are not permitted. This operand is optional; if omitted, the current chassis name displays. Examples To change the chassis name to "dilbert": switch:admin> chassisname dilbert switch:admin> chassisname dilbert See Also switchName 84 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 113
Power Consume Factor: -xxx 5 Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx 6 Serial number (up to 12 characters): Factory Serial Num: xxxxxxxxxx 7 FRU of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 114
switch: switch:user> chassisshow Chassis Backplane Revision: 1C SW BLADE Slot: 3 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID: Part 2001 88 days 16 days See Also slotShow 86 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 115
the switch: • Timestamp • Username • IP address of the Telnet session • Options • Arguments This command displays the local CLI command history. The information is saved as part of supportSave as the CH file. It is also saved persistently to compact flash if the switch panics. The maximum number of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 116
FID | -chassis |-all] Use this command to reset the non-persistent configuration settings to their factory defaults. Beginning with Fabric OS v6.2.0, configuration data is grouped into chassis information and switch information. Each configuration type is managed separately. For information on file - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 117
FID Specifies the Fabric ID of the logical switch for which to reset the configuration. This operand is valid only in Virtual Fabric mode, and the executing account must have chassis permissions. -chassis Restores the non-persistent chassis configuration to factory defaults. This command requires - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 118
is not accepted by a switch running pre-v6.2 firmware. A v6.1 configuration downloaded to a 6.2 system is applied only to the default switch or chassis. For more information on compatibility refer to the Fabric OS Administrator's Guide. The switch must be disabled for configuration download of all - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 119
parameters. - Downloading a configuration file from a system that is not Virtual Fabric-capable to a system in Virtual Fabric mode is not recommended. The configuration is applied to the default switch only, and only to the ports that are part of the default switch. If an FCS policy is enabled, the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 120
allows you to effectively swap logical switch configurations. Note that all ports in the FID are reset to the default state when downloading data from the source FID. -chassis "host" "user" "path" Downloads the chassis configuration only. Specifies the name or the IP address of the external host - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 121
-fid 8 -USB config.txt To download switch configurations belonging to a logical switch with FID 4 to a logical switch with FID 8 from an attached USB device (requires chassis permissions): switch:admin> configdownload -fid 8 -sfid 4 -USB config_fid8.txt Fabric OS Command Reference 93 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 122
2 configDownload Diagnostics The configuration download may fail for one or more of the following reasons: • The switch has not been disabled. Disabling the switch is not necessary for configuration files containing only certain SNMP or Fabric Watch parameters. You may wish to attempt - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 123
a list of configuration files stored on the local chassis: switch:admin> configlist -local config.txt config2.txt next_cfg.txt 25679 25679 20977 2007 Jan 02 15:16 2007 Jan 06 15:16 2007 Jan 18 15:16 See Also configDownload, configUpload, configShow, configRemove Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 124
-local first_config.txt To remove a configuration file from an attached USB device without specifying a filename: switch:admin> configremove -USB File Name [config.txt]: second_config.txt See Also configDownload, configUpload, configList, configShow 96 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 125
not supported. Some configuration settings do not display when filtered. When in doubt, use the command without the -pattern operand. -all -fid FID Displays all configuration data including chassis and switch configuration. Displays configuration data for a logical switch specified by its fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 126
. Examples To display all configuration data on a Virtual Fabric-enabled system: switch :admin> configshow -all [Configuration upload Information] Configuration Format = 2.0 date = Tue Oct 7 14:54:20 2008 FOS version = v6.2.0.0 Number of LS = 3 [Chassis Configuration Begin] [fcRouting] fcRoute - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 127
111 ipfilter.1.rule.6:0,0x23,0,0,6,80 ipfilter.1.rule.7:0,0x23,0,0,6,443 ipfilter.1.rule.8:0,0x23,0,0,17,161 ipfilter.1.rule.9:0,0x23,0,0,17,111 ipfilter.1.state:3 ipfilter.1.type:1 [output truncated] To filter the content to display only the password configuration: switch :admin> configshow -all - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 128
Number of LS = 3 [Switch Configuration Begin : 0] SwitchName = Spirit_66 Fabric ID = 20 [Boot Parameters] boot.name:Spirit_66 boot.ipa:10.32.228.66 boot.licid:10:00:00:05:1e:41:5c:c1 boot.mac:10:00:00:05:1e:41:5c:c1 boot.device:eth0 boot.gateway.ipa:10.32.224.1 [Configuration] acl.clear:0 ag.port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 129
, not the upload. You can download a v6.1 configuration to a switch running v6.2 firmware, but a v6.2 configuration file is not accepted by a switch running pre-v6.2 firmware. For more information on compatibility, refer to the Fabric OS Administrator's Guide. The configuration file is divided into - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 130
format version, switch firmware version, time stamp, and number of logical switches. This section is the same in the switch configuration file. [fcRouting] Contains the Fibre Channel Router configuration. [chassis configuration] Contains configuration parameters relating to passwords, SNMP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 131
, the protocol defaults to FTP. -fid FID Uploads switch configuration data from a logical switch specified by its fabric ID. This parameter in valid only in a Virtual Fabric environment and requires chassis permissions. -chassis Uploads chassis configuration only. -all "host" "user" "path - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 132
To upload the switch configuration interactively from a switch that is not enabled for Virtual Fabrics: switch:admin> configupload Protocol (scp, ftp, local) [ftp]: Server Name or IP Address [host]: 192.168.38.245 User Name [user]: jdoe File Name [config.txt]: Password: configUpload complete: All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 133
with the configure command: • Switch fabric parameters • Virtual channel parameters • F_Port login parameters • Zoning operation parameters • Remote State Change Notifications (RSCN) transmission mode • Arbitrated Loop parameters • System Services settings • Portlog Events enable or disable settings - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 134
be in agreement among all switches to allow formation of the fabric. Table 2 lists the switch fabric settings that can be modified. TABLE 2 Configure command fabric parameters (* = multiplication symbol) Field Type Default Range Domain Allow XISL Use Enable a 256 Area Limit R_A_TOV E_D_TOV - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 135
supported only on Virtual Fabric-aware platforms under the following conditions: Virtual Fabrics must be enabled on the switch, and the switch cannot be a base switch. In addition, on the Brocade DCX or DCX-4S the switch cannot be a default switch, include interchassis link (ICL) ports or GigE ports - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 136
By default, the switch can send Class F frames. When this option is turned on, Class F traffic is converted to Class 2 traffic before being transmitted. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available for per-frame-based - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 137
configure 2 Virtual Channel Settings The switch enables fine-tuning for a specific application by configuring the parameters for eight virtual channels. The first two virtual channels are reserved for switch internal functions and are not available for modification. The default virtual channel - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 138
-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode values are as follows: 0 RSCN only contains single PID 1 RSCN contains multiple PIDs 2 Fabric addresses RSCN Domain RSCN to End-device for switch IP address or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 139
attributes are enabled. TABLE 9 Configurable application attributes Application File Type Default Range ssl rpcd Webtools Certificate File CA Certificate File Length of crypto key Secure RPCd Callback secret Basic User Enabled Perform License Checking and Warning Allow Fabric Event - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 140
2 configure switch:admin>configure Configure... Change fabric parameters? Y Change domain[30]: Allow XISL Use [no]: yes Enable a 256 Area Limit[0]: R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000.. 5000) [2000] WAN_TOV: (0..30000) [0] MAX_HOPS: (7..19) [7] Data field size: (256..2112) [2112] Sequence - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 141
attributes that may be modified. TABLE 10 Configurable application attributes Application File Type Default Range cfgload Enforce secure Config Upload/Download boolean no Enforce signature validation for firmware boolean no no/yes no/yes Fabric OS Command Reference 113 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 142
configurable on a Virtual Fabric-aware switch. TABLE 11 System settings Field Type Default Range system.blade.bladeFaultOn Number causes the problem blade to be powered off. Examples To enable signature validation for downloading firmware: switch:admin> configurechassis Configure... cfgload - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 143
corruption. If you are configuring multi-path LUNs as part of a HA cluster or DEK cluster or as a standalone LUN accessed by multiple hosts, follow the instructions described in the section "Configuring a multi-path Crypto LUN" in the Fabric OS Encryption Administrator's Guide. Note The execution - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 144
• Enabling or disabling an encryption engine (EE). • Encryption group member node and group leader registration. • Group-wide policy configuration. • Zeroization of all critical security parameters on the local encryption switch or blade. • Certificate display and management. Note The initial setup - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 145
encryption engine before configuration options may be set and encryption may be enabled. This command prompts User certificate are registered with the specified encryption engine. Specifies the slot number of the encryption engine to be registered. This operand is required on bladed systems. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 146
Specifies the IP address of the host to which the file is to be exported. To specify the host by name, it must first be configured with dnsconfig. host_username Specifies the user name for the host. Depending on your host configuration, the command may prompt for a password. 118 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 147
must be performed for all nodes that participate in a two-way certificate exchange-based authentication mechanism with key vaults. Fabric OS v6.2.0 supports two-way certificate exchange only for the HP SKM key vault. -CPcert Exports the member node CP certificate. --import Imports a certificate - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 148
the imported file. This is a user-generated file name. source_filename Specifies the name with the group leader: member_node_WWN Specifies the switch world wide name of the member node. IP address of the NetApp LKM appliance. This operand is required. 120 Fabric OS Command Reference 53-1001186- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 149
IP address of the NetApp LKM appliance. This operand is required. Zeroizes all critical security parameters on the local encryption switch Displays node configuration information. This manual cryptocfg --set -hbmisses value cryptocfg --set -hbtimeout value cryptocfg --add -membernode node_WWN Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 150
are part of the same encryption group. Fabric OS v6.2.0 supports up to four nodes per encryption group, and up to two encryption engines per node. The maximum number of EEs per encryption group is eight. With the exception of the --help and --show commands, all group configuration functions must - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 151
The node is part of the encryption group. DISCOVERING = The node is in the process of discovery. - Role: GroupLeader or MemberNode - IP address: Node IP address - Certificate: Node CP certificate name (user-defined) - Current master key (or link key) state: Not configured, Saved, Created, Propagated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 152
, the same subnet, and the same VLAN. Configure the GbE Ports (I/O sync links) with an IP address for the eth0 Ethernet interface, and also configure a gateway for these I/O sync links. Refer to the ipAddrSet help page for instructions on configuring the Ethernet interface. These I/O sync link - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 153
In the case of the HP SKM, this operand specifies the a host name or IP address. primary | secondary enabled by default. manual Enables manual failback. In this mode, failback must be initiated manually after an encryption switch or blade that failed earlier has been restored or replaced. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 154
set in conjunction with the time-out value. It must be configured at the group leader node and is distributed to all member nodes in the encryption group. The following operand is required: Specifies the number of heartbeat misses. The default value is 3. The range is 1-15 in integer increments only - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 155
CryptoTarget container and Crypto LUN configurations from this node prior to default this command backs up the key to the attached key vaults, or optionally to a predetermined file on the switch the alternate position to enable decryption of older data Fabric OS Command Reference 127 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 156
belong to the same encryption group and be part of the same fabric. Failure to ensure that HA cluster members are part of the same encryption group dissolves the HA cluster and the encryption engines lose their failover capability. The HA cluster configuration must be performed on the group leader - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 157
configuration. When invoked on the group leader, both defined and committed configuration data is displayed including the following: • Encryption group name: user-defined name • Number nodes' IP addresses for the GbE Ports (I/O sync ports) are not configured. The following operands are supported: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 158
slot_number Specifies the node WWN of the switch or chassis to which the encryption engine belongs. Specifies the encryption engine slot number on bladed systems. --remove -haclustermember Removes one or both encryption engine members from an already configured HA cluster. This command is valid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 159
2 Function 4. Storage device configuration and management Synopsis cryptocfg --help -LUN crypto_target_container_name LUN_Num initiator_PWWN cryptocfg --enable -LUN crypto_target_container_name LUN_Num initiator_PWWN cryptocfg -all -cfg | -stat Fabric OS Command Reference 131 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 160
configuration of "virtual devices" that is created for each target port hosted on a Brocade Encryption Switch or FS8-18 blade. The container holds the configuration set supports the following tasks: 1. Configure and configuration. Refer to the Appendix of the Fabric OS Encryption Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 161
encryption group, or specify a crypto_target_container_name for information on a specified CTC. The display includes the following information: • Encryption group name • Number of containers • For each container: - Container name: user-defined name Fabric OS Command Reference 133 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 162
Encrypt existing data: enabled or disabled • Rekey: enabled or disabled • LUN state: See the appendix in the Admin Guide. • Encryption algorithm • Key ID state: Re-key • Key ID • Key creation time • Key life (in days) • Rekey status • Key expiration time • Rekey session number • Percentage complete - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 163
to the Admin Guide, Appendix - Encryption algorithm: AES256 -XTS (disk), AES256-CCM (tape), or none - Compression algorithm - Key ID state - Key ID When used with -cfg the --show -LUN command displays LUN configuration information: • EE node: node WWN • EE slot: EE slot number Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 164
- Tape policy configuration details: - Tape pool or tape - Encryption or Cleartext - Key life span in days - Encryption Algorithm - Compression Algorithm • Number of Tape sessions in progress • For each Tape session the display includes: - Tape Session Number 136 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 165
all re-key sessions in progress for a specific Crypto LUN/initiator pair of a specific CryptoTarget container. The display includes the following information: • LUN number • LUN Serial Number (SN) • CryptoTarget container Name: user-defined name Fabric OS Command Reference 137 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 166
number - Percent completion - Re-Key state. Displays one of the following: • Re-Key Setup Number of tape sessions in progress • Container name: user-defined label • EE node name: node WWN • EE Slot Number • Target PWWN • Target NWWN • Target PID • VT PWWN • VT NWWN • VT PID • Host PWWN 138 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 167
is created. Upon commit of a CTC configuration, one virtual target (VT) is created, and for each initiator that has the access to the target port, one virtual initiator (VI) is created. These virtual devices are created by logging into the fabric and registering with the Name Server. Initiator - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 168
target and associated LUNs from the fabric. Before issuing this command, you must stop all traffic to the target port for which the CTC is container for a listing of valid CTC names. --failback -EE Performs a manual failback of all CTCs that were failed over earlier to another encryption engine - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 169
number of the new encryption engine. --move -container Moves the specified CTC from its currently configured part of the same encryption group for this operation to succeed, but they do not need to be part CTC to enable access for these initiators port WWN. Fabric OS Command Reference 141 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 170
multi-path LUNs exposed through multiple target ports and thus configured on multiple CTCs on different EEs in an HA cluster or DEK cluster, the same LUN policies must be configured. Refer to the Fabric OS Encryption Administrator's Guide for more information. The following LUN policy parameters - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 171
requires a NetApp DataFort-compatible license to be present on the encryption switch or the chassis that houses the encryption blade. -encrypt | -cleartext Enables or disables the LUN for encryption. By default, cleartext is enabled (no encryption). When the LUN policy is changed from encrypt to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 172
Fabric OS Encryption Administrator's Guide. numbers associated with the specified CTC. initiator_PWWN Specifies the initiator port WWN for the LUN to be removed. --enable -LUN Forces the LUN to become enabled for encryption from a disabled state. This command must be executed on the local switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 173
). Use of this format requires a NetApp DataFort-compatible license on the encryption switch or on the chassis that houses the encryption blade. -encrypt | -cleartext Enables encryption or cleartext (no encryption). By default, cleartext is enabled. Fabric OS Command Reference 145 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 174
CTC to which this LUN belongs. LUN_Num Specifies the number of the LUN to be re-keyed. Use --show -container for a list of LUN numbers associated with the specified CTC. initiator_PWWN Specifies the port WWN of the initiator for the specified LUN. 146 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 175
. The following operands are supported: -all -cfg Displays the configuration for all containers in the configuration or runtime status information for a single tape pool specified either by a tape pool label or a number. These operands must be used with either the -stat or the -cfg option. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 176
configuration or runtime status information for a specified CTC. This command is valid on all nodes. The following operands are supported: crypto_target_container_name Specifies the CTC for which to display the Crypto LUN information. LUN_Num Specifies the number 148 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 177
page 159 For additional examples and configuration procedures, refer to the Fabric OS Encryption Administrator's Guide. A. Node configuration To initialize a node and generate certificates (output shows what is generated and where it is stored): SecurityAdmin:switch>cryptocfg --initnode This will - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 178
or chassis: SecurityAdmin:switch>cryptocfg -regEE Operation succeeded. To enable an encryption engine: SecurityAdmin:switch> cryptocfg --enableEE Operation an external host: SecurityAdmin:switch>cryptocfg --export -scp -KACcert 192.168.38.245 mylogin kac_lkm_cert.pem Password: Operation succeeded. To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 179
Encryption group configuration To create an encryption group "brocade": SecurityAdmin:switch> cryptocfg switch>cryptocfg --eject -membernode 10:00:00:05:1e:53:b8:45 Eject node status: Operation Succeeded. To leave the encryption group: SecurityAdmin:switch>cryptocfg --leave_encryption_group Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 180
encryption group configuration: SecurityAdmin:switch>cryptocfg --show -groupcfg Encryption Group Name: brocade Failback mode: Manual Heartbeat misses: IP address Role 10:00:00:05:1e:41:9a:7e 10.32.244.71 GroupLeader(current node) 10:00:00:05:1e:39:14:00 10.32.244.60 MemberNode 152 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 181
: DEF_NODE_STATE_DISCOVERED Role: MemberNode IP Address: 10.32.244.60 Certificate: enc1_cpcert.pem Current Master Key State: Not configured Current Master KeyID: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00 Alternate Master Key State:Not configured Fabric OS Command Reference 153 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 182
:00:00:00 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00 C. Group-wide policy configuration To set the failback mode to manual failback: SecurityAdmin:switch> cryptocfg --set -failbackmode manual Set failback policy status: Operation Succeeded. To set the heartbeat miss value to 3: SecurityAdmin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 183
1 EE entry Status: Defined WWN Slot Number 10:00:00:05:1e:39:53:67 0 Status Online To initiate a manual failback of an encryption engine: SecurityAdmin:switch> cryptocfg --failback -EE 10:00:00:05:1e:39:53:67 0 22:00:00:04:cf:6e:57:62 Operation Succeeded Fabric OS Command Reference 155 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 184
includes initiator and target. a. Determine the device configuration. FabricAdmin:switch>nsshow { Type Pid COS PortName NodeName TTL(sec) N 010600; 2,3;10:00:00:00:c9:2b:c9:3a;20:00:00:00:c9:2b:c9:3a; na NodeSymb: [35] "Emulex LP9002 FV3.82A1 DV5-4.81A4 " Fabric Port Name: 20:06:00:05:1e:41 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 185
Number of host(s): 1 Configuration enabled. FabricAdmin:switch>cryptocfg --add -LUN my_disk_tgt 0 10:00:00:00:c9:2b:c9:3a 20:00:00:00:c9:2b:c9:3a -lunstate cleartext -encrypt Operation Succeeded 7. Commit the device configuration. FabricAdmin:switch Fabric OS Command Reference 157 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 186
enabled Encryption algorithm: AES256-XTS Key ID state: Read write Key ID: 3a:21:6a:bd:f2:37:d7:ea:6b:73:f6:19:72:89:c6:4f Key creation time: Sun Jun 1 20:21:32 2008 Operation Succeeded 9. Display Crypto LUN configuration. FabricAdmin:switch :1d Number of host(s): 1 Configuration status: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 187
:53:68:28 20:0a:00:05:1e:53:8a:24 20:0b:00:05:1e:53:8a:24 1 To display all configured tape pools: FabricAdmin:switch> cryptocfg --show -tapepool -all Tape pool label: Key life: Encryption mode: Encryption format: Configuration status: tpool.00001 0 (minute) encrypt native committed(2) Tape pool - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 188
:53:74:fd LUN number: 0x0 LUN type: disk LUN status: 0 Encryption mode: encrypt Encryption format: native Encrypt existing data: enabled Rekey: enabled Key ID: not available Key life: 3000 (minute) Rekey status: 0 Operation Succeeded 160 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 189
36587 Number of uncompressed bytes: 2455059456 Number of compressed bytes: 1138031028 LUN number: 0x1 Tape session number: 1 Number of uncompressed blocks: 0 Number of compressed blocks: 0 Number of uncompressed bytes: 0 Number of compressed bytes: 0 Operation succeeded. None Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 190
command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, display sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 191
into account daylight saving time and the time zone setup of the switch. Each switch takes care of converting the GMT time distributed fabric-wide to its local time. Refer to tsTimeZone for more information on time zone support. If the switch is operating in FICON Management Server mode (fmsmode - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 192
To display the current date and time and then modify it: switch:admin> date Fri Jan 29 17:01:48 UTC 2007 switch:admin> date "0227123007" Thu Feb 27 12:30:00 UTC 2007 errShow, ficonCupSet, ficonCupShow, portLogShow, tsClockServer, tsTimeZone, upTime 164 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 193
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference 165 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 194
effect, allowing access to all devices. When a user-specified zone configuration is enabled, it overrides the Default Zone access mode. Notes This command must be run from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 195
--noaccess primaryfcs:admin> cfgsave primaryfcs:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction primaryfcs:admin> cfgactvshow Effective configuration: No Effective configuration: (No Access) none Fabric OS Command Reference 167 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 196
clear. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none 168 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 197
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To disable the POST: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 198
place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable the POST: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost 170 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 199
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display diagnostic command information: switch:admin> diaghelp bpportloopbacktest bpturboramtest burninerrclear burninerrshow burninstatus Functional test of port via blade - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 200
is displayed. Examples To enable and then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost, diagEnablePost 172 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 201
operand to display the current mode setting. If no operand is specified, the current value is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none Fabric OS Command Reference 173 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 202
configuration variables used by the specified script and enters an interactive session. Using the full parameters, variables can be updated non-interactively. In interactive mode, the current value, default Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 203
in -use_bports displays; otherwise, the user ports specified in -uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25:24 2002 Slot: 1 UPORTS Port BPort Diag Active Speed ...... 0 15 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 204
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg 176 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 205
Device Connection Control Policy PWD Password Database and Password Configuration Policy AUTH E_Port and F_Port Authentication Policy FCS Fabric Configuration Server Policy IPFILTER IP-Filter Policy Each supported database has a switch-local configuration parameter that controls whether the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 206
Policy to domains 3 and 5 in the fabric: switch:admin> distribute -p "SCC;DCC" -d "3;5" To distribute the Switch Connection Control Policy, FCS Policy, and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "SCC;FCS;PWD" -d "*" Wildcard - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 207
fabric change occurs. Refer to dlsSet for a full description of load sharing. This command should be used only if devices connected to the fabric option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See Also aptPolicy, dlsSet, dlsShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 208
2 dlsSet dlsSet Enables the dynamic load sharing (DLS) option. Synopsis dlsset Description Use this command to turn on DLS when a fabric change occurs. Routing is based on the incoming port and the destination domain. This means that all traffic coming in from a port (either from an E_Port or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 209
. Refer to dlsSet for a description of load sharing. Notes DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 210
1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To set the DNS parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 211
supported on this platform" message. Note The execution of this command is subject to Virtual Fabric switch (indicates the physical position of the switch in the enclosure). connid The serial number of the switch used by the enclosure manager (not to be confused with the Factory Serial Number - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 212
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To clear the error log messages: switch:admin> errclear See Also errDump, errShow 184 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 213
and the end delimiters (including the colon) so that they are not displayed. If no arguments are supplied to the command, it instead displays the existing errDelimiterSet configuration. These delimiters are stored persistently. Note The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 214
/08/25-10:10:41, [SEC-1203], 9036, CHASSIS, INFO, Spir_67, Login information : Login successful via TELNET/SSH/RSH. IP Addr: 10.106.7.62 2008/08/25-10:13:41, [ZONE-1022], 9037, CHASSIS, INFO, Spir_67, The effective configuration has changed to meh. 186 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 215
:35:04, [FABR-1001], 9041, CHASSIS, WARNING, Spir_67, port 0, incompatible Long distance mode. 2008/08/25-11:39:35, [LOG-1000], 9043, CHASSIS, INFO, Spir_67, Previous message repeated 1 time(s) [output truncated] errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference 187 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 216
sensitive. Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING See Also To set the filter severity level for the console: switch:admin> errfilterset -d console -v warning errDump, errShow 188 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 217
modules: switch:user> errmoduleshow Module IDs: 1 KT 2 UT 5 LOG 6 CDR 9 PIXE 10 EGR 13 PS 14 RTE 17 BLDE 18 BLM 21 CFLD 22 CFMN (output truncated) 3 TRCE 7 BLPU 11 BL 15 AS 19 BPRT 23 CHPS 4 KTRC 8 PISP 12 PIC 16 AUTH 20 CER 24 CONF See Also errDump, errShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 218
, INFO, Spir_67, Login information : Login successful via TELNET/SSH/RSH. IP Addr: 10.106.7.62 [Type to continue, Q to stop: 2008/08/25-10:13:41, [ZONE-1022], 9037, CHASSIS, INFO, Spir_67, The effective configuration has changed to meh. 190 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 219
Q to stop: 2008/08/25-11:35:04, [FABR-1001], 9041, CHASSIS, WARNING, Spir_67, port 0, incompatible Long distance mode. [Type to continue, Q to stop: 2008/08/25-11:39 CR> to continue, Q to stop: q errDelimiterSet, errDump, errFilterSet Fabric OS Command Reference 191 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 220
; the serial port returns to the login: prompt. The exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout 192 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 221
to display the state of a port, relative to the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator: EMT Sent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 222
E_Port isolation nbrWWN Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid Link reset timer identifier and current state. red_ports All E_Ports that are connected to the same neighboring switch Note The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 223
Examples See Also To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: State: List: List Count: Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 62 P3 0x10068418 0 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 224
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 225
fabric log. By default, the fabric log is enabled. -e | --enable Enables the fabric log. -r size | --resize size Changes the maximum number of log entries. The specified size has to be at least 2 and a power of 2; otherwise, the command fails. Examples To display the fabric log: switch 24 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 226
will clear the logs. Are your sure you want to do the resize [y/n]? y To display the cleared fabric log after the size was changed: See Also switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow 198 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 227
to set priorities for principal switch selection. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a preference for a switch requesting to be the principal switch in a fabric, but they do not provide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 228
0 Principal Selection Mode disabled To enable the mode setting: switch:admin> fabricprincipal 1 Principal Selection Mode enabled To enable the mode setting and force fabric rebuild: switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) See Also fabricShow 200 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 229
, if present in the fabric. Examples The following example illustrates a fabric of four switches. "sw180" is the Principal switch. Three of the switches are configured to run IP over Fibre Channel. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 64: fffc40 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 230
:91 192.168.64.60 192.168.65.60 "sw60" The Fabric has 2 switches. To show additional details of the FC Router, if present: switch:admin> fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 231
Use this command to display the statistics for the fabric. The following information is displayed: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations as a result of any of the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 232
2 fabStatsShow Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow 204 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 233
fabric switch state structure information. This command is strictly for debugging; it is not intended as a user command. Note The execution of this command is subject to Virtual Fabric STATE Principal Domain: 2 Upstream Port: 64 Principal Wwn: 10:00:00:60:69:80:06:ce Principal Priority: 0x2 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 234
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: unit Specifies the number of the fan unit to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 235
"Command Availability" for details. Operands This command has the following operand: unit Specify the fan unit number to enable. Examples To enable a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See Also fanDisable, fanShow Fabric OS Command Reference 207 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 236
. The output from this command varies depending on switch type and number of fans present. Note This command is not available on non-bladed systems except for the Brocade 4100, 4900, and 5300. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 237
OS commands" and Appendix A, "Command Availability" for details. Operands Examples none To reboot the Control Processor without executing power-on self test (POST) on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference 209 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 238
be enabled on the blade. The blade comes up with GbE ports internally disabled. A maximum of four user ports per port group (0-7 or 8-15) may be configured as FC Fastwrite. This amounts to a maximum of eight FC Fastwrite ports per blade. The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 239
-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portCfg Fabric OS Command Reference 211 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 240
MBIST and LBIST Specifies the GbE port to test. By default, all GbE ports in the specified slotnumber are used. Valid number values include: 0 GbE port 0 1 GbE port 1 2 All GbE ports Examples To run all tests on slot 7 and GbE port 1: switch:admin> fcipchiptest --slot 7 -unit 1 -testtype - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 241
When a failure is detected, the test might report one or more of the following error messages: CHIP_TEST_ERR CHIP_TEST_CHIP_INIT_ERR CHIP_TEST_IMAGE_VER_ERR CHIP_TEST_TIMEOUT_ERR CHIP_TEST_HEARBEAT_ERR CHIP_TEST_INVALID_RESULT See Also fcipPathTest Fabric OS Command Reference 213 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 242
. Synopsis fciphelp Description Use this command to display a short description of Fibre Channel over IP (FCIP) commands. FCIP commands require an FCIP license. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 243
test progresses until the specified number of frames are transmitted on each port. The default value is 100. -length data_length Specifies the data length of the frames used in the test. The default is 1,024; the maximum is 2,112 FC frames and 8,196 data packets. Fabric OS Command Reference 215 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 244
to select or to bypass data compression for the test. By default, data compression is used. This setting is applicable only to Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 245
which is used for any LUN query from this switch. Examples To display the LUN information: switch:user> fclunquery Target Index: 1 Target Node WWN: 50:05:07:65:05:03:f9:39 Target Port WWN: 50:05:07:65:05:83:f9:39 Target Pid: 144e8 Number of LUNs returned by query: 1 LUN ID: 0x00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 246
. The ELS Echo request elicits an ELS Echo response from a port identifier in the fabric and is useful for validating link connectivity. The source and destination port identifiers can be specified as a 24-bit Fibre Channel port identifier, a port World Wide Name, or a node World Wide Name. The two - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 247
for diagnosing data-dependent problems in the fabric link. The pattern bytes are specified as hexadecimal characters. For example, --pattern ff fills the request frame with instances of the number does not respond to the request: switch:admin> fcping 0x020800 22:00:00: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 248
this example, the destination is a switch WWN): switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 6: fffc06 10:00:00 switch:admin> nsshow { Type Pid COS PortName NodeName TTL(sec) N 370500; 3;20:07:00:05:1e:35:10:7f;10:00:00:05:1e:35:10:7f; na Fabric Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 249
fcPing 2 See Also switch:admin> fcping 20:00:00:00:c9:3f:7c:b8 Destination: 20:00:00:00:c9:3f:7c:b8 Pinging 20: bytes time:880 usec 5 frames sent, 5 frames received, 0 frames rejected, 0 frames timeout Round-trip min/avg/max = 713/774/880 usec ping Fabric OS Command Reference 221 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 250
information log. Synopsis fcplogclear Description Use this command to clear the debug information logged by the Fibre Channel Protocol daemon (FCPD). Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 251
command). Synopsis fcplogdisable Description Use this command to disable the logging of debug information by the Fibre Channel Protocol daemon (FCPD). Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 252
(debug command). Synopsis fcplogenable Description Use this command to enable Fibre Channel Protocol daemon (FCPD) logging. Debug information logging is enabled by default. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 253
Description Use this command to display the debug information logged at various stages during the Fibre Channel Protocol daemon (FCPD) device probing. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 254
Use this command to display the Fibre Channel Protocol daemon (FCPD) device probing information for the devices attached to the specified F_Port or FL_Port. This information includes the number of successful logins and SCSI INQUIRY commands sent over this port and a list of the attached devices - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 255
enable the following two configuration parameters: • Disable Device Probing = Enabled 1 • Disable RLS Probing = Enabled 1 Device probing and RLS probing are disabled by default. Use the configure command to enable these parameters. Note The execution of this command is subject to Virtual Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 256
or to display the current configuration. If no operands are specified, this command displays the usage. By default, frame forward option is enabled. Use the --show option to display the current settings on the switch. Note The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 257
To display the new configuration: switch:admin> fcrbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 SEE ALSO bcastshow, portRouteShow fcrBcastConfig 2 Fabric OS Command Reference 229 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 258
Fabric OS commands" and Appendix A, "Command Availability" for details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 259
fcrChipTest 2 Examples To run all tests on slot 7 and FC Router FPGA 1: switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest Pass BIST_TIMEOUT BIST_FAIL fcrPathTest, portLoopbackTest Fabric OS Command Reference 231 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 260
interactively prompts for the following parameter: Backbone Fabric ID A fabric ID uniquely identifies a fabric in FC Router configurations. The backbone fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 261
includes: EX_Port The port number for the EX_Port. An asterisk (*) at the end of the line indicates that the EX_Port is a Remote Router Port. FID The fabric ID of the EX_Port. Neighbor Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch attached to the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 262
FID Neighbor Switch Info (enet IP, WWN, name) 16 80 10.32.66.180 10:00:00:05:1e:34:e8:46 "b4100_7x_1" 180::10:32:66:180 27 80 10.32.69.180 10:00:00:05:1e:37:12:e0 "Sprint_180" See Also fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow 234 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 263
be disabled when you configure enforce tags. Speed tags can be configured while the switch is online. • You must change the LSAN name in the edge fabric or the backbone fabric and propagate the LSAN to the FCR. Note that enforce tags are not supported in the backbone fabric. • The speed tags must - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 264
the specified tag from the LSAN tag configuration. Displays command usage. Accepts only the LSANs from the edge fabric that matches the specified tag string switch:admin> switchdisable switch:admin> fcrlsan --add -enforce brocade LSAN tag set successfully To add a speed tag named "mcdt": switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 265
maximum LSAN count for all the FCR switches in the same backbone that support this feature. Verify the configured maximum limit against the LSANs configured using the fcrResourceShow command. Notes The default LSAN count maximum of 3000 is the Fabric OS v5.2 default. It allows v5.2 to run on the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 266
practice is, therefore, to enter the same information for all the FCR switches in the backbone that support this command. This command is also used to specify FC Router pairs that can talk to each other. All edge fabrics connected to a defined pair of FCRs are allowed to import devices each other - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 267
fcr wwn wwn Removes the entry of the pair of FIDS. If no longer specified, the edge fabric assumes the default behavior. --apply -lsan | -fcr | -all Applies the information from the cache to the LSAN Zone matrix from the import/export setup. Fabric OS Command Reference 239 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 268
19 To view the LSAN Zone static and default/dynamic binding in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10: switch:admin > fcrlsanmatrix --fabricview -lsan LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 4 5 4 7 10 19 Default LSAN Matrix: 1 2 8 To display all proxy - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 269
:29:31 78 10:32:16:90:29:dd:d0:07 78 10:32:16:91:24:dd:d0:05 78 10:32:16:91:25:dd:d0:03 82 10:00:00 and the default/dynamic fabric binding in the backbone: switch:admin > fcrlsanmatrix --fabricview -lsan LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 52 78 52 82 78 82 Default LSAN - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 270
on all the FCR switches in the backbone. • In a dual backbone configuration, use fcrlsanmatrix --fabricview on the FCR switches to confirm that the shared edge fabric FIDs have the same access in both backbones. Refer to the Fabric OS Message Reference manual for further diagnostic information - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 271
number of frames transmitted is not equal to the number of frames received. 8. Repeat steps 2 through 7 for all ports present until one of the following conditions is met: a. The number 0xbc, 0xbc, 0x23, 0x47, ... RANDOM0x25, 0x7f, 0x6e, 0x9a, ... Fabric OS Command Reference 243 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 272
is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. The switch must be offline for this test to run. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 273
SFP or indicate deeper problems in the main board or ASIC. Check for a faulty SFP. Replace the SFP if necessary. The specified port failed to transmit frames. This usually indicates an ASIC failure. Replace the blade or the switch. See Also fcrChipTest, portLoopbackTest Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 274
physical devices include physical devices that are configured to be exported from fabrics attached to this FC Router's EX_Ports. The physical devices are listed by fabric. The -f and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. "No device found" is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 275
fcrPhyDevShow 2 Examples To display the physical devices relevant to this FC Router: fcr:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 276
. If the configuration is altered, then care must be taken to ensure consistency across all FC Routers attached to the same edge fabric. If no operand is specified, the command displays the following information: importedFID The imported fabric ID of the proxy device. devWWN The port World Wide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 277
not exist in any proxy device slot." is displayed if the WWN does not exist in any slot for the specified edge fabric. Examples To display the persistent proxy device configuration: switch:admin> fcrproxyconfig Imported FID 002 002 002 002 003 Device WWN 50:05:07:65:05:84:08:d7 50:05 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 278
device appears to the fabric as a real Fibre Channel device. It has a name server entry and is assigned a valid port ID. Proxy device information is available only for proxy devices that are presented by FC Routers on the same backbone fabric as this FC Router. The default output displays only - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 279
that are relevant to this FC Router. Displays proxy devices with the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 280
a translate domain slot. A slot is the port number and AL_PA combination. The slot-to-device WWN association is persistently stored. Phantom Node WWNs The maximum versus the currently allocated phantom switch node WWNs. The phantom switch requires node WWNs for fabric-shortest-path-first (FSPF) and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 281
fcrResourceShow 2 Notes Only configured EX/VEX_Ports are displayed The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 282
link costs for all ports on the switch. Notes Before setting the cost, ensure that admin is enabled for the EX_Port/VEX_Port with portCfgEXPort or portCfgVEXPort. The cost can be set only on a disabled port. The bandwidth of an inter-fabric link (IFL) is unrelated to its default cost. In other - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 283
fcrrouterportcost 7/10 Port Cost 7/10 10000 To set the default cost on the EX_port: switch:admin> fcrrouterportcost 7/10 0 switch:admin> fcrrouterportcost 7/10 Port Cost 7/10 1000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 284
EX_Port. NR_Port technology enables EX_Ports to exchange traffic across an intermediate fabric. NR_Ports are addressable entities on the backbone fabric and have port IDs relevant to the backbone fabric. Because cascaded backbone/intermediate fabrics are currently not supported, an NR_Port provides - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 285
translate domain ID is configured if no devices are imported or exported across the edge fabrics. Disabling the persistxd parameter prevents the translate domain from being created. Enabling the persistxd parameter from a disabled state re-enables the FCR default behavior. When executed without - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 286
display the translate domain configuration and the state of the persistxd parameter: switch:admin> fcrxlateconfig ImportedFid ExportedFid Domain 001 002 004 001 005 003 OwnerDid 000001 N/A XlateWWN N/A 50:00:51:e1:30:30:0f:05 Persist XD state: Enabled 258 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 287
:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To clear the preferred domain ID of the translate domain created in fabric 2, which represents remote fabric 3: switch:admin> fcrxlateconfig -r 2 3 xlate domain deleted To enable translate domain persistence: fcr:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 288
the fabric-wide consistency policy. Switches can be locally configured to allow or reject a security policy. Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC), Password (PWD), Fabric Configuration Server (FCS), Fabric Element Authentication (AUTH), and IP Filter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 289
of the form "SCC:S;DCC;FCS". To set the fabric-wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC), and Fabric Configuration Server (FCS). All members specified in a given policy - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 290
FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60:69:90:03:c7 HBAs: 10:00:00:00:c9:25:9b:96 Ports: 1 10:00:00:00:c9:25:9b:96 Total count of devices on the switch is 1 See Also fdmiShow 262 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 291
Supported Speed: 0x00000001 Port Speed: 0x00000001 Frame Size: 0x00000800 HBA attributes: Node Name: 20:00:00:00:c9:25:9b:96 Manufacturer: Emulex Network Systems Serial Number: 0000c9259b96 Model: LP9000 Model Description: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 292
To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear the RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp, ficonShow 264 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 293
timeout value is rounded down to the closest value divisible by 10. For example, an MIHPTO timeout value of 86 defaults to 80. Examples To enable FMS mode for the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled Fabric OS Command Reference 265 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 294
bit in the mode register for the switch: switch:admin> ficoncupset modereg ASM 1 Active=Saved Mode bit is set to 1 See Also To set the MIHPTO value to 60 seconds: switch:admin> ficoncupset MIHPTO 60 MIHPTO has been changed to 60 seconds ficonCupShow 266 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 295
seconds. Examples To display the FMS mode for the switch: switch:user> ficoncupshow fmsmode fmsmode for the switch: Enabled To display the mode register for the switch: switch:user> ficoncupshow modereg POSC UAM ASM DCAM ACP HCP 1 0 1 1 1 0 Fabric OS Command Reference 267 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 296
2 ficonCupShow To display the ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also To display the MIHPTO value for the CUP: switch:user> ficoncupshow MIHPTO MIHPTO for the CUP: 60 seconds ficoncupset 268 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 297
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Clears contents of the specified FICON management database - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 298
domain ID. Fabric WWN Displays the fabric WWN. Flag Indicates if the node is valid, not valid, or not current. Flag values are as follows: 0x00 Indicates the node ID of the storage port for RNID switch for SwitchRNID is valid. 0x10 Indicates the node ID of the channel port is valid. 0x20 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 299
port state Listener PID Same as PID. Listener Port Type Same as Port Type. Listener Port WWN Displays the channel HBA port . Byte BB 0x0a Switch. Byte CC 0x00 Port number. It is dynamically support not specified. 0xa0 Reserved. 0xc0 Reserved. Fabric OS Command Reference 271 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 300
registered with the switch. 0xID CHIPID if channel port has registered with the switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Part Number Displays the switch chassis part number. PID Displays the 24-bit Fibre Channel port address in 0xDDAAPP format - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 301
channel or storage CU port World Wide Name associated with the device HBA. Sequence Number Displays the sequence number of the self-describing node. Serial Number Displays the switch serial number. Switch node WWN Displays the switch node World Wide Name. Switch Port fabric ILIR Specify fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 302
Number: 0000000169CA tag: 052e } } To display the local and remote LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20:2b:00:60:69:80:1e:4e Conditional 0x18 N 502e00 50:05:07:64:01:40 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 303
: switch:user> ficonshow ILIR { {FRU Failure [2]: Power Supply[2] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 304
modified through configDownload. FIPS is not supported on all platforms. For FIPS-compliant hardware, refer to the Fabric OS Administrator's Guide. In a Virtual Fabric environment, FIPS is treated as chassis-wide configuration and applies to all logical switches in the chassis. Chassis permissions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 305
in permit state. HTTP port number for the policy is in permit state. RPC port number for the policy is in permit state. SNMP is not in read only mode. Bootprom access is enabled. FIPS mode cannot be configured at this time Fabric OS Command Reference 277 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 306
2 fipsCfg To enable FIPS after prerequisites have been met: switch:admin> fipscfg --enable fips FIPS mode has been set to : Enabled Please reboot the system switch:admin> fipscfg --show FIPS mode is : Enabled See Also none 278 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 307
switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To commit a new version of the firmware: switch: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 308
BP firmware is downloaded to the BP processors if there is a mismatch between the BP and CP firmware. By default, firmwareDownload performs a full install, auto reboot, and auto commit. These modes are selectable only in single CP (-s) mode, in which case auto reboot is OFF by default. 280 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 309
single-CP mode. This mode supports selectively enabling or disabling a full install, auto reboot, and auto commit on bladed and non-bladed systems. On enterprise-class platforms, this mode supports upgrading a single CP. When downloading the main Fabric OS firmware, this option disables auto - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 310
this option may cause traffic disruption for some switches in the fabric. Examples To download the firmware to an HA switch over a network: switch:admin> firmwaredownload 192.168.166.30,johndoe,/pub/dist/release.plist,12345 The following BP blades are installed in the system. Slot Name Versions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 311
) [FOS]:SAS Target Slots (all, or slot numbers) [all]: Server Name or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User Name: userfoo File Name: /home/userfoo/dist/release.plist Password: To download SAS firmware without version compatibility checking: Note that in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 312
reachable from the switch. • The user does not have permission on host. • The password is not specified correctly. • Indicated firmware does not exist on the host, or is not in the right format, or is corrupted. • The FTP or SSH service is not running on host. • The platform is not supported by the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 313
is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2007 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 314
command has completed successfully. Use firmwareshow to verify the firmware versions. To display the status of a firmware download on a chassis: switch:admin> firmwaredownloadstatus [1]: Mon Dec 19 18:40:19 2007 Slot 6 (CP1, active): Firmware is being downloaded to standby CP. This step may take up - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 315
successfully. [11]: Mon Dec 19 18:55:39 2007 Slot 5 (CP0, active): Firmware has been downloaded successfully on Standby CP. [12]: Mon Dec 19 18:55:46 2007 Slot 5 to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 316
on every switch as a part of the Fabric OS installation. The presence of a firmware key does not imply that the firmware signature is checked during firmwareDownload. Signed Firmware Download must be enabled before the public key can be used for signature validation. Use the configure command to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 317
switch as a part of the Fabric OS installation. The presence of a firmware key does not imply that the firmware signature is checked during firmwareDownload. Signed Firmware Download must be enabled before the public key can be used for signature Use the configure command to enable Signed Firmware - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 318
updated. To update the public key using the interactive method: switch:admin> firmwarekeyupdate Server Name or IP Address: 192.168.21.34 User Name: johndoe File Name: /pub/dist/pubkey.pem Network Protocol(1-auto-select, 2-FTP, 3-SCP) [1]: Password: Updating the public key, please wait... Public key - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 319
), the downloaded firmware becomes active. If you then do not want to commit the firmware and want to restore the former firmware, run Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To restore the former active firmware image: switch:admin> - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 320
in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7: switch:admin> firmwareshow Slot Name Appl Primary/Secondary - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 321
FC Routing service is already enabled. iSCSI Enables the iSCSI service on the switch. By default, iSCSI is disabled. iSNSC Enables the iSNSC service on the switch. By default, iSNSC is disabled. vf Enables Virtual Fabrics. By default, Virtual Fabrics are disabled. Before enabling the Virtual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 322
Virtual Fabric: enabled enabled disabled enabled To disable the FC Routing service: switch:admin> fosconfig --disable fcr FC Routing service is disabled To enable the FC Routing service: switch:admin> fosconfig --enable fcr FC Routing service is enabled To enable the iSCSI service: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 323
fosConfig 2 To enable Virtual Fabrics: switch:admin> fosconfig --enable vf WARNING: This is a disruptive operation that requires a reboot to take effect. All EX ports will be disabled upon reboot. Would you like to continue [Y/N]y To disable Virtual Fabrics: switch:admin> fosconfig --disable vf - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 324
, or CP failover, please follow the recovery procedure in Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now. If this session lost for any reason - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 325
FSPF protocol. Domain number of local switch. State of the local switch. TRUE if the domain of the local switch is currently confirmed. Bit map of all the ISL. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 326
2 fspfShow Examples To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 131 switchOnline = TRUE lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 298 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 327
has the following operand: mode Specify 1 to enable the alarms, 0 to disable the alarms. If no operand is specified, the default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 328
Availability" for details. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 300 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 329
this command to initialize all classes under Fabric Watch. The command should only be used after installing a Fabric Watch license to start licensed Fabric Watch classes. Refer to fwConfigure for a list of classes. Notes This command requires a Fabric Watch license. The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 330
Fabric Watch configuration. This command should only be used after downloading a new Fabric Watch configuration file from a host. Notes This command requires a Fabric reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 331
modifies the Fabric Watch configuration. Synopsis fwconfigure fwconfigure --enable --port portNumber fwconfigure --disable --port portNumber Description Use this command to display and modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 332
QL Fabric logins SFP state changes Link loss (E_Port) Sync loss (E_Port) Signal loss (E_Port) Protocol error (E_Port) Invalid words (E_Port) Invalid CRCS E_Port) RX Performance (E_Port) TX Performance (E_Port) State Changes (E/VE_Port) Utilization (VE_Port) Packet Loss (VE_Port) Same as Port class - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 333
Fabric reconfigure Domain ID changes Segmentation changes Zone changes FabricQL Fabric logins SFP state changes Same as Port class Same as Port Fabric OS commands" and Appendix A, "Command Availability" for details. Not all platforms support fans or power supplies. If you attempt to configure - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 334
the following optional operands: --enable --port portNumber Enables all thresholds associated with a certain port. --disable --port portNumber Disables all thresholds associated with a certain port. Examples To configure thresholds in Fabric OS mode: switch:admin> fwconfigure 1 : Environment class - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 335
21 C In_Range 2 envTemp002 enabled 24 C inBetween Sat Oct 7 10:01:53 2006 21 C In_Range 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 336
2 fwFruCfg fwFruCfg Displays or modifies FRU state alert configuration. Synopsis fwfrucfg [--show] Description Use this command to configure field-replaceable unit (FRU) states and actions. Based on these configuration settings, Fabric Watch generates action when a FRU state changes. To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 337
Fabric Watch Configure FRU state and notification Print Fabric Watch help info Configure Fabric Watch Email Alert Create a report with detailed port information Show availability monitor information Set port persistence time Set boundary & alarm level to custom Set boundary & alarm level to default - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 338
Alert 3 : Enable Email Alert 4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Relay Host IP Configuration 7 : Quit Select an item => : (1..7) [7]1 Config Show Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 339
Email Alert 3 : Enable Email Alert 4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Relay Host IP Configuration 7 : Quit Select an item => : (1..7) [7]5 Mail Config Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 340
factors also are listed. Notes This command requires a Fabric Watch license. Port errors are not supported for virtual ports and SFP errors are not applicable for virtual ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 341
002:53 005 U OFFLINE 080:24 006 U OFFLINE 080:24 007 U OFFLINE 080:24 To retrieve a port detailed report for a switch configured with an IPv4 address: switch:user> fwportdetailshow Port Detail Report Switch Name: switch IP address: 10.202.78.24 Port Exception report [by All] Report - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 342
See Also To retrieve a port detailed report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 192.168.163.237 Port Exception report [by Healthy] Report time: 05/21/2007 11:22:58 PM --------Port-Errors SFP-Errors---- Port# Type State Dur(H:M) LFA - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 343
" and Appendix A, "Command Availability" for details. This command requires a Fabric Watch license. Operands none Examples To generate a SAM report on an eighty-port switch: switch:user> fwsamshow Total Total Down Total Port Type Up Time Down Time Occurrence Offline Time (Percent) (Percent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 344
0 0 0 100 37 U 0 0 0 100 38 U 0 0 0 100 39 U 0 0 0 100 40 T 99 0 0 0 41 T 99 0 0 0 42 T 100 0 0 0 43 T 99 0 0 100 77 U 0 0 0 100 78 U 0 0 0 100 79 U 0 0 0 100 See Also portShow, switchShow 316 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 345
Specifies the time, in seconds, during which a port must be persistently in a marginal state before being recognized as such. Examples To set the port persistence time to 18 seconds: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference 317 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 346
. Fabric Watch uses two types of settings: factory default settings and user-defined custom settings. • Factory default settings are automatically enabled. These settings vary depending on hardware platform, and cannot be modified. • For some settings, you can create custom threshold configurations - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 347
a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to Custom Unit Time base Low High BufSize Default C 0 60 base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 348
2 fwSetToCustom 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToDefault, fwConfigure, fwHelp, fwShow 320 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 349
. Fabric Watch uses two types of settings: factory default settings and user-defined custom settings. • Factory default settings are automatically enabled. These settings vary depending on hardware platform and cannot be modified. • For some settings, you can create custom threshold configurations - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 350
4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 4 Index ThresholdName 1 envTemp001 4 envTemp004 5 envTemp005 6 envTemp006 BehaviorType Triggered Triggered Triggered Triggered BehaviorInt 1 1 1 1 Threshold boundary level is set at : Default Unit Time base Low - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 351
10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToCustom, fwConfigure, fwHelp, fwShow fwSetToDefault 2 Fabric OS Command Reference 323 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 352
, refer to the help page for fwConfigure or consult the Fabric Watch Administrator's Guide. In Access Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms. TABLE 15 Access Gateway mode classes Class Environmental - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 353
Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show port persistence time 4 : Quit Select an item => : (1..4) [3] 2 Enter Threshold Name : [] envFan001 Env Temperature 1: Monitored - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 354
time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s To display ports that have all thresholds disabled: switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit, fwConfigReload, fwConfigure, fwSet 326 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 355
commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none Fabric OS Command Reference 327 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 356
Description Use this command to disable the High Availability (HA) feature on a switch. If the HA feature is already disabled, this command does nothing. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 357
CP would reboot, and the failover would be disruptive. • IP and Fibre Channel addresses configured for the switch. • Additional internal HA state information, subject to change. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 358
CP (Slot 5, CP0): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized SWITCH Ethernet IP Address: 10.32.227.64 Ethernet Subnetmask: 255.255.240.0 Fibre Channel IP Address: 220.220.220.64 Fibre Channel Subnetmask: 255.255.240.0 CP0 Ethernet IP Address: 10.32.227.66 Ethernet Subnetmask - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 359
that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable the High Availability feature: switch:admin> haenable HA is enabled See Also haDisable Fabric OS Command Reference 331 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 360
(HA) synchronization is enabled and the CPs are in sync, the port traffic light does not flash during the failover, even while traffic is continuing to flow. This command is supported only on dual-CP systems. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 361
number and CP ID), warm or cold, recovering or recovered. • Remote CP state (slot number and CP ID). • High Availability (enabled problem a configuration file supported on non-bladed systems. Slot numbers Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 362
To display CP status on a Brocade DCX with a healthy standby CP: switch:admin> hashow Local CP (Slot 7, CP1) : Active Remote CP (Slot 6, CP0) : Standby, Healthy HA Enabled, Heartbeat Up, HA State Synchronized See Also haDisable, haEnable, haFailover 334 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 363
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 364
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart 336 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 365
commands for which help is available. At the end of the list are some additional commands which to the current user; command availability may vary depending on: • Login user role • License key switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 366
(WWN) cards. The type of FRU supported depends on the hardware platform. Each history record switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyShow 338 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 367
buffer, which records the insertion and removal of FRUs on a switch or chassis. This command supports two modes of handling new log entries once the history buffer is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 368
of FRU supported depends on Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the history log of FRUs and removal events on a standalone switch: switch:admin> historyshow FAN Unit 3 Removed at Tue Aug 14 10:05:37 1970 Factory Part Number - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 369
Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyLastShow Fabric OS Command Reference 341 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 370
may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,5,0,6 javaplugin.homeURL = http://java.sun - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 371
process or about all processes running on the local switch. One line is displayed per process. Fields displayed or stopped Z a defunct ("zombie") process The effective user ID number of the process The process ID of the process The to Virtual Fabric or Admin Domain restrictions that may be in place. - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 372
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 373
usage. Examples To disable the ICL for ports 16-31: switch:user> iclcfg --disable 8/1 To enable the ICL for ports 16-31: switch:user> iclcfg --enable 8/1 To disable the ICL for ports 16-31 persistently: switch:user> iclcfg --persistentdisable 8/1 Fabric OS Command Reference 345 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 374
2 iclCfg See also To enable the ICL for ports 16-31 persistently: switch:user> iclcfg --persistentdnable 8/1 none 346 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 375
subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" supported. Examples To advertise all modes of operation, when not entering this command through the serial console port, follow this scenario for the ifModeSet command: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 376
[yes] y Committing configuration...done. To force the link for the eth0 interface from auto-negotiation to 10 Mbps half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps / Full Duplex (yes - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 377
-HD, link ok MAC Address: 00:60:69:D0:24:40 To display the link operating mode for the eth3 Ethernet interface (in this example, the management port is disconnected): switch:admin> ifmodeshow eth3 Link mode: no link MAC Address: 00:05:1E:40:62:30 Fabric OS Command Reference 349 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 378
2 ifModeShow To display the active interface: ras010:root> ifmodeshow bond0 Currently Active Slave: eth0 See Also ifModeSet 350 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 379
idbP Pointer to IDB. nghbP Pointer to neighbor data structure. ifNo Interface number. masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost of sending a frame over the interswitch link (ISL) connection to this - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 380
LSUs received from the neighbor switch. nLsaIn Number of LSAs received from the neighbor switch. attHloOut Number of attempted transmissions of Hello frames to the neighbor switch. nHloOut Number of Hello frames transmitted to the neighbor switch. 352 Fabric OS Command Reference 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 381
of LSUs to the neighbor switch. Number of LSUs transmitted to the neighbor switch. Number of attempted transmissions of LSAs to the neighbor switch. Number of LSAs transmitted to the neighbor switch. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 382
helloTo = 2000 rXmitTo = 5000 nCmdAcc = 7 nInvCmd = 0 nHloIn = 2 nInvHlo = 0 nLsuIn = 2 nLsaIn = 3 attHloOut = 2 nHloOut = 2 attLsuOut = 3 nLsuOut = 3 attLsaOut = 2 nLsaOut = 2 See Also nbrStateShow, portShow, switchShow 354 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 383
]] Use this command to enable or disable Brocade switch interoperability with McDATA switches within a Brocade fabric. Fabric OS v6.0.0 introduced a McDATA Enterprise OS (M-EOS)-compatible McDATA Open Fabric Mode (interopMode 3) on all platforms that support McDATA Fabric Mode (interopMode 2). Open - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 384
but there is no check that it is turned off. The configuration is reset. If you have a defined or effective configuration and default zoning is on, when you disable the switch and change to McDATA Open Fabric mode, you are informed that all configurations will be lost and that the system will reboot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 385
change to take effect. Do you want to continue? (yes, y, no, n): [no] y To enable McDATA Open Fabric mode on a disabled switch: switch:admin> interopmode 3 McDATA Open Fabric mode is enabled The switch effective configuration will be lost. The system will reboot to allow the change to take effect - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 386
the user-defined IOD delay settings to default values (-1). This command resets IOD delay values for a specified domain ID that was previously configured with the iodDelaySet command. The switch must be disabled before IOD delay can be reset. Notes The iodDelaySet command is deprecated in Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 387
values. Note The iodDelaySet command is deprecated in Fabric OS v6.2.0. The iodDelayReset command is retained for legacy reasons only. If you have configured IOD delay settings previously, you must reset the IOD settings to defaults before upgrading to v6.2.0. Use iodDelayShow to determine - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 388
in-order delivery enforcement on the local switch. IOD is disabled by default, and can only be disabled after it has been enabled with the iodSet command. This command disables the legacy IOD enforcement only. Disabling IOD allows faster re-routing after a fabric topology change, but it may cause - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 389
legacy IOD implementation. Lossless DLS is supported only in FICON environments, and the switch must be configured with a port-based policy. Refer to aptPolicy help for more information. Lossless DLS is not supported on extended interswitch links (ISLs). Fabric OS Command Reference 361 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 390
Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: --enable -lossLessDls Enables on the switch, this command enables both, IOD and the lossless DLS feature. --disable -lossLessDls Disables the previously enabled feature. - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 391
the in-order delivery (IOD) setting. Synopsis iodshow Description Use this command to display the IOD setting on the switch. By default, IOD is disabled. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 392
processor (AP). On platforms that support Logical Fabrics, this command configures the IPv4 Fibre Channel addresses for the logical fabric IPFC network interface. The IPFC (IP over Fibre Channel) protocol allows switches to send IP traffic over Fibre Channel rather than through Ethernet connections - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 393
and -noauto options to enable or disable stateless IPv6 auto configuration. • Use the -ls option with appropriate arguments to set or delete the IPv4 Fibre Channel address and prefix for the IPFC interface of a logical switch. In a Virtual Fabric environment, each logical fabric is represented by - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 394
is enabled, the host automatically performs configuration of IPv6 addresses and periodic non-disruptive re-configuration. By default, auto configuration is disabled. -ls FID Specifies the logical fabric ID for which to configure an IPFC network interface. The FID is a decimal number. A switch that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 395
address on an AP7600 with a hidden BP: switch:admin>ipaddrset -eth0 --add 10.12.34.123/24 To configure an IPv4 FC address for the IPFC interface associated with a logical switch with fabric ID 123: switch:admin>ipaddrset -ls 123 --add 11.1.2.4/24 IP address is being changed...Done. To verify the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 396
[255.255.255.0]: Committing configuration...Done. To enable DHCP on a standalone, non-AP platform: switch:admin> ipaddrset Ethernet IP Address [192.168.74.102]: Ethernet Subnetmask [255.255.255.0]: Gateway IP Address [192.168.74.1]: DHCP [Off]: on ipAddrShow 368 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 397
• Ethernet Subnet mask • Host Name • Gateway IP Address If the IPFC network interface is configured for logical switches: • IPFC address for Virtual Fabric ID For each CP: - Backplane IP address - IPv6 Auto configuration Enabled: Yes or No If enabled, the command displays: • All local IPv6 Addresses - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 398
the -slot option. Examples To display the IP addresses on a standalone switch: switch:admin> ipaddrshow SWITCH Ethernet IP Address: 192.168.163.238 Ethernet Subnetmask: 255.255.255.0 Gateway IP Address: 192.168.163.1 DHCP: Off IPv6 Autoconfiguration Enabled: No Local IPv6 Addresses: static 1080 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 399
205:1eff:fe39:e45a/64 preferred IPv6 Gateways: To display only the IP addresses for CP 1: switch:admin> ipaddrshow CP1 Ethernet IP Address: 10.33.60.87 Ethernet Subnetmask: 255.255.240.0 Host Name: cp1 Gateway IP Address: 10.33.48.1 See Also ipAddrSet Fabric OS Command Reference 371 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 400
and Appendix A, "Command Availability" for details. In a Virtual Fabric environment, IP Filter policies are treated as chassis-wide configurations and apply to all logical switches in the chassis. Chassis permissions are required to manage IP Filter policies. This command has the following operands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 401
policyname Adds a new rule to the specified IP filter policy. The change made to the specified IP filter policy is not saved to the persistent configuration until saved or activated. The following arguments are supported with the --addrule option: Fabric OS Command Reference 373 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 402
policies: switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any tcp - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 403
activated policy: switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 404
ipfilter --save ex2 switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 405
the algorithm selected. Refer to the Fabric OS Administrator's Guide for more information. The following IPsec configuration tasks can be performed with this command: • Enable or disable the IPSec policies. • Configure IP address for both IPv4 and IPv6 format. • Configure three types of policies and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 406
must be enabled before you can configure the policies and parameters. The following operand is optional: default Clears the existing policies (automatic key management and manual keyed entries) and resets the configuration databases to default values. --disable Disables IPsec on the switch. All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 407
. The main components of an IPsec policy are: IP packet filter/selector (IP address, protocol, and port information) and transform set. A subtype is required when configuring an IPsec policy. The subtype specifies the components to be configured. The following are required subtypes for the IPsec - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 408
, a local source IP address must also be defined. sa-proposal Defines the security associations (SA) proposal, including name, SAs to be included and lifetime of the proposal. The following operands are supported: -tag name Specifies a name for the SA proposal. This is a user-generated name. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 409
, data integrity and data source authentication of IP packets, and protection against replay attacks. Authentication number Specifies the security parameter index (SPI) for the SA. This is a user-defined index. Valid SPI numbers consist of numeric characters (0-9). This operand is optional. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 410
using digital signature standard. -dh number rsasig Authenticate using an RSA signature. Specifies the DH group number as one of the following: 1 Specifies DH group modp768. 2 Specifies DH group modp1024. 14 Specifies DH group modp2048. 382 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 411
keys expire after the specified number of bytes have been transmitted. -pfs on|off Enables or disables Perfect Forward Secrecy (PFS). PFS is disabled by default. When PFS is disabled, IKE specified all existing protocols are selected for protection. Fabric OS Command Reference 383 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 412
integrity and data source authentication of IP packets, and protection against replay attacks user-generated key based on the length of the key. Use the LINUX random key generator or any other comparable third party utility to generate the manual SA keys. Refer to the Fabric OS Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 413
the configuration database. Flushing any other policy parameters is not supported. --show type policy ips Displays current IPsec or IKE configuration. The configuration. A policy subtype must be specified when displaying the IPsec policy configuration. Valid subtypes include the following: Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 414
parameters: IKE version, IP address of the remote entity, IP address of the local Manually keyed SAs. 5. "IPsec display commands" - Verify your IPsec configurations. 6. "Using the help command" - Use the help command with arguments to get syntax information on specific parameters. 386 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 415
traffic flow using ipsecConfig --show manual-sa -a. Refer to the "IPsec display commands" section for an example. 10. Perform the equivalent steps on the remote peer to complete the IPsec configuration. Refer to your server administration guide for instructions. Example 2 Secure traffic between two - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 416
peer to complete the IPsec configuration. Refer to your server administration guide for instructions. Example 3 Secure traffic between two systems using AH with SHA1 and ESP protection with 3DES and configure IKE with pre-shared keys. The two systems are a switch, BROCADE300 (IP address 10.33.74.13 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 417
ESP01 bundle. switch:admin> ipsecconfig --add policy ips sa-proposal manual-sa -a. Refer to the "IPsec display commands" section for an example. 5. Perform the equivalent steps on the remote peer to complete the IPsec configuration. Refer to your server administration guide for instructions. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 418
switch:admin> ipsecconfig --show manual- switch:admin> ipsecconfig --show policy ips sa-proposal -a ipsec-esp-a-b SA(s) used:sa-esp-1 sa-ah-1 lifetime in seconds:infinite lifetime in bytes:infinite ipsec-esp-def SA(s) used:sa-esp-1 lifetime in seconds:infinite lifetime in bytes:infinite 390 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 419
selectors: switch:admin> ipsecconfig --show policy ips selector -a number ENCRYPTION ALGORITHM 3des_cbc, aes128_cbc, aes256_cbc, null_enc HASH ALGORITHM hmac_md5, hmac_sha1, aes_xcbc PRF ALGORITHM hmac_md5, hmac_sha1, aes_xcbc DH-GROUP modp768(1), modp1024(2), modp2048(14), modp8192(18) Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 420
Dec 2005). [4302] Kent, S., "IP Authentication Header", RFC4302 (Dec 2005). [4303] Kent, S., "IP Encapsulating Security Payload (ESP)", RFC4303 (Dec 2005). [4306] Kaufman, C., Ed., "The Internet Key Exchange (IKEv2) Protocol", RFC 4306 (Dec 2005). See Also none 392 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 421
iscsiCfg Synopsis Configures or displays iSCSI entities. iscsicfg create auth -u username -s CHAP_secret [-h] iscsicfg --modify auth -u username --enable ddset -n ddset_name [-h] iscsicfg --disable ddset [-n ddset_name] [-h] iscsicfg --show ddset [-n ddset_name] [-v] [-h] iscsicfg --show fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 422
-enabled switches and blades in the fabric. Changes do not take effect until a --commit all command is issued. Make all necessary configuration changes by the port WWN. --easycreate tgt -s [-h] Shows the Node and Port WWNs which is used for any easycreate operation from this switch. --create tgt - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 423
based on the login frame from the host. --addusername tgt -t target_name -u user_list [-h] Binds user user names defined in AUTH database from the specific target --clear tgt [-h] Clears the iSCSI target database from the fabric are not a part of the IQN format is supported. Multiple entities - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 424
. ddset_name is optional. fabric iSCSI-enabled switches and their operational states. The action is --show. --show fabric[-h] Displays the database iSNS client status of all iSCSI switches in the fabric. An asterisk (*) next to the switch ID denotes the local switch. initiator iSCSI Initiator - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 425
iscsiCfg 2 --commit all [-f] [-h] Commits the iSCSI configuration database to nonvolatile memory. Any modifications made to the database are not saved until an explicit --commit all is issued. If multiple switches in the fabric have uncommitted changes, this operation is rejected. The -f option - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 426
. To unbind user CHAP from a target: switch:admin> iscsicfg 80:00:43:80:a2 Number of LUN Maps: 5 FC WWN Virtual LUN(s) Physical LUN(s) 50:06:0e:80:00:43:80:a2 0 0x0000000000000000 50:06:0e:80:00:43:80:a2 1 0x0001000000000000 50:06:0e:80:00:43:80:a2 2 0x0002000000000000 50:06:0e:80:00:43:80 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 427
myddset -d mynewdd The operation completed successfully. To display the iSCSI-aware switches and their operational states (Displays switches that are capable of propagating iSCSI data base): switch:admin> iscsicfg --show fabric Switch ID Switch WWN Switch State iSNSC * 1 10:00:00:60:69:e4:20:1e - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 428
See Also To display the iSCSI initiators that attempted to log in: switch:admin> iscsicfg --show initiator Number of records found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 429
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: --slot slotnumber Specifies the slot number for which to run the diagnostics. The default is set to 0 and designed to operate on fixed-port-count products - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 430
. Manage/display iscsi switch configuration parameters. Create/Delete a new ip interface/route/arp entry on the GigE port Show configured ip interfaces/routes/arp entries on the GigE Port Display the number of sessions on each iSCSI port See Also switchShow 402 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 431
This command is supported only on the Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which to run the diagnostics. The default is set to 0 and designed to operate on fixed-port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 432
1 to enable. Enables or disables immediate data support; specify 0 to disable or 1 to enable. Specifies the first burst length value; values include 512, 1024, 2048, 4096, 8192, 16384, and 32768. --clearstats Clears port-level iSCSI statistics on the specified port. --default Resets the port to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 433
, which displays the initiator IP, TSID, and the number of connections in addition to the other port-level information. Specifies the slot number. This parameter only supports FC4-16IP blades in Brocade 48000 directors. Specifies the port number of a GbE port to be configured in the specified slot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 434
Session details: Session Number: iSCSI Session Type: Initiator Name: Target Name: ISID: fosConfig, iscsiCfg, iscsiSessionCfg 0 0 0 0 0 0 17 2576 17 1352 1 Normal iqn.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 406 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 435
Port Leading Connection Switch Port 1 2743 Yes 8/ge4 Security Details CHAP Username: none FC Details Number of FC targets: 1 FC Target Information Index FC WWN 1 2f:df:00:06:2b:0d:10:b9 iSCSI Operating Login Parameters: Session Level Parameter Name Self Value Peer Value Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 436
Length First Burst Length Max outstanding R2T Default time to retain Default time to wait Error recovery level Initial Abort Task Set: 0 iSCSI Clear ACA: 0 iSCSI Clear Task Set: 0 iSCSI LUN Reset: 0 iSCSI Target Reset: 0 iSCSI Task Reassign: 0 Non FCP in PDU: 0 Non FCP in Octet: 0 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 437
-s slot number | all iscsiswcfg --modifygw -t target name iscsiswcfg --showgw Description Use this command to display the iSCSI switch level configuration and to configure the iSCSI connection redirection and target name prefix. Note The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 438
• Bandwidth • Trunking enabled, if applicable • QoS enabled, if applicable When issued on a switch that is part of a logical fabric configuration, the islShow command displays logical interswitch links (LISLs) along with regular ISLs. However, speed (sp) displays N/A for logical ports. The bandwidth - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 439
parameter only supports Brocade FC4-16IP blades in Brocade 48000 directors. Specifies the IP address in dotted-decimal form. Examples To set the IP address of an external iSNS server with an attached GbE port: switch:admin> isnsccfg --set 7/ge0 -s 192.168.131.124 iSNS client configuration updated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 440
isnscCfg See Also To register the iSNS objects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none 412 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 441
it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists use the default slot 0. • No list type except for user port lists may specify multiple conflicting slot numbers. For instance, "1/0, 2/0, 3/0" is a valid user port list but is not valid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 442
which user-accessible external ports within the current switch (selected during Telnet login) are tested. When specified in an item list, user ports might be specified by either the area portion of the ports Fibre Channel address or with slot/port notation. For non-blade systems, the port number on - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 443
serial port login sessions and information such as session number, login name, idle time, IP address of USER TTY IDLE FROM LOGIN@ ~ 0 root0 ttyS0 1:17m - 5:13pm 1 admin0 pts/1 3.00s 192.168.130.29 6:31pm Enter Session Number to terminate (q to quit) q See Also none Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 444
server role to one of the default roles available on a switch. This command also provides an option user belonging to that group to login to the switch with the permissions associated with the mapped switch role. This command supports one-to-one role mapping only. For example, you might map the "SAN - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 445
role to the switch role of "operator": switch:admin> ldapcfg --maprole SANoperator operator LDAP role SANoperator has been successfully mapped. switch:admin> ldapcfg --unmaprole SANoperator LDAP role SANoperator has been successfully unmapped. aaaConfig, userConfig Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 446
chassis context. Each logical switch displays only the user ports that are configured to be part of that switch instance. The switch context is defined by the fabric ID. The default context is the base logical switch that you are placed in upon login. The default logical switch context is defined by - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 447
OS v6.2.0 or later. Refer to the Fabric OS Administrator's Guide for specific hardware support. You cannot use the portEnable command on logical ports. Use lfcfg with the --lislenable option to re-enable disabled LISL ports on a logical switch. Operands This command has the following operands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 448
WWN: 10:00:00:60:69:e2:09:ff Base Switch WWN: 10:00:00:60:69:e2:09:ff Base Domain: 24 Number of Partitions: 2 Logical Switch: 1 Fabric Id: 2 Switch WWN: 10:00:00:60:69:e2:09:fc State: Online(1) Logical Switch: 2 Fabric Id: 3 Switch WWN: 10:00:00:60:69:e2:09:fd State: Online(1) Chassis - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 449
LISLs in the chassis: switch:admin> lfcfg --showall -lisl FID Port# remote-domain Name State 2 384 24 sw0 PT Online 3 385 24 sw0 PT Online See Also FID Port# remote-domain Name State 2 384 24 sw0 PT Online 3 385 24 sw0 PT Online . none lfCfg 2 Fabric OS Command Reference 421 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 450
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 451
restrictions that may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display license commands: switch:admin> licensehelp licenseadd licensehelp licenseidshow licenseremove licenseshow Adds license keys to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 452
Use this command to display the license ID of the system. Some features of the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. This command displays the system license ID used - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 453
to adjust to specific site requirements. These options are used in the case where there are more online ports than the purchased POD licenses can support. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 454
POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports assigned to the second POD license: 10, 11, 12, 13, 14 [Note: these ports cannot be activated due to an insufficient number of installed POD licenses - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 455
been removed and the licensed product uninstalled. After removing a license key, the switch must be rebooted. With no license key, licenseShow displays "No licenses." Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 456
of licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. For temporary are installed, the command displays "No license installed on this switch." Note The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 457
positive number. The FSPF protocol compares the cost of various paths between a source switch and a destination switch by adding default, "static" cost for any port except EX/VEX ports. Use fcrRouterPortCost to configure EX/VEX ports. The execution of this command is subject to Virtual Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 458
Cost 500 (STATIC) To delete the cost value and reset to default: switch:admin> linkcost 2/4 0 To display the change: switch:admin> linkcost 2/4 Interface2/4 Cost 1000 See Also interfaceShow, lsDbShow, topologyShow, uRouteShow, fcrRouterPortCost 430 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 459
that may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout Fabric OS Command Reference 431 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 460
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login 432 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 461
information (information about the devices in the zone) is provided for each LSAN zone. The default output displays only WWNs of the zone members. Search parameters -f, -w, and -z allow searching for LSAN zones based on fabric ID, WWN of an LSAN zone member, or LSAN zone name. "No LSAN zone found - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 462
Also To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: lsan_fcr10_0 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e 10:00:00:00:c9:2b:6a:68 21:00:00:20:37:18:22:55 Fabric ID: 5 Zone Name: lsan_fcr11_0 10:00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 463
be deleted. All switch ports not explicitly assigned to a logical switch are part of the default logical switch. The logical switch feature allows you to configure multiple logical fabrics on top of a base (physical) fabric. Each logical fabric is made up of logical switches that share the physical - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 464
configured. This command prompts for confirmation, indicating that the specified ports will be disabled. The following operands are supported: FID Specifies the fabric ID of the logical switch. This operand is required. -slot slot | slot_range Specifies the slot number or a range of slot numbers - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 465
to continue. To assign ports to a logical switch without confirmation: switch:admin> lscfg --config 2 -port 0-4 -force Configuration change successful. Making this configuration change. Please wait... Please enable your ports/switch when you are ready to continue. Fabric OS Command Reference 437 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 466
logical switch configuration: switch:admin> lscfg --show Created switches: 128(ds) 1(bs) 2 Port 0 1 2 3 4 5 6 7 8 9 FID 1| 1| 1| 1| 1| 1| 1| 1| 2| 2| Port 10 11 12 13 14 15 16 17 18 19 FID 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | Port 20 21 22 23 24 25 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 467
> lscfg --change 1 -base Creation of a base switch requires that the proposed new base switch on this system be disabled. Would you like to continue [y/n]?: y Disabling the proposed new base switch... Disabling switch fid 1 Please enable your switches when ready. lfCfg, setContext Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 468
state database record for switches in the fabric or for a switch. Pointer to LSR. Number of LSRs accepted, even though they were not sufficiently spaced apart. Number of LSRs not accepted because they were not sufficiently spaced apart. Last time an LSR was ignored. Time this LSR was installed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 469
other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default cost for a 1 Gbps link is 1,000. Always 0. Always 1. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 470
length = 60 chksum = 0x168a linkCnt = 2, flags = 0x0 LinkId = 91, out port = 28, rem port = LinkId = 91, out port = 29, rem port = 28, cost = 500, costCnt = 0, type = 1 29, cost = 500, costCnt = 0, type = 1 interfaceShow, nbrStateShow 442 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 471
switch. The logical switch is identified by its fabric ID (FID). The commands you can execute are defined by the role of the account that executes the command. The FID must be part : ON LS Attributes: [FID: 20, Base Switch: No, Default Switch: Yes] Area Port Media Speed State Proto 0 0 id N8 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 472
2 fosExec 19 19 id 22 22 id 23 23 id 24 24 id 25 25 id 26 26 id 27 27 id 28 28 id 29 29 id 30 30 id 31 31 id No_Light N8 No_Light N8 No_Light N8 No_Light N8 No_Light N8 No_Module N8 No_Module N8 No_Module N8 No_Light See Also setContext, userConfig 444 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 473
switch, as well as the shared memory and buffers used by the kernel. Note The execution of this command is subject to Virtual Fabric default, memory usage is displayed in bytes. Examples To view the memory usage: switch:admin> memshow total used Mem: 129740800 112562176 Swap: 0 0 switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 474
switch in the fabric: switch:admin> mscapabilityshow Switch WWN Capability Switch Name 10:00:00:60:69:20:15:71 0x0000008f "switch1"* 10:00:00:60:69:00:30:05 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 475
Use this command to configure the MS Access Control List (ACL). The MS allows a Storage Area Network (SAN) management application to retrieve and administer the fabric and Interconnect Elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 476
list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node WWN select : (0..3) [1] 0 done ... msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow 448 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 477
"Command Availability" for details. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java.sun.com/products/plugin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 478
Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the MS platform service database control block: switch .enabled == 1. See Also msCapabilityShow, msConfigure, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 450 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 479
" for details. This command is supported only in AD0 and AD255 contexts. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like to continue - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 480
reboots. Notes By default, the MS platform service is disabled. Before issuing this command, run msCapabilityShow to verify that all switches in the fabric support the MS platform service; if one switch does not support the service, the command fails. When an FCS policy is enabled, this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 481
This command is supported only in AD0 and AD255 contexts. Operands none Examples To deactivate the MS platform service on all switches in the fabric: switch:admin> msplmgmtdeactivate MS Platform Service is currently enabled. This will erase MS Platform Service configuration information as well - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 482
attached switches) to support request node identification data (RNID) extended link service (ELS). When an FCS policy is enabled, and this command is issued with the "ALL" operand, it can be issued only from the primary FCS. The execution of this command is subject to Virtual Fabric or Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 483
mstdenable ["ALL"] Description Use this command to enable the MS topology discovery service on the local switch or throughout the fabric. The change takes effect immediately and commits to the configuration database for all affected switches. The change is persistent across power cycles and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 484
Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable 456 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 485
login session. The login session gives details of the following: • CP/switch (or console/serial port) used to log in. • The IP address of the current login session for Telnet or the name of the current console port or the serial port (if modem login used). • The current CP mode (Active, Standby, or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 486
about fabric shortest path first (FSPF) neighbors to the local switch or information about a neighbor to a specified port. FSPF can route frames only if the neighbor is in full state. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 487
nbrStateShow 2 Examples To display information about a neighbor directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow Fabric OS Command Reference 459 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 488
number of the port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, FSPF statistics are reset. Examples To display the counters on a port: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 489
To reset the counters on a port: switch:admin> nbrstatsclear 1/0 To verify the changes: switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface 0 data structure: nghbP ifNo masterPort defaultCost cost = 0x1004ce68 = 0 = 0 (self) = 500 = 500 (output truncated) See Also interfaceShow, - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 490
of one or two hexadecimal numbers between 0 and ff, with switch:user> nodefind a320 Local: Type Pid COS PortName NodeName SCR NL 0314d9; 3;22:00:00:04:cf:5d:dc:2d;20:00:00:04:cf:5d:dc:2d; 0 FC4s: FCP [SEAGATE ST318452FC 0001] Fabric Port Name: 20:14:00:60:69:80:04:79 Permanent Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 491
ST336605FC 0003] Fabric Port Name: 20:14:00:60:69:80:04:79 Permanent Port Name: 22:00:00:04:cf:9f:26:7e Device type: Physical Target Port Index: switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL 020eef; 3;20:00:00:e0:8b:01:ce:d3;20:00:00:e0:8b:01:ce:d3; Fabric Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 492
• Physical - Device connected to the Nx_Port, using FLOGI to log in to the switch. • Virtual - Contrived device by the switch. • NPV - Device connected to the Nx_Port, using FDISC to log in to the switch. • iSCSI - Device connected to the iSCSI port. 464 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 493
nsAliasShow 2 The second part indicates the role of the device. Currently, four roles are defined: • the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 494
has 6 entries } To display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 495
Fabric Port Name: 20:04:00:60:69:01:44:22 Permanent Port Name: 21:00:00:ad:bc:04:6f:70 Device type: Physical Target Aliases: The Local Name Server has 6 entries } See Also nsAllShow, nsShow, switchShow nsAliasShow 2 Fabric OS Command Reference 467 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 496
-IP type device Other FC-PH types are displayed in the format "x ports supporting FC4 code," where x is the number of ports of a type and code is the FC-PH type code. Examples To display all devices in the fabric, followed by all type 8 (SCSI-FCP) devices and all type 5 (SCSI-FCIP) devices: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 497
for that domain number. For each device found in the devices list, the following information is displayed: Type U for unknown, N for N_Port, NL for NL_Port. Pid The 24-bit Fibre Channel address. COS A list of classes of service supported by the device. PortName The device's port World Wide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 498
;10:00:00:60:69:00:ab:ba; FC4s: FCIP PortSymb: [28] "SEAGATE ST318452FC 0001" Fabric Port Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 499
to display NS information for all switches in the fabric. Each line of output displays the following information: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 500
Of the two device type parts, the first part indicates the origination of the switch:admin> nsshow { Type Pid COS PortName NodeName TTL(sec) N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10; na FC4s: FCP NodeSymb: [41] "QLA2340 FW:v3.03.06 DVR:v9.0.0.2 (w32 IP)" Fabric Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 501
name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10; 1 FC4s: FCP NodeSymb: [41] "QLA2340 FW:v3.03.06 DVR:v9.0.0.2 (w32 IP)" Fabric Port Name: 20:01:00:05:1e:34 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 502
in the entire fabric. Use the -a option to display online zoned device data for each local device. The command output displays the following information: Type U - known, N - N_Port, NL - NL_Port. Pid The 24-bit Fibre Channel address. COS A list of classes of service supported by the device - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 503
about all the online devices zoned with the given device: switch:admin> nszonemember 0x0416e2 3 local zoned members: Type Pid COS PortName NodeName SCR NL 041901; 2,3;10:00:00:00:c9:26:0e:ae;20:00:00:00:c9:26:0e:ae; 3 Fabric Port Name: 20:09:00:60:69:50:06:78 Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 504
Aliases: hds9200_6p4 hds9200_6p4 Port: 14 Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Zoned Members: 2 devices Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 505
to other switches in the fabric, the switches must be configured to accept the password database with the fddCfg command. The password database is distributed manually with the distribute command. If RADIUS authentication is enabled, password change is blocked for users changing their own - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 506
error messages. Refer to the Fabric OS Message Reference for more diagnostic information. RADIUS enabled error Password change disallowed, RADIUS authentication is enabled. Password error Password length, strength, or history policy not met. "user" is not a valid user name You have not specified - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 507
. You must wait longer to change your password. You cannot change the password before the minimum aging period expires. Password contains invalid characters. The password you entered contains invalid characters. See Also login, logout, passwdCfg Fabric OS Command Reference 479 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 508
password expiration policy is enforced across all user accounts except the root and factory accounts. Account Lockout Policy The account lockout policy disables a user account when the user exceeds a configurable number state. The account lockout 480 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 509
--showall Displays all the password configuration parameters. --set Configures a specified password policy. The following arguments are supported: -lowercase value Specifies the minimum number of lowercase alphabetic characters that must occur in the password. The default value is 0. The maximum - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 510
is displayed. The valid range for -warning is 0 to 999. The default value to 0. -lockoutthreshold value Specifies the number of times a user can specify an incorrect password during login before the account is locked. The number of failed login attempts is counted from the last successful login - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 511
already enabled and sets the config parameter "passwdcfg.adminlockout" to 0. By default, admin lockout policy is disabled. --setdefault Resets all password policies to their default values. --help Displays command usage. Examples To display the current password configuration parameters: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 512
The -history value must be between 1 and 24. minpasswordage value out of range The -minpasswordage be between 0 and 999. invalid password expiration specification The -minpasswordage value or 40. sequence value out of range The -sequence value must be between 1 and 40. passwd, userConfig 484 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 513
calculated continuously in real-time. Each switch represents one hop of the total path. In a Virtual Fabric environment, pathInfo displays port numbers beyond physical port numbers while displaying information for a hop that corresponds to a path in the base fabric. The cost for this hop is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 514
frames. For hop 0, this is source_port. For bladed systems and ports above 256, this parameter is the port index; otherwise, it is the port area. Domain ID The domain ID of the switch. Name The name of the switch. Out Port The output port that the frames take to reach the next hop. For the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 515
is specified as the port index; otherwise, it is the port area. The embedded port (-1) is the default. The embedded port can be selected manually by entering the value of MAX_PORT. MAX_PORT stands for the maximum number of ports supported by the local switch. Fabric OS Command Reference 487 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 516
prompts for the following parameters: max hops The maximum number of hops that the pathInfo frame is allowed to traverse; the default is 25. Fabric Id Specifies the Fabric ID. If unspecified, the value defaults to -1 (Default switch FID 128) basic stats Whether basic statistics are generated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 517
environment (the cost for this hop is the cost of the corresponding path in the base fabric): switch:admin> pathinfo 13 4 Target port is Embedded Hop In Port Domain ID (Name) Out Port BW Cost 0 4 9 2009* - 1500 1 2015* 10 8 1G 1000 2 6 13 E - - To display basic and extended - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 518
0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 490 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 519
displays output from the latest panic dump file available on the switch. If a panic dump file is specified as an argument, the contents of that specific file are displayed. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 520
number, which can be used to manipulate performance monitors. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 521
and DestID both cannot be 0x000000. Examples To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. To add an end-to-end monitor to an Encryption switch: In this scenario, one target disk storage device connects - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 522
VT VI ---> Target 0x01a000 0x0a2001 0x0a2002 0x0a0100 3. Add an EE monitor on port 1 between the Initiator SID and the virtual initiator DID: EncryptionSwitch:SecurityAdmin> perfaddeemonitor 1 0x0a0100 0x0a2002 End-to-End monitor number 0 added. 494 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 523
End-to-End monitor number 1 added. 5. Display the EE monitors on the Encryption Switch: EncryptionSwitch:SecurityAdmin> perfmonitorshow --class EE 1 There are 2 end-to-end monitor(s) defined on port , perfDelEEMonitor, perfMonitorClear, perfMonitorShow Fabric OS Command Reference 495 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 524
. The default alias is "IP Frame". Examples To add an IP monitor to a port: switch:admin> perfaddipmonitor 1/4 IP_MONITOR IP traffic frame monitor #0 added See Also perfAddEEMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor 496 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 525
SCSI Read command. perfaddreadmonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP Read commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 526
write commands. perfaddrwmonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP Read and Write commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 527
of valid keys and user-defined aliases. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 528
of valid keys and user-defined aliases. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 529
. This operand is optional. By default, the alias is an empty string. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added As a special case - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 530
write command. perfaddwritemonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP write commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 531
the previously saved end-to-end and filter configuration settings of performance monitoring from nonvolatile memory. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 532
overwrites any configuration changes that were not saved. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 533
may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To save the current performance monitoring configuration to firmware: switch:admin> perfcfgsave This will overwrite previously saved Performance Monitoring - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 534
" for details. This command is not supported on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 535
an end-to-end monitor on a port, or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL EE monitors on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfMonitorShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 536
monitors from the port: switch:admin> perfdelfiltermonitor 2/3 4 The specified filter-based monitor is deleted. switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no] y See Also perfAddUserMonitor, perfMonitorShow 508 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 537
an end-to-end monitor Delete filter-based monitor Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for end-to-end monitors Get ALPA CRC count by port and ALPA Show the current end-to-end mask Install Top Talker monitor See Also none Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 538
EE 1/2 This will clear ALL EE monitors' counters on port 2, continue? (yes, y, no, n): [no] y To clear statistics counters for a filter-based monitor: switch:admin> perfmonitorclear --class FLT 1/2 4 Filter-based monitor number 4 counters are cleared 510 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 539
monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 540
port. Monitor classes include end-to-end monitors (EE), filter-based number of ports in this ISL (one for a standalone ISL, more for trunks). Num_domains The total number of domains being monitored. Domain_count The 64-bit cumulative transmit counter for each individual domain. 512 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 541
supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric end-to-end), FLT (filter-based), or ISL (interswitch link). These values are case-sensitive. For bladed systems only, specifies the slot number of the port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 542
2 perfMonitorShow To display end-to-end monitors on a port at an interval of every 5 seconds: switch:admin> perfmonitorshow --class EE 8 5 Showing EE port: switch:admin> perfmonitorshow --class FLT 8 There are 2 filter-based monitors defined on port Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 543
perfMonitorShow 2 See Also To display ISL monitor information on a port: switch:admin> perfmonitorshow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports in this ISL: 2 Domain 97: 110379 Domain 98: 13965 Domain 99: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 544
this command to set the mask for an end-to-end (EE) performance monitor. This command allows selecting the Fibre Channel frames for which to collect performance statistics. When setting the EE mask on a port, all existing EE monitors on that port are deleted. This command controls all three address - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 545
mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00: port will cause ALL EE monitors on this port to be deleted. continue? (yes, y, no, n): [no] y The EE mask on port 6 is set and EE Monitors on this port are deleted See Also perfAddEEMonitor, perfShowPortEEMask Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 546
" for details. This command is not supported on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be displayed, followed by - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 547
default value of the EE mask is all fields set to "on." Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 548
2 perfShowPortEEMask RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask 520 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 549
the Brocade 7500. Top Talker supports two modes, Port Mode and Fabric Mode: • In Port Mode, Top Talker is installed on an F_Port to measure the traffic originating from the F_Port and flowing to different destinations. The output displays the data in a sorted order based on the data rate of each - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 550
an existing Top Talker monitor on a specified F_Port. Fabric Mode Top Talker commands: --add fabricmode Installs the Top Talker monitor on all switches in the fabric. When a new switch joins the fabric, this command must be run again on the switch. The TT config information is not propagated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 551
--add fabricmode To delete the Fabric Mode Top Talker: Switch:admin> perfttmon --del fabricmode To display the Fabric Mode Top Talker output: Switch:admin> perfttmon --show dom 1 pid perfttmon --show dom 1 pid Src_PID Dst_PID MB/sec Potential E-Ports 0x03f600 0x011300 121.748 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 552
place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To create PKI objects: switch:admin> pkicreate Installing Private Key and Csr... Switch key pair and CSR generated... Installing Root Certificate... See Also If PKI - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 553
the security functionality of this fibre channel switch. If you want secure mode enabled, you will need to get the switch certificate again. About to remove Pki objects. ARE YOU SURE (yes, y, no, n): [no] y All PKI objects removed. See Also pkiCreate, pkiShow Fabric OS Command Reference 525 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 554
pkishow Description Use this command to display PKI objects, such as switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 555
algorithm. The default is SHA-1. Algorithms include: Secure hash algorithm. Message digest 5. Advanced encryption standard. Valid only with IPSec. Specifies the perfect forward secrecy. This operand is valid only with IKE policies. Values are on (default) or off. Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 556
250000000 or 0. The default is 28800. Examples To create a new policy: switch:admin> policy --create Life (seconds): 28800 IKE Policy 29 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: on Diffie-Hellman Group: 1 SA Life (seconds): 28800 Operation Succeeded 528 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 557
SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. See Also portCfg, portCfgShow, portShow policy 2 Fabric OS Command Reference 529 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 558
(on the base switch and logical switches). On other platforms, the command returns a "not supported" message. Operands This command has the following operands: --bind Assigns the lower two bytes of the Fibre Channel address to the specified port. slot_number Specifies the slot number on bladed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 559
port 24-bit Fibre Channel address: switch:admin>portaddress --bind 5/18 0x1a00 To unbind a given address from a port: switch:admin>portaddress --unbind 5/18 0x1a00 To display all port address bindings on the current partition: switch 24 0x1000 8 bit Fabric OS Command Reference 531 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 560
address binding for port 28: See Also switch:admin>portaddress --show 5/18 Index Slot Port Area Mode 412 5 28 0x1400 8 bit To display the port bound to a specified address. switch:admin>portaddress --findPID 0x2400 Index Port Port ID 36 36 0x 2400 none 532 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 561
Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA type See Also switchShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 562
the port at full bandwidth (depending on the port configuration). If the number of Buffer Usage is less than the number of Needed Buffers, the port is operating in the buffer limited mode. Link Distance For L0 (not in long distance mode), the command displays the fixed distance based on port speed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 563
by a slash (/). portnumber Specifies the number of a port associated with the port group, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Examples To display the port buffer information for a port: switch:admin> portbuffershow 17 User Port Lx Max/Resv Buffer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 564
bladed systems only, specifies the slot number of the port to display, followed by a slash (/). portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. 536 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 565
3 1 350400 2b2200 2b1200 220400 SID Free, DID Free: (61, 511) To display port CAM entries on shared ports: In the following example, port 7/31 and 7/39 are shared ports and 7/31 is the primary port. switch:user> portcamshow 7/39 Area SID used DID used SID entries DID entries 207 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 566
configuration parameters for ports and gigabit Ethernet (GbE) ports. The following operations can be performed with this command: • Optionally add and delete Address resolution protocol (ARP) entries. Flush ARP table. • Create, modify, and delete Fibre Channel over IP (FCIP) tunnels. - Delete, reset - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 567
ARP table. Only dynamic entries can be flushed, static entries cannot be cleared. fciptunnel Creates Fibre Channel over IP (FCIP) tunnels. You can configure up to a maximum of eight FCIP tunnels per GbE port. This feature requires an FCIP license. The syntax for portCfg fciptunnel is as follows - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 568
enabled tunnel can be configured on a port. No other tunnels (IPSec or otherwise) can be configured on the same port. Jumbo frames are not supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. Creates an FCIP tunnel with VLAN Tagging and Class of Service - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 569
Default is 0. -bstr Enables Byte Streaming on the specified tunnel. Byte streaming allows the Brocade switch to communicate with third party WAN optimization hardware. The WAN optimization hardware connects on the GE ports configured for FCIP. The TCP Byte Streaming feature is supported only - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 570
16; default is 8. If Tape Piplelining is enabled, the default value is calculated based on the default Resets/sets VC QoS map to default values. -delete vc_num Deletes associated QoS map configuration file. Delete QoS mappings before downgrading to pre-v6.0.0 firmware versions that do not support - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 571
on a GbE port. After defining the IP interface of the remote switch, you can define destination routes for an interface. A maximum of 40 routes per GbE port are supported. IPv6 addresses are supported on platforms running v6.0.0 or later. You cannot use this command to configure routes for inband - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 572
changes on the port generate an RSCN to another end device that is zoned with this one. By default, RSCN suppression is disabled on all ports. Enables the configuration. When enabled, any device changes on the port will not generate an RSCN to any other end device. 544 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 573
to the mirror port. Port mirroring can aid in troubleshooting common FC end-to-end communication problems. The command prompts for confirmation that the specified port be enabled as a mirror port. Once a port is configured as a mirror port, the port can only be used as part of a mirror connection - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 574
Acknowledgement emulation. This feature is applicable to both FICON Disk and Tape configurations. The feature removes one network round trip for exchanges that end with a Device Level Acknowledgement frame from the device. 1 is enabled, O is disabled. 546 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 575
as emulated commands during write emulation processes. 1 is enabled, O is disabled. The following optional parameter specific arguments are supported with the config and delete options. -a |--wrtMaxPipe value Defines the maximum number of tape write channel commands (CCWs) that can enter the write - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 576
optional feature arguments are supported with the cfg and del options. These configurations are persistent. -a 1|0 Enables or disables ACO. 1 is enabled, O is disabled. The default value is 0. -b Specifies the number of buffers. The range is 0-8. The default value is 0. -e 1|0 -i value -p value - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 577
is 80000C7B. Specifies the trace record size in bytes. The range is 80 to 240 bytes. The default is 80 bytes. inbandmgmt Configures IP addresses and routes for the CP or GbE port inband management interfaces on the Brocade 7500. Inband management allows a management station to communicate with - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 578
VLAN tagging: switch:admin> portcfg fciptunnel8/ge0 modify 1 192.168.10.1 192.168.20.1 0 -m 20 -v 100 To create an FCIP tunnel with Fastwrite and read/write pipelining enabled: switch:admin> portcfg fciptunnel 3/ge0 create 6 10.1.1.44 192.168.131.124 155000 -f -t 550 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 579
ficon ge0 1 -x 1 -w 1 To configure FTRACE with ACo disabled and FTRACE enabled on port ge0/tunnel 3: switch:admin> portcfg ftrace ge0 3 cfg -a 0 -e 1 -p 5 -s 00000003 -t ffffffff To delete the FTRACE on the same port/tunnel: switch:admin> portcfg ftrace ge0 3 del Fabric OS Command Reference 551 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 580
a management station that is on a different subnet (note the added gateway IP address): switch:admin> portcfg inbandmgmt ge0 routeadd 192.168.3.0 255.255.255.0 192.168.1.250 See Also portCfgShow, portCmd, portShow, switchShow, configure, fastWriteCfg 552 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 581
to 0x13. A value of 0 sets the default AL_PA to 0x0. This operand is required. Examples To configure a port with AL_PA 0x0 (default): switch:admin> portcfgalpa 1/3 0 To configure a port with AL_PA 0x13: switch:admin> portcfgalpa 1/3 1 See Also portCfgShow Fabric OS Command Reference 553 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 582
the auto disable feature on a port, on which this feature is already enabled: switch:admin> portcfgautodisable --enable 8 Same configuration for port 8 To enable the auto disable feature on a port range. switch:admin> portcfgautodisable --enable 0-8 554 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 583
enabled. The following example enables port 4. switch:admin> portcfgautodisable --enable 2-4 Same configuration for port 2 Same configuration for port 3 To disable the auto disable feature on a port range. switch:admin> portcfgautodisable --disable 0-8 See Also portCfgShow, portEnable : Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 584
credits or frames to be recovered. Only ports configured as long distance ports can utilize the credit recovery feature. The default credit recovery configuration is enabled. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 585
followed by a slash (/). port Specify the number of the port to be reset to default, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to factory defaults: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 586
slot number of the port to be configured, followed by a slash (/). port Specifies the number of the port to be configured, relative to its slot for bladed systems. Use switchShow to display a listing of valid ports. mode Specify 1 to enable the port as an E_Port. This is the default port state - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 587
can be related to the same edge fabric or to different edge fabrics. When the port is not active, the preferred domain ID is configurable. The preferred domain ID is used by the EX_Port's front phantom domain to request a domain ID from the principal switch. The domain ID received becomes the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 588
values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", the port ID format R_A_TOV and E_D_TOV values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 589
: switch:admin> portcfgexport 2/1 -f 5 -p 1 To configure port 2/0 to be an EX_Port and set the fabric ID to 4: switch:admin> portcfgexport 2/0 -a 1 -f 4 To disable fabric parameter negotiation on port 2/0 of an EX_Port: switch:admin> portcfgexport 2/0 -t 2 To enable IDID on port 2: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 590
To allocate 12 buffers to an F_Port: switch:admin> portcfgfportbuffers --enable 2/44 12 To disable the port buffer configuration and return to the default buffer allocation: switch:admin> portcfgfportbuffers --enable 2/44 12 See Also portBufferShow 562 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 591
designation from the port. A value of 0 is the default port state. Mode must be preceded by a comma. This operand is required. Examples To configure port as a locked G_Port: switch:admin> portcfggport 1/3, 1 See Also configure, portCfgLport, portShow, switchShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 592
enabling ISL R_RDY mode, ensure that all fabric-wide parameters are consistent for every switch in the fabric. Use configshow fabric.ops to view a complete listing of fabric operating mode parameters on the switch. The following E_Port configurations are not applicable to a port configured for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 593
To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow portCfgISLMode 2 Fabric OS Command Reference 565 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 594
" mode due to a lack of frame buffer credits. The number of credits reserved for a port depends on the switch model and on the extended fabric mode for which it is configured. Not all distance modes are supported by all platforms. For example, the FC10-6 only supports LO and LS up to 120 km at 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 595
fill word option is not compatible with QoS configured links and Credit Recovery enabled links. You must disable these features before configuring long distance IDLE fill words. desired_distance On switches running firmware versions earlier than Fabric OS v6.2.0, this parameter controls the long - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 596
configure a switch port 63 to support a 100 km link and be initialized using the long distance link initialization protocol: switch:admin> portcfglongdistance 4/15 LS 1 100 switch Fbsy: 0 configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow 568 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 597
command to designate a port as an L_Port, and to configure its behavior. When a port is designated as an L_Port, the switch attempts to initialize that port as a fabric L_Port (FL_Port). The switch will never attempt a point-to-point (F_Port) initialization on the port. By default the L_Port will be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 598
the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON ON Private L_Port ON Locked Loop HD Loop Fairness See Also configure, portShow, switchShow 570 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 599
IDs are allocated per NPIV port. The maximum number of virtual IDs can be configured from 0 to 255 per port. The default value is 126 per port. The number of virtual port IDs per switch can be configured with the configure command. Refer to the Fabric OS Administrator's Guide for details on NPIV - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 600
Rate Limit Credit Recovery where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 (output from other ports suppressed) To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 See Also configure, portCfgDefault, portCfgShow 572 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 601
if it is connected to an enterprise fabric switch that supports NPIV Notes NPIV capability should be enabled on the ports connected to the Access Gateway. Use portcfgnpivport to enable NPIV capability on the specific port. By default, NPIV is enabled by default on all 4 G and 8 G platforms. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 602
when executed on a persistently disabled port. The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Because the default state of the port is persistently enabled, the persistent disable state is cleared - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 603
or switchDisable commands. The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Notes If this port is connected to another switch, the Fabric may reconfigure. If this port is connected to one or more - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 604
for all ports. --default Applies the default QoS configuration to the specified ports. QoS is enabled by best effort based on availability of buffers. --disable Disables QoS configuration on the specified ports. --enable Enables QoS configuration on the specified ports. --resetratelimit Turns - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 605
the ingress rate limit on a port to 2 Gbps: switch:admin> portcfgqos --setratelimit 3/15 2000 To set the default QoS configuration on a port: switch:admin> portcfgqos --default 3/15 See Also portCfg, portCmd, portShow, switchShow, configure : PortCfgQos 2 Fabric OS Command Reference 577 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 606
interfaces on the GbE port • Static routes on the IP interfaces • Fibre Channel over IP (FCIP) tunnel configuration settings - IKE and IPSec policy information - QoS mappings • Port Mode information • VLAN tag configuration • Inband Management IP addresses and routes configured on the Brocade 7500 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 607
. Displays ON when Quality of Service (QoS) is enabled on the port. Displays (..) or OFF when QoS is disabled. By default, QoS is enabled by best effort based on availability of buffers. This value is set by the portCfgQos command. Displays ON when the port is configured as an EX_Port. Otherwise - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 608
"Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command supports the following port options: slot For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). [ge]port Specifies the number of the port to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 609
ON ON .. .. .. .. Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Port Mirror Port FC Fastwrite Rate Limit Credit Recovery ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Port Auto Disable ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID, LM:L0.5 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 610
display the configuration settings for a single port: switch:admin> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO AL_PA Offset 13: OFF Trunk Port ON Long Interface IPv6 Address Len MTU Arp configuration: IP Address Mac Address 582 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 611
59 4 Tunnel ID 1 Remote IP Addr 192.168.60.181 Local IP Addr 192.168.60.101 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:80:65 Compression on Fastwrite off Tape Pipelining 3 15 3 7 31 0 11 47 4 15 63 0 Vlantag configuration Fabric OS Command Reference 583 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 612
.1 100 7 192.168.10.1 App 192.168.10.1 100 3 0.0.0.0 Perm To display inband management interfaces configured on the Brocade 7500: switch:admin> portcfgshow inbandmgmt ge1 Inband management: Enabled Port: ge1 CP Interface IP Address NetMask MTU 0 192.168.255.1 255.255.255.252 1500 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 613
re-enables the port, and the port comes online with the new speed setting. The configuration is saved in nonvolatile memory and is persistent across switch reboots or power cycles. Use the portShow command to display actual port speed levels. Use the portCfgShow command to display user-specified - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 614
on the port. This operand is required. Trunking is enabled by default, when a trunking license is present on the switch. Examples To enable a port for trunking: switch:admin> portcfgtrunkport 1/3, 1 See Also portCfgShow, portShow, switchCfgTrunk, portTrunkArea, switchShow 586 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 615
negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", R_A_TOV and E_D_TOV display "Not Applicable". By default, all VEX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", port ID format, R_A_TOV, and E_D_TOV display - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 616
interoperability modes with the interopMode command. Examples To display the VEX_Port configuration of port 2/16: switch:admin> portcfgvexport 2/16 Port 2/16 Admin: State: Pid format: Edge Fabric ID: Front Domain ID: info enabled OK core(N) 16 160 588 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 617
E_D_TOV: 2000(N) Edge fabric's primary wwn: N/A Edge fabric's version stamp: N/A To set the fabric ID of port 2/21 to 5 and the port ID format to core: switch:admin> portcfgvexport 2/21 -f 5 -p 1 To configure port 2/20 as a VEX_Port and set the fabric ID to 4: switch:admin> portcfgvexport 2/20 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 618
entry is dynamically maintained by the ipperf application. End-to-end path characterization is not supported if there exists an IPSec-enabled tunnel using the same source/local IP address. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 619
end-to-end IP path performance based on the data rate configured for a tunnel between the same end-points IP address from one of the source IP interfaces on the GbE port. Valid arguments include: Specifies the source IP address that originates the ping request. IPv6 addresses are supported. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 620
dst_ip Specifies the destination IP address to which to target the ping request. IPv6 addresses are supported. -n num_requests Specifies the number of ping requests. Valid values are 1 to 255. The default is 4. This operand is optional. -q service_type Specifies the type of service in the ping - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 621
Specifies Class of Service/Priority, as defined by IEEE 802.1p. Values must be in the range 0 to 7. The default is 0. This operand is optional. with the -v option. Examples To verify if packets can be sent to the destination IP address with maximum wait_time specified: switch:admin> portcmd --ping - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 622
level to be set for port modules; valid values are 1 to 5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 594 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 623
port Specify a port number to be disabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, portShow, switchShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 624
port Specify a port number to be enabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To enable a port: switch:admin> portenable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portDisable, portShow, switchShow 596 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 625
end Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display error counters for ports on a switch: switch 0 0 0 0 0 0 0 0 4 0 0 5: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 6: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 7: 1.6k 24 0 0 0 0 0 0 11 0 0 4 8 0 0 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 626
0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 16: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 17: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 18: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 19: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 (output truncated) See Also portShow, portStatsShow 598 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 627
may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 628
has the following operands: -npass count Specify the number of times to perform this test. The default value is 10. -ports itemlist Specify a list of user ports on which to run the test. If omitted, all the active ports in the switch are assumed. For more information, refer to the itemList - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 629
the port log is disabled, portLogClear enables it. The port log Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 630
restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 602 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 631
restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference 603 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 632
following message displays as the first line: WARNING: port log is disabled Refer to the portLogClear command for more information. For a full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. Notes The execution of this command is subject to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 633
. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: portid Specify the port area or index number. Examples To display the port log dump for a port: switch:user> portlogdumpport 14 time task - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 634
restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log facility: switch:admin> portlogenable See Also portLogDisable 606 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 635
to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display information about port log events: switch:admin> portlogeventshow ID Event-Name Disabled 1 start 0 2 disable 0 3 enable 0 4 ioctl 0 5 Tx 0 6 Tx1 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 636
24-bit Port ID of the attached device. WorldWideName The port's World Wide Name. credit The credit for this login as appropriate. This is BB (buffer-to-buffer) credit for Flogs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 637
set or clear the debug_pdisc_flag. This command is part of the environmental monitor. A setting of 1 will enable logging of Port Discovery parameters. The PDISC log is disabled by default. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 638
of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none 610 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 639
Description Use this command to resize the port log to a specified number of entries. If the specified number of entries is less than the already configured port log size, there is no change. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 640
Possible events include: start A switch start or re-start event. disable A port is disabled. enable A port is enabled. ioctl A port I/O control is executed. . sn Speed negotiation states. fcin Incoming Fibre Channel information unit. 612 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 641
Port Cmd ioctl Tx & Rx scn pstate ctin fc f8 ctout errlog loopscn OLP LIP LIM BMP OLD TMO Args start disable enable Outgoing Fibre Channel Free an exchange. Exchange error. Exchange state. Frame payload. Displays the port number that logged the event. Defined by the event. Displays a value defined - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 642
is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload, if 94 F0F0ARB(F0) timeout. 40 CLS timeout. Codes used in various fields are as follows: state 1 Online 614 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 643
reason 8001 Retry loop init. 8002 Start loop after gaining sync. 8003 Restart loop after port reset. 8004 LIP when a loop hangs. 8005 Restart loop if LIP received when sending out signal. NF Negotiation follows. NC Negotiation complete. Fabric OS Command Reference 615 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 644
the saved log is displayed. This operand is optional. Examples To view the port log for a port: switch:user> portlogshow 24 time task event port cmd args 17:05:30.384 PORT Rx 0 40 02fffffd,00fffffd,08fbffff,14000000 17:05:30.384 PORT Tx 0 0 c0fffffd,00fffffd,08fb0e02 17:05:30.384 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 645
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: portid Specify the number of the port for which to display the log. Examples To display a port log for port 14: switch:user> portlogshowport 14 time - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 646
values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 618 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 647
corresponds to the port log type to be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 648
Synopsis Performs a functional test of port N->N path. portloopbacktest [--slot number][-nframes count][-lb_mode mode][-spd_mode mode] [-ports itemlist] Description Use this command to verify the functional operation of the switch by sending frames from the port N transmitter and looping them - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 649
has the following operands: --slot number Specifies the slot number on which to run the diagnostics. The ports specified will be relative to this slot number. The default is 0 and designed to operate on fixed-port-count products. -nframes count Specifies the number of frames to send. The test - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 650
2 portLoopbackTest TIMEOUT XMIT See Also itemList Did not receive a frame in the given timeout period. Frame transmission failure. 622 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 651
is not online. A connection that is "Enabled" has been configured in the hardware. A new connection cannot conflict with a "Defined" or "Enabled" port mirror connection. Use the portCfgShow command to display all configured mirror ports on a switch. Fabric OS Command Reference 623 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 652
cannot both be 0x000000. Examples To configure a port as a mirror port: switch:admin> portcfg portmirror 2/1 --enable Please confirm enable of Mirror Port: 17 (Y,y,N,n): [n] y To add a port mirror connection between two local switch ports: switch:admin> portmirror --add 2/1 0x011400 0x012400 To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 653
delete 0x011400 0x240400 To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow Fabric OS Command Reference 625 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 654
chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). portnumber Specify a port number to be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 655
of time. In this case, the portPerfShow output on the VE link may not match the output on the device port. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Total slot 1: 0 0 23k 0 0 134k 0 12m 0 7.3m 0 312m 0 1.1g 0 0 1.4g slot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 656
, this table typically has only Bit 16 set (value 0x10000), indicating this port always routes broadcast frames to the embedded port, for handling by the firmware. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 657
switch:user> portrouteshow 4/15 port address ID: 0x02bf00 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 658
the command displays specific FCIP related port configuration parameters, such as the following: • Address resolution protocol (ARP) entries • IP interfaces on the GbE port • Static routes on the IP interfaces • Fibre Channel over IP (FCIP) tunnel configuration settings • FCIP tunnel statistics and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 659
. portId The port's 24-bit port ID. portIfId The user port's interface ID. portWwn The port's World Wide Name. portWwn of devices(s) connected The World Wide Port Names of connected devices. Distance The port's long-distance level. In case of LD mode, the user configured distance and actual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 660
the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. Includes the domain ID and WWN of the principal switch. BB XLate Information on the xlate (translate) phantom domain presented at this port. Includes the preferred (if not - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 661
and F_BSYs generated. For L_Ports, the third column also displays the number of loop initialization protocols (LIPs) received, number of LIPs transmitted, and the last LIP received. In Fabric OS v6.2.0 or later, each GbE port is associated with a TCP history, which tracks the state of statistics - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 662
Streaming feature. Byte streaming allows the Brocade switch to communicate with third party WAN optimization hardware number of times the maximum allowable number of segments was pulled from TCP. Reached Max Pending FramesCount of the number of times the pending frames queue was full. 634 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 663
the L_Ports or NPIV Ports is a part of the current AD, the complete device information attached to the port is shown in the output. Operands This command supports the following port options: slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 664
post display statistics; requires a preceding argument. vlantag Displays VLAN tag configuration settings. ftrace FTRACE is a debug tool for developers and support (not intended for customer use). For usage information, execute portShow ftrace. 636 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 665
0 Port part of other ADs: No To view xlate domains, you must be running a Brocade 7500 or a chassis with an FC4-18i blade. Note that the Front Domain ID is what is shown: switch:admin> portshow 8/4 portName: portHealth: No Fabric Watch License Authentication: None EX_Port Mode: Enabled Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 666
Delim_err: 0 Address_err: 1 Lr_in: 2 Lr_out: 2 Ols_in: 0 Ols_out: 2 Frjt: 0 Fbsy: 0 Port part of other ADs: No To display IPv4 interfaces on a GbE port: switch:admin> portshow ipif 10/ge0 Slot: 10 Port: ge0 Interface IP Address NetMask MTU 0 192.168.60.100 255.255.255.0 1500 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 667
for the data and control TCP connections of Tunnel 0): switch:admin> portshow fciptunnel -all -params Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 192.168.10.2 Local IP Addr 192.168.44.9 Remote WWN Not Configured Local WWN 10:00:00:05:1e:38:84 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 668
Configured TCP Byte Streaming on Status : Inactive Connected Count: 0 Port: ge1 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 192.168.10.10 Local IP Addr 192.168.10.2 Remote WWN Not Configured .10.10:3226 640 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 669
switch:admin> portshow fciptunnel 9/ge0 0 -perf Slot: 9 Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured stats: 44862 output packets Fabric OS Command Reference 641 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 670
port: switch:admin> portshow fciptunnel 9/ge0 0 -ipsec Slot: 9 Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured SA Life (seconds): 28800 642 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 671
Switch:admin> portshow fciptunnel ge1 0 -hist Port: ge1 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 192.168.114.2 Local IP Addr 192.168.114.1 Remote WWN Not Configured 3225 Thu May 29 17:03:10 2008| Fabric OS Command Reference 643 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 672
0 0 1 0 0 0| To reset the TCIP statistics: Switch:admin> portshow fciptunnel ge1 0 -snapstart Port: ge1 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 192.168.114.2 Local IP Addr 192.168.114.1 Remote WWN Not Configured Local WWN 10:00:00:05:1e - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 673
switch:admin> portshow fciptunnel 9/ge0 0 -credits Slot: 9 Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured :0 overcommitted_count: 0 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 674
80 switch:admin> portshow fciptunnel 9/ge0 0 -qosmap Slot: 9 Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured 4 14 59 4 15 63 0 646 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 675
switch:admin> portshow fciptunnel ge1 0 -bstr Port: ge1 Tunnel ID 0 Remote IP Addr 192.168.32.2 Local IP Addr 192.168.32.1 Remote WWN Not Configured 24 tail index = 24 Current Count = 0 Pending Frames High = 16 Segment Count High = 3 Data Mover Restarts = 0 Data Mover Desc Full - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 676
configured on the 7500: switch:admin> portshow inbandmgmt ge1 Port: ge1 Inband Management: Enabled CP Interface IP Address NetMask MTU 0 192.168.255.1 255.255.255.252 1500 GE Interface IP , portLoginShow, portName, switchShow 648 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 677
Number of frames with CRC errors. er64_trunc Number of frames shorter than minimum. er64_toolong Number of frames longer than maximum. er_bad_eof Number of frames with bad end-of-frame. er64_enc_out Number Tx peak Byte rate (Bps). Fabric OS Command Reference 649 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 678
followed by a slash (/). portnumber Specify a port number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 679
2 er_bad_eof 0 top_int : Frames with bad end-of-frame 0 bottom_int : Frames with bad end-of-frame er64_enc_out 0 top_int : Encoding error words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow Fabric OS Command Reference 651 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 680
a slash (/). port Specify a port number to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To clear hardware statistics for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow 652 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 681
degraded performance (platform- and port-specific). er_enc_in The number of encoding errors inside frames. er_crc The number of frames with cyclic redundancy check (CRC) errors. er_trunc The number of frames shorter than the minimum frame length. Fabric OS Command Reference 653 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 682
. Specify the optional ge option to display the GbE port hardware statistics. Use switchShow to display a list of valid ports. ge Displays the GbE port statistics. ip Displays all GbE port statistics related to IP addresses that are on (not zero). 654 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 683
0 Frames with bad end-of-frame er_enc_out 71 port 1: switch:admin> portstatsshow ge 8/ge1 ge_stat_tx_frms ge_stat_tx_octets ge_stat_tx_ucast_frms ge_stat_tx_mcast_frms 0 GE transmitted frames 0 GE transmitted octets 0 GE transmitted unicast frames 0 GE transmitted multicast frames Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 684
8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 IP CRC Errors 0 IP Checksum Errors 0 IP TCP Data Checksum Errors To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 685
, relative to its slot for bladed systems. Examples To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable, portShow, portSwapDisable, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference 657 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 686
of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not affect previously performed portswap operations. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 687
Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 688
the enabled state of the portswap feature, as well as port and area information for ports whose area number differs from the default area number. The default area number of a port is the same as its switch port number. Note The execution of this command is subject to Virtual Fabric or Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 689
that are enabled for Virtual Fabrics, this test can only be executed from the default switch. Ports that are not on the default switch cannot be tested. Valid port connections for this test are: • From the default switch to legacy switches that do not support Virtual Fabrics. Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 690
the default switch to a switch that supports Virtual Fabrics but has the VF feature disabled. To ensure coverage of all ports, it is recommended that you run portTest before enabling Virtual Fabrics on the switch. It is recommended that you run portTest before you configure the logical switches or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 691
that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all user ports in the current slot is assumed. Refer to the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 692
Trunk Master, Slave, or --. Master Displays the master port of the trunk group. TA On standalone switches, displays the user assigned TA number. DA On standalone switches, displays the default port area. The default area can be a port swapped area. TI On enterprise-class platforms, displays - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 693
I zones referring to these indices are no longer part of the switch. For details and workarounds, refer to the Fabric OS Administrator's Guide. 13. Device Connection Control (DCC) Policy must be removed from ports prior to creating a TA. You can re-enable DCC policy after creating the TA. 14. You - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 694
which masterless F_Port trunking is enabled). disabled Displays configuration details for all ports not included in a user assigned TA (all portson which masterless F_Port trunking is notenabled). all Displays configuration details for all ports on a switch. 666 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 695
the TA. 2. Enable Trunk Area for ports 36 - 39 with area number 37: switch:admin> porttrunkarea --enable 36-39 -area 37 Trunk area 37 enabled for ports 36, 37, 38 and 39. 3. Re-enable ports 36-39 by executing portenable port for each port in the TA. 4. Show switch/port information: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 696
-index 125 Trunk index 125 enabled for ports 10/13 and 10/14. 3. Show the TA port configuration (ports still disabled): switch:admin> porttrunkarea --show enabled Slot Port Type State Master TI DI 10 13 -- -- -- 125 125 10 14 -- -- -- 125 126 668 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 697
Show the TA port configuration after enabling the ports: switch:admin> porttrunkarea --show enabled Slot Port Type State Master TI DI 10 13 F-port Master 10/13 125 125 10 14 F-port Slave 10/13 125 126 portCfgTrunkPort, portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 698
a switch. Output shows virtual port number (decimal), physical port number (decimal), online status, and if online, port type. If the current zone configuration has been disabled by cfgDisable, the fabric is in non-zoning mode, in which all devices see each other. When default zoning is enabled with - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 699
Whenever a power supply goes out of service or a field-replaceable unit (FRU) board processors to cease executing the firmware. For example, if only one power Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To modify the power-off list order: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 700
8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow 672 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 701
a power supply goes out of service or a field-replaceable unit (FRU CP board processors to cease executing the firmware. For example, if only one power Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the slot power off list order: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 702
installed. predicting failure Power supply is present but predicting failure. faulty Power supply present but faulty (no power cable, power switch Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To view the status of the power supplies: switch: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 703
. Synopsis reboot [-f] Description When this command is issued on a switch connected to a fabric, all traffic to and from that switch stops. All Fibre Channel ports on that switch including E_Ports become inactive until the switch comes online. This command prompts for confirmation with the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 704
Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display a list of routing-related commands: switch FSPF (TM) neighbors' states Reset the FSPF (TM) interface counters Display the unicast fabric topology Configure a static route Remove a static - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 705
-capable, the security database is limited to 1 megabyte. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum size is 256 Kilobytes. Notes The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 706
. If switch is configured to do DH-CHAP, it is performed whenever a port or a switch is enabled. Warning: Please use a secure channel for setting secrets. Using an insecure channel is not safe and may compromise secrets. Following inputs should be specified for each entry. 678 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 707
setting up shared secrets > Enter WWN, Domain, or switch name (Leave blank when done): 10:00:00:60:69:80:05:14 Enter peer secret: Re-enter peer secret: -CHAP secret keys. If a fabric requires authentication, deleting this database may cause switch to segment from the fabric. Do want to remove secret - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 708
[-enable https]] [-protocol ftp | scp] [-ipaddr IP address] [-remotedir remote directory ] [-certname certificate name] [-login login name] [-password password] seccertutil show [-ldapcacert] | [file name] Description Use this command to manage third-party certificates on a switch, including - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 709
file named ip_address.csr, where ip_address is the IP address of the switch. -country country code Specifies the country. Provide locality locality Specifies the city. Provide the full name, for example, "San Jose". If the locality consists of multiple Fabric OS Command Reference 681 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 710
SCP. -ipaddr IP address Specifies the IP address of the remote host. -remotedir remote directory Specifies the remote directory. Provide a fully qualified path name. -login login name Specifies the login name for the server. -password password Specifies the password for the user account. When using - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 711
secCertUtil 2 -password password Specifies the password for the user account. When using SCP, for security reasons, do not enter a password on the command line. Use the interactive version instead. show Lists all existing PKI-based certificates on the switch. The following operands are optional - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 712
. To import a PKI-based certificate with configure and enable option in non-interactive mode: switch:admin> seccertutil import -config swcert -enable https -protocol ftp \ -ipaddr 195.168.38.206 -remotedir /users/home/remote_certs -certname file.crt \ -login abcd -password passwd Success: imported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 713
ldap ca certificate files: Sample.cer To display the content of the CSR one page at a time: switch:admin> seccertutil showcsr | more To display the content of a certificate: switch:admin> seccertutil show certificate_name See Also none secCertUtil 2 Fabric OS Command Reference 685 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 714
, the security database is limited to 1 Megabyte. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum size is 256 Kilobytes. The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version of the operating - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 715
----The latest RCS STATUS---RCS was enabled sec_aca: free RCS latest Phase: Completion RCS Message ==> RCS transaction completes. ----DataBase STATUS---Retry Role 0 Retry Qeury0 Security Active DataSize 35 bytes -----Domain State----- Active Sum 215b Fabric OS Command Reference 687 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 716
secGlobalShow Security Defined DataSize 35 bytes Define Sum 215b Zone Size (include enabled configuration) 312 bytes Zone sum e04b215b sec_db: free primaryDLPhase 0 ----wwnDL completion [Output truncated] See Also secActiveSize, secDefineSize 688 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 717
secpolicysave secpolicyshow secstatsreset secstatsshow Configure FIPS mode operation Creates public policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics See Also none Fabric OS Command Reference 689 53-1001186- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 718
policy creation and modification operations from all the switches if a fabric-wide consistency policy is not set for the particular policy. Notes When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. Only the user who made the changes to the defined database - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 719
Policy Sets. Notes The behavior of this command is the same for tolerant and strict fabric-wide consistency. When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. Any modifications to the SCC, DCC, and FCC DB are saved and activated. When secPolicyActivate - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 720
DCC, SCC and FCS remains unchanged in Fabric OS v6.2.0 and can be configured on a per logical switch basis. Notes When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 721
3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. To add a member to the SCC_POLICY using the device WWN: primaryfcs:admin> secpolicyadd "SCC_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been added to SCC_POLICY - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 722
. Automatic policy distribution behavior for DCC, SCC and FCS remains unchanged in Fabric OS v6.2.0 and can be configured on a logical switch basis. Notes When an FCS policy is enabled, this command can be issued only from the Primary FCS switch. The execution of this command is subject to Virtual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 723
DCC_POLICY does not stop access to the switch. The device is specified by its port WWN. The switch and port combination must be in the switch port format switch can be specified using a WWN, domain, or switch name. port can be specified by port numbers separated by commas and enclosed in either - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 724
. To create a SCC policy in a Fabric with three switches: 1. Check if a policy exists. switch:admin> secpolicyshow ACTIVE POLICY SET DEFINED POLICY SET 2. Identify switches in the fabric. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 2: fffc02 10:00:00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 725
enabled, this command can be issued only from the Primary FCS switch. The execution of this command is subject to Virtual Fabric ports are removed from a logical switch. SCC_POLICY Deletes the Switch Connection Control policy from the defined policy list. FCS_POLICY Deletes the Fabric Configuration - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 726
2 secPolicyDelete To delete all stale DCC policies in the fabric: primaryfcs:admin> secpolicydelete ALL_STALE_DCC_POLICY About to clear all STALE DCC policies ARE YOU SURE (yes, y, no, n): [no] y See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 727
" for details. This command can be issued from all FCS switches in the fabric. Operands This command has the following optional operands: "listtype" name has the common prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have to be capitalize. If - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 728
: switch:admin 4a - Unknown DCC_POLICY_h1 Type WWN DId swName Switch 10:00:00:05:1e:39:5f:67 all security policies in the defined database: switch:admin> secpolicydump "Defined" DEFINED POLICY SET 4a - Unknown DCC_POLICY_h1 Type WWN DId swName Switch 10:00:00:05:1e:39:5f:67 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 729
1e:90:09:4a - Unknown To display the SCC policies in the defined database: switch:admin> secpolicydump "Defined","SCC_POLICY" DEFINED POLICY SET SCC_POLICY WWN DId swName 10:00:00 , secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference 701 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 730
position, it becomes the primary FCS after activation. An FCS policy most be enabled to execute this command, and the command must be issued from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 731
, y, no, n): [no] y secpolicyactivate command was completed successfully. switch:admin> secpolicyshow ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference 703 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 732
devices associated with a specific switch and port combination. The device is specified with a WWN string. The switch and port combination must be specified in the switch port format where switch can be specified by switch WWN, domain, or switch name. The port 704 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 733
all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Examples To remove a member that has a WWN of 12:24:45:10:0a:67:00:40 from SCC policy: switch:admin> secpolicyremove "SCC_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 734
saves the modified SCC, DCC, and FCS policies to the Defined Security Policy Set on the local switch. Notes This command is always a local switch operation. A fabric-wide consistency configuration does not affect the behavior of this command. The execution of this command is subject to Virtual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 735
common prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have switch:admin> secpolicyshow "active ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 736
WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave 708 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 737
This command can be issued on any switch to reset the security statistics on the local switch or chassis. If an FCS policy is enabled and secStatsReset is issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Note The execution of this - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 738
domain IDs on which to reset the security statistics. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains, separated by semicolons and enclosed in quotation marks. This option can only be executed when an FCS policy is enabled and when the command is issued - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 739
. This command can be issued on any switch to display local security statistics. If an FCS policy is enabled and secStatsShow is issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. Note The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 740
Specify an asterisk (*) in quotation marks to represent all switches in the fabric or specify a list of domains separated by semicolons. This option can only be executed when an FCS policy is enabled and the command is issued from the primary FCS switch. When domain is specified, the name operand is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 741
temperature, fan, and power supply status and readings from sensors located on the switch. The actual location of the sensors varies, depending on the switch type. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 742
display currently configured partitions and their FIDs. A logical switch context defines the boundaries within which a user can execute commands in a Virtual Fabric-aware environment. In a Virtual Fabric-aware environment, all commands are context-specific. When a user executes a switch-wide command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 743
. By default, no supported modules and their current debug levels are displayed by the command dbgShow. Note The execution of this command is subject to Virtual Fabric switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug level = 3, verbose level = 0 See Also dbgShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 744
CP modem serial port. When the CP is active and dial-in is enabled, the modem is configured to answer an Fabric OS commands" and Appendix A, "Command Availability" for details. This command is not supported on the Brocade DCX backbone. Operands The optional operands are as follows: -e Enables - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 745
serial console. By default, no debug messages are displayed. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See Also dbgShow, setDbg Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 746
are replaced or removed while a port or a switch is disabled. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may specify the slot number of the port to display, followed by a slash (/) portnumber Specify the number of the port for which to display - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 747
detailed SFP information for a Finisar "smart" SFP: switch:user> sfpshow 1/3 Identifier: 3 SFP Connector: 7 LC uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP Code: 020313 Fabric OS Command Reference 719 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 748
Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Port 1 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 (units 100 megabaud) 720 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 749
Vendor Rev: AA10 Wavelength: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow sfpShow 2 Fabric OS Command Reference 721 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 750
is disabled by default. Because this command changes the flow control on the console serial port, it must be executed from a session that is logged in from the console serial port. This command cannot run from a Telnet session. This setting is saved in the configuration database; therefore, it - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 751
to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To enable flow control: switch:admin> shellflowcontrolenable Enabling flowcontrol flow control is now enabled See Also shellFlowControlDisable Fabric OS Command Reference 723 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 752
: slotnumber Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow 724 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 753
This command has the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff, slotShow Fabric OS Command Reference 725 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 754
52 Core8 switch blade 37 FC8-16 port blade 55 FC8-32 port blade 51 FC8-48 port blade Status Displays the status of the blade as one of the following: VACANT The slot is empty. INSERTED, NOT POWERED ON The blade is present in the slot but is turned off. 726 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 755
Fabric mode, the "User Ports Disabled" information is suppressed, because ports may not physically belong to the switch. ENABLED (SAS Virtualization Disabled) The blade is on, but due to an incompatibility between the FOS image and the SAS or Application image, the SAS Virtualizaion services - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 756
: 9.91 watts per port, 2.48 watts per Gb To display Brocade model names for each blade in a Brocade DCX: switch:user> slotshow -m Slot Blade Type ID Model Name Status 1 AP BLADE 33 FA4-18 ENABLED 2 SW BLADE 55 FC8-32 ENABLED 3 SW BLADE 37 FC8-16 ENABLED 4 SW BLADE 39 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 757
a Brocade DCX-4S: switch:user> slotshow -m lot Blade Type ID Model Name Status 1 SW BLADE 51 FC8-48 ENABLED 2 SW BLADE 39 FC10-6 ENABLED 3 CORE BLADE 46 CR4S-8 ENABLED 4 CP BLADE 50 CP8 ENABLED 5 CP BLADE 50 CP8 ENABLED 6 CORE BLADE 46 CR4S-8 ENABLED 7 SW BLADE - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 758
this command to manage the configuration of the SNMP agent in the switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, system group, and security level settings. The command supports set, reset to default, and display operations. All values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 759
s enabled, community strings can be changed on the primary FCS switch only, and only the primary FCS switch propagates changes across the fabric. For an SNMP management station to receive a trap generated by the agent, the administrator must configure a trap recipient to correspond to the IP address - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 760
--default option sets the user name and password to default. If an FCS policy is enabled, the configuration has to be updated on the primary switch and the nonprimary switches; unlike community strings, user names and passwords are not distributed for other switches in the fabric. When new passwords - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 761
Group Configuration Parameters sysDescr The system description. The default value is Fibre Channel switch. sysLocation The location of the system (switch). The default value is End User Premise. sysContact The contact information for this system (switch). The default value is Field Support - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 762
configured yet To set the SNMPv1 configuration of a switch: switch:admin> snmpConfig --set snmpv1 SNMP community and trap recipient configuration: Community (rw): [Secret C0de] Trap Recipient's IP t, false, f): [true] Committing configuration...done. 734 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 763
configuration to default values: switch:admin> snmpconfig --default systemGroup ***** This command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support (1..3) [1] Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 764
on SNMP: Fabric OS MIB Reference SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 765
do not support Virtual Fabrics. • From the default switch to a switch that supports Virtual Fabrics but has the VF feature disabled. To ensure coverage of all ports, it is recommended that you run spinFab before enabling Virtual Fabrics on the switch. Ports in extended link configurations cannot be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 766
actual number of frames sent will be slightly larger, particularly at link speeds of 4 Gbps or higher. -ports itemlist Specifies a list of user ports to test. By default, all of the ISL ports in the current switch are tested. Refer to itemList for further details. -setfail mode Instructs spinFab - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 767
ERR_STAT_ENCOUT ERR_STAT_TRUNC FINISH_MSG_ERR INIT MBUF_STATE_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT itemList, portLoopbackTest spinFab 2 Fabric OS Command Reference 739 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 768
to enable and manage SSH public key authentication on a switch. SSH public key authentication provides a mechanism for authenticating an authorized user without a password. SSH public key authentication is more secure than password authentication and can be used to securely access services that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 769
Enter the IP address for the remote host. IPv4 and IPv6 addresses are supported. remote directory login name password Enter the path to store the public key. The default directory where SSH stores public keys is ~username/.ssh. Enter the user name for the configured user. Enter the password for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 770
letters, numbers, and IP Address, remote directory, login name and password. Refer to importpubkey for a description of these parameters. delprivkey Deletes the private key for outgoing connection from the switch. This option can only be performed by a configured user. Deletion of a configured user - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 771
sshUtil 2 Password: public key is imported successfully. 3. Connect to switch using remote ssh client with the -i private_key option: username@remotehost> ssh username@switch IP address -i id_dsa To display the imported public keys on a switch: switch:username> sshutil showpubkeys user's public - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 772
for the blade ports specified in -bports clears. A value of zero (0) clears the user ports specified in -uports. The default value is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList 744 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 773
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 774
. Examples To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none 746 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 775
FTP host. Provide an IP address or a server name. IPv4 and IPv6 addresses are supported. To specify the host by name, a DNS entry must exist for the server. -u username Specifies the FTP account user name. The user name must be less than 48 characters long. -p password Specifies the FTP account - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 776
.168.67.126 User Name[njoe]:admin Password[********]:password Remote Dir[support]:temp Auto file transfer parameters changed To set the time interval at which the FTP server connectivity is checked: switch:admin> supportftp -t 24 supportftp: ftp check period changed. To enable auto file transfer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 777
blades installed on the switch, a support file (a.tar.gz file) is generated from each slot. This command accepts IPv4 and IPv6 addresses. If the configured IP address is in IPv6 format, the RAS auto file transfer and event notification to syslog will not work in the case where the Fabric OS version - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 778
. OK to proceed? (yes, y, no, n): [no] y Host IP or Host Name: 192.168.126.115 User Name: admin Password: Protocol (ftp or scp): ftp Remote Directory: /temp/support Saving support information for chassis:HL_5100_66, module:RAS... Saving support information for chassis:HL_5100_66, module:TRACE_OLD - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 779
switch:admin> supportsave -U -d mysupportsave This command will collect RASLOG, TRACE, supportShow, core file, FFDC data and other support support information for chassis:ras095_chassis, module:TRACE_NEW... Saving support information for chassis:ras095_chassis, module:FABRIC... Saving support - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 780
exception Exception group commands, enabled by default. port Port group commands, enabled by default. fabric Fabric group commands, enabled by default. services Service group commands, enabled by default. security Security group commands, enabled by default. network Network group commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 781
:30 2008 Mon Oct 20 16:04:18 2008 1.0.6 supportshow groups enabled: os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon disabled ficon disabled iswitch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 782
:30.131 PORT Tx 0 40 07:32:30.131 PORT Rx 0 0 07:32:41.887 PORT Rx 0 40 07:32:41.887 PORT Tx 0 0 07:32:41.887 FCPH read 0 40 02fffffd,00fffffd, , supportSave, supportShowCfgDisable, supportShowCfgEnable, supportShowCfgShow, traceDump 754 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 783
exception | port | fabric | services | security | network | portlog | systemextend | filter | perfmon | ficon | iswitch | asic_db |iscsi | ag | crypto Description Use this command to disable a group of commands under the supportShow command. Use the supportShowCfgEnable command to enable groups of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 784
the exception group commands. port Enables the port group commands. fabric Enables the fabric group commands. services Enables the service group commands. security Enables the security group commands. network Enables the network group commands. portlog Enables the portlog group commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 785
the command groups that are enabled in the supportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 786
Use this command to enable or disable switch beaconing mode. Switch beaconing can be used to locate a failing unit. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, from port 0 to the highest port number and back to port 0. The beaconing mode continues - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 787
switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch as each port is disabled. A persistently disabled switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch remains disabled - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 788
persistently enable a persistently disabled switch. All Fibre Channel ports that passed the power-on self-test (POST) are enabled and come online if connected to a device, or remain offline if disconnected. The switch may need to be enabled if it was previously disabled to make configuration changes - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 789
across switch reboots or power cycles. Use the portShow command to display actual port speed settings. Use the portCfgShow command to display user-configured speed settings. Notes This configuration cannot be set on VE_Ports or VEX_Ports. The execution of this command is subject to Virtual Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 790
trunking on all ports. Examples To enable trunking on all ports of a switch: switch:admin> switchcfgtrunk 1 Configuration applied to all ports except the following \ VE/VEX_Ports (ports 176 - 191). See Also To disable trunking on all ports of a switch: switch:admin> switchcfgtrunk 0 Committing - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 791
disable all user ports on a switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. As each port is disabled, the front panel LED changes to a slow flashing yellow. The switch must be disabled before making configuration changes or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 792
this command to enable all user ports on a switch. All Fibre Channel ports that passed the power-on self test (POST) are enabled. They can come online if connected to a device, or remain offline if disconnected. Use switchEnable to re-enable the switch after making configuration changes or running - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 793
running earlier firmware versions, the switch name can be up to 31 characters long. On all other pre-Fabric OS v6 numbers, hyphens, and underscore characters. Spaces are not allowed. This operand is optional; if omitted, this command displays the current switch name. Examples To change a switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 794
the fabric ID associated with the logical switch and the switch role (default switch or base switch). The switch summary is followed by one-line description for non-EX_Ports and one or two lines for EX_Ports: Area Part of the 24-bit port ID, which consists of domain, port area number, and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 795
is signaling a laser fault. The port is marked faulty. The port failed diagnostics. The port is locking to the reference signal. The port is running diagnostics. A port connection is not established (for virtual ports only). The port is up and running. Fabric OS Command Reference 767 53-1001186 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 796
. FICON Persistent DID This port has been disabled, because the switch could not obtain its configuration domain ID during the fabric reconfiguration when ficonMode was enabled. See the ficonMode help page for more information. Fabric ID conflict Two different fabrics have been assigned the same - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 797
configured as an N_Port and is online, switchShow displays its type as an N_Port. Also, switchShow displays the WWN of the border switch attached to this N_Port as a 24-bit Port Identifier assigned to this port by the enterprise fabric. In an AD context, if one of the L_Ports or NPIV Ports is a part - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 798
1 switchId: fffc01 switchWwn: 10:00:00:60:69:80:04:92 zoning: ON (testcfg1) switchBeacon: OFF FC Router: OFF Allow XISL use: ON LS Attributes: [FID: 10, Base Switch: No, Default Switch: No] Index Slot Port Address Media Speed State Proto 770 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 799
769 -- -- -- OnlineE-Port 10:00:00:05:1e:40:f0:79 "Switch 1" (logical) 770 -1 770 -- -- -- Offline(logical) 785 -1 785 -- -- -- Offline Disabled (logical, reason why port was disabled) See Also portCfgLongDistance, switchDisable, switchEnable, switchName Fabric OS Command Reference 771 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 800
the default values, if there is one faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. If two ports were faulty, then this contributor would set the overall switch status to DOWN. Note The execution of this command is subject to Virtual Fabric or Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 801
the policy parameter is NOT applicable to the switch. ** Simply hit the Return key. The minimum number of Bad PowerSupplies contributing to DOWN status: (0..4) 448) [0] Policy parameter set has been changed switchStatusPolicyShow, switchStatusShow Fabric OS Command Reference 773 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 802
that trigger a status change in the switch. For example, if the FaultyPorts DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch changes to DOWN. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 803
Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference 775 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 804
Use this command to display the overall status for a switch that is configured with IPv4 and IPv6 addresses. In addition, users with a Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, and the status of the following contributors - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 805
Missing SFPs monitor HEALTHY All ports are healthy To retrieve a switch health report for a switch that is configured with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 806
this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 807
Fabric OS Commands" and Appendix A, "Command Availability" for details. This command can be executed on both active and standby CPs. This command does not support a switch: switch:admin> switchviolation --dump -dcc Device WWN Port 22:00:00:04:cf:75:59:87 10 See Also none Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 808
appropriate log files or users, depending on the system configuration. The specified facility is used when forwarding messages to the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. Note The execution of this command is subject to Virtual Fabric or Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 809
servers are supported. You can specify a syslogd server in one of two ways: • By IP address: The syslogdipadd command accepts IPv4 and IPv6 addresses. • By host name: The host must have a DNS entry and accept DNS requests. You must configure the DNS name service on the switch with dnsconfig before - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 810
2. Add the DNS name server to the switch: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 2 Enter Domain Name: [] brocade.com Enter Name Server IP address in dot/colon notation - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 811
system messages are sent from the syslog server configuration on the switch. IPv6 and IPv4 syslogd addresses are supported. Use syslogdIPShow to view the current syslog server configuration. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 812
. Synopsis syslogdipshow Description Use this command to display all syslog daemon IP addresses in the configuration database. IPv4 and IPv6 addresses are supported. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 813
CP, and any AP blades. After executing this command, manually power off the system. To reboot the system, manually turn the power switch on. Notes This command is not supported on the standby CP. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 814
To attempt a system shutdown from the standby CP (not supported): switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please run the sysshutdown from the active CP See Also haDisable 786 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 815
designed to operate with switches connected to a fabric and restrict the frame loopback to inside the unit. If loopback plugs are installed in all ports, the burn-in parameter min_lb_mode can be changed to 1 to test the Fibre Channel through the loopback plug. Notes The switch must be offline for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 816
To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 817
To display temperature and status sensors: switch:user> tempshow Index Slot State Centigrade Fahrenheit 1 1 Ok 41 105 2 2 Ok 39 102 3 3 Absent 4 4 Absent 5 5 Ok 26 78 6 6 Ok 27 80 See Also fanShow, psShow, sensorShow, slotShow Fabric OS Command Reference 789 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 818
Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: timeval Specify the number switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none 790 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 819
. The following rules apply: 1. On all switches, the command displays the number of domains in the fabric and the local Domain IDs. If translate domains are configured, existing translate domains and associated ports are displayed. 2. On an edge fabric, the command displays the following additional - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 820
all domains, including local domains and local translate domains: switch:user> topologyshow 6 domains in the fabric; Local Domain ID: 7 Domain: Metric: Name: Path Count: 1 10500 fcr_xd_1_1 1 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 2 11 0 1 2 3 4 5 6 7 8 9 15 8.000 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 821
for the three remote domains, not for the two local translate domains. switch:user> topologyshow 5 domains in the fabric; Local Domain ID: 2 Local Translate Domain 4 owned by port: 24 Local Translate Domain 5 owned by port: 23 33 Domain: Metric: Name: Path Count: 1 500 pengsaturn104 1 Hops: Out - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 822
2 topologyShow See Also Path Count: 1 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 2 0 23 24 33 38 39 8.000 Gbps 350 % D fcrXlateConfig, portRouteShow, uRouteShow 794 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 823
is used, the default remote file name format number from which a trace dump is generated. If a slot is not supplied, the trace dump is generated from the local slot. This operand is optional. Examples To initiate a background trace dump from slot 5: switch:admin> tracedump -n -s 5 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 824
2 traceDump See Also To remove a trace dump: switch:admin> tracedump -r trace dump removed supportFtp, supportSave, supportShow 796 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 825
may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 826
optional. Examples To enable the track-changes feature: switch:admin> trackchangesset 1, 1 Committing configuration...done. switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also snmpConfig, trackChangesHelp, trackChangesShow 798 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 827
the feature is enabled or disabled and if SNMP traps are generated. The output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. Note The execution of this command is subject to Virtual Fabric or Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 828
area or index numbers for a port. This operand is required. Examples To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are trunked together See Also portCfgTrunkPort, switchCfgTrunk, trunkShow 800 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 829
are part of this trunking group are displayed. Port to port connections Displays the port-to-port trunking connections. WWN Displays the WWN of the connected port. Domain Displays the domain IDs of the switches directly connected to the physical ports. In case of a FC Router backbone fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 830
16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 4 1 013100 id N4 Online EX-Port 10:00:00:05:1e:35:b3:03 "SW4100_33" (fabric id = 100 )(Trunk master) E-Port 50:00:51:e3:70:bb:af:c1 "fcr_xd_9_100 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 831
enable fabric-wide clock synchronization with the specified clock server. A value of LOCL may be specified as operand to set the clock server back to default. Each ipaddr specified should be the IP address of an NTP server and should be accessible from the switch. The NTP server must support a full - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 832
123.123.123 Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 To configure multiple NTP servers: switch:admin> tsclockserver "12.134.125.24; 12.234.87.01" Updating Clock Server configuration...done. See Also date 804 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 833
, GMT. If all switches in a fabric are located in the same time zone, you may leave the default time zone setup. Time zone is used in computing local time for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 834
the number of the value defaults to 0. setup and then change it to GMT-3:30: switch:admin> tstimezone Time Zone Hour Offset: 0 Time Zone Minute Offset: 0 switch:admin> tstimezone -3, -30 Updating Time Zone configuration 40) St Pierre 7) Belize 24 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 835
Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the offset format and verify the configuration: switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 836
Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following optional operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. All blade ports in the specified slot are tested. This operand is optional. The default - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 837
may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also date - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 838
if this port becomes part of a valid path in the future. If a static route requires hardware resources that are already used, a platform conflict warning message is displayed and the configuration does not take effect. When using static routes, load sharing may be affected. The switch attempts to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 839
a previously configured static route. After this command is issued, the route to domain for in_area might change to use a different output port, but only from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 840
number of local switch. In Port Port from which a frame is received. Except for the cases in which you perform a port swap or enable extended-edge PID (PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 841
for all domains in the fabric is displayed. Examples To display the routing information of all the active ports: switch:admin> urouteshow Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 0 1 11 1000 1 D 1,0 11 2 0 1500 2 D 4,0 4 0 500 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 842
:admin> usbstorage -e USB storage enabled To list the contents of the attached USB device: switch:admin> usbstorage -l firmwarekey\ 0B support\ 106MB support1034\ 105MB config\ 0B 2007 Aug 15 15:13 2007 Aug 24 05:36 2007 Aug 23 06:11 2007 Aug 15 15:13 814 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 843
74% To remove an application area: switch:admin> usbstorage -r firmware FW_v6.0.0 To disable an attached USB device: switch:admin> usbstorage -d USB storage disabled supportSave, firmwareDownload, configUpload, configDownload, firmwareKeyupdate Fabric OS Command Reference 815 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 844
. On platforms supporting multiple switch domains, account information is saved only to the switch domain, in which the command was executed. Use the distribute command to distribute the account database manually to other switches in the fabric. Target switches must be configured to accept the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 845
operates on the switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. The account database supports a maximum of 256 customer created accounts. The backup account database is no longer supported on switches running Fabric OS v6.0 or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 846
, or the home AD or home Logical Fabric of your own account. • No account can disable itself. • AD or LF permissions must be a subset of the respective AD or LF permissions of the account that creates or modifies a user account. • In an LF-enabled environment, you can change the role associated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 847
in with an invalid password. Refer to the passwdCfg help page for more information. --addad | --deletead Adds one or more ADs to a user account or deletes ADs from a user account. The following operands are supported: username Specifies the account login name. Fabric OS Command Reference 819 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 848
not previously have a home AD, the home AD is set to the lowest numbered AD in the user's AD permissions. • If a home AD is specified with the --deletead Fabric or chassis permissions to a user account or deletes LF or chassis permission from a user account. The following operands are supported: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 849
following examples illustrate how to create and manage user accounts in an AD-enabled environment. To add a new account: switch:admin> userconfig --add joe -r admin -d "Joe Smith" Setting initial password for joe Enter new password: Re-type new password: Account joe has been successfully added. To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 850
switch:admin> userconfig --show test Account name: test Role: zoneadmin Description: Enabled: Yes Password Last Change Date: Sat Jun 14 2008 Password Expiration Date: Not Applicable Locked: No RoleLFMaps: zoneadmin: 1-5 admin: 6-10 user: 11-15 chassis Chassis Role: user Home Context: 4 822 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 851
LFs 1-3. switch:admin> userconfig --deletelf test -l 1-3 -c Broadcast message from root (ttyS0) Sat Jun 14 01:10:02 2008... Security Policy, Password or Account Attribute Change: test will be logged out LFs/chassis role for account test has been successfully deleted. See Also none Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 852
name, new_username cannot be another default login name. 5. If new_username is a default login name, it must indicate the same role as old_username. Notes This command is not supported on all platforms. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 853
in the time period between firmwareDownload and the next reboot, the dates can differ. Operands none Examples To display the firmware version information in a switch: switch:admin> version Kernel: 2.6.14.2 Fabric OS: v6.1.0 Made on: Wed Feb 13 06:59:17 2008 Flash: Thu Feb 14 18:38:31 2008 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 854
by the end user. The WWN is used as the license ID in many cases, but the only official string to be used for requesting licenses is the licenseidShow output. Alternately, use switchShow to display the switch WWN. In addition to the WWN, all switches have a unique 24-bit Fibre Channel address that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 855
noFCR] zone --rddelete name The zone command supports three types of operations: specific zone operations, ports. The provision (a.k.a TI Zone) is part of the defined zone configuration and does not appear in the effective zone configuration. A Maximum of 255 TI Zones can be created in one fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 856
redirect zones exist. Use zoneDelete to remove the base RD zone, "red_______base". Use cfgDelete to remove the RD zone configuration "r_e_d_i_r_c__fg." Notes TI zones are not supported in fabrics involving switches running firmware versions preceding Fabric OS v6.0. However, the existence of a TI - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 857
. Specifies the zone database location. Supported mode flag values are: 0 Uses port list members from existing zones. Removal of the last member from an active TI zone generates a warning. If the last member of a TI zone is removed, the TI zone name is removed from the defined TI zone list. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 858
again, the route is set up again and the switch generates another SCN or RSCN. TI zones with no-failover option are not supported in logical fabrics. TI zones defined in the Base Fabric for logical fabric traffic need to allow failover. f Enables failover mode. In failover mode, when the last - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 859
across a Fibre Channel router (FCR). Specify FCR to support FCR. Specify noFCR if you do not wish to support FCR. Deletes the RD Zone specified by name. RD Zones are unique in that the zone name is not user-defined. It is derived based on members and the specified configuration. Use cdfgShow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 860
zone database in the current transaction buffer: switch:admin> zone --validate -m 0 Defined configuration: cfg: t_r_a_f_f_i_c_i_s_o_c__fg bluezone; greenzone cfg: ticonfig 1,3*; 2,3 Invalid configuration * - Member does not exist # - Invalid usage of broadcast zone 832 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 861
about to prune the zone configurations, based on zone --validate output. Do you want to prune the zone configurations (yes, y, no, n): [no] y 2. Traffic isolation zone commands: To create an activated traffic isolation zone with failover enabled (default). switch:admin>zone --create -t ti purplezone - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 862
: TI Zone Name: ti_bluezone Port List: 2,2; 3,2 Configured Status: Activated / Failover-Disabled Enabled Status: Deactivated To create an FCR TI Zone within an Edge fabric where a host should to talk to target1 and target4 through port number 2 on an Edge fabric switch with a domain ID of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 863
configuration: cfg: myHTcfg zone: myHostTarget 00:3f:3f:3f:23:24:25:26 3f:3f:3f:30:32:00:00:00 To delete an RD Zone named "red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20": switch:admin>zone --rddelete red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20 See Also ad, zoneHelp Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 864
command. For the change to become effective, enable the configuration with the cfgEnable command. Notes When an FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 865
. For the change to become effective, enable the zone configuration with the cfgEnable command. Notes When an FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 866
all devices connected to switch 2, ports 12 and 14, and to the device with the World Wide Name "10:00:00:60:69:00:00:8a" (either node name or port name), at the port in the fabric to which it is connected. Examples To create three zones using a combination of port numbers and zone aliases: sw5 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 867
command. For the change to become effective, enable the configuration with the cfgEnable command. Notes When an FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 868
zone alias information Display Effective zone configuration information Add a member to a configuration Clear all zone configurations Create a zone configuration Delete a zone configuration Disable a zone configuration Enable a zone configuration Configure legacy MCDT zoning behavior Remove a member - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 869
enable the configuration with the cfgEnable command. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric zone configuration name must begin with a letter followed by any number of letters, numbers, - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 870
command. For the change to become effective, enable the configuration with the cfgEnable command. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 871
the change to become effective, enable the configuration must be enabled with the cfgEnable command. Notes When an FCS policy is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 872
to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. For the change to become effective, enable the configuration with the cfgEnable command. Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 873
Availability" for details. When FCS policy is enabled, this command can be issued on any FCS switch in the fabric. Operands This command has the following operands: "pattern" A POSIX-style regular expression used to match zone configuration names. The pattern must be enclosed in quotation - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 874
2 zoneShow 846 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 875
on the primary Fabric Configuration Server (FCS) when FCS policy is enabled. TABLE 23 Primary switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 876
. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. 848 Fabric OS Command Reference 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 877
port or the local switch is part of the current AD. View access allowed if the device attached to the port is part of the current AD. • AD0Disallowed = Allowed to execute only in AD255 and AD0 (if no ADs are configured). • AD0Only = Allowed to execute only in AD0 when ADs are not configured. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 878
roles may perform routine encryption switch management functions including the following: • Configure virtual devices & crypto LUN. • Configure LUN/tape associations. • Perform re-keying operations. • Perform firmware download. • Perform regular Fabric OS management functions. Refer to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 879
type Command Name User Admin Oper SW Zone Fabric BS Sec Admin O Disallowed eject N OM N N N O N OM Disallowed enable N OM N N N O N OM Disallowed enableEE N OM N N N O N OM Disallowed Fabric OS Command Reference 53-1001186-01 Context Switch Type VF DS VF DS VF DS VF - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 880
OS commands and permissions Refer to Table 2 for Fabric OS commands. TABLE 2 Fabric OS command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin Context Switch Type aaaConfig ad ag agShow aliAdd aliCreate - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 881
admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin 0 0 SwitchMember CH Switch Type All N/A N/A N/A All N/A N/A All All N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A All All All All All All N/A All All All All All All All All N/A Fabric OS Command Reference 853 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 882
Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin Context Switch Type chassisConfig chassisDisable chassisEnablle chassisName chassisShow cliHistory configDefault configDownload configList configRemove configShow configUpload configure configureChassis - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 883
admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain SwitchMember O OM O O O OM O N SwitchMember O OM O O O OM O N Allowed Context CH CH CH Switch Type N/A N/A N/A VF N/A CH N/A VF N/A VF N/A VF All VF All VF All VF All VF All VF - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 884
OS command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin Context Switch Type fcrlsan O OM O O O OM O N SwitchMember VF BS fcrlsanCount O OM O O O OM O N SwitchMember VF BS fcrlsanMatrix - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 885
admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin SwitchMember O OM O O N OM O N SwitchMember O OM O O N OM O N SwitchMember Context Switch Type VF All VF All VF All VF All Disallowed N/A VF All VF All VF All VF All VF All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 886
admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin O N SwitchMember O OM OM OM O OM O N Allowed O OM OM OM O OM O N Allowed Context Switch Type VF All VF All CH N/A CH N/A CH N/A CH N/A VF All CH N/A Disallowed N/A CH N/A VF - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 887
and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin OM N OM O N SwitchMember Context VF VF VF VF VF VF CH VF VF CH VF VF VF VF VF VF VF VF Switch Type All All All All All All N/A All All N/A All All All All All All N/A N/A CH N/A VF All CH N/A - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 888
command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin perfMonitorShow O VF VF VF VF VF VF VF VF VF VF VF VF VF VF VF VF VF VF Switch Type All All All All All N/A N/A N/A N/A All All All All All All All All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 889
OS command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin VF VF VF VF VF VF VF VF VF VF CH VF VF VF VF VF VF VF VF VF VF Switch Type All All N/A All All All All N/A All All All All All All All All All All All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 890
command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin Context Switch Type portSwapShow portTest portTestShow portTrunkArea portZoneShow powerOffListSet powerOffListShow psShow reboot routeHelp secActiveSize - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 891
and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin OM SwitchMember CH Switch Type N/A N/A N/A N/A N/A N/A N/A DS N/A All DS N/A N/A N/A All N/A N/A N/A All All All All All All All All All All All All N/A All N/A Fabric OS Command Reference 863 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 892
Fabric OS command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric O O O O O Allowed OM O O OM OM O O Allowed Context CH CH CH CH CH CH CH Switch Type N/A N/A N/A N/A N/A N/A N/A VF All CH N/A Disallowed N/A VF All VF All VF All VF All - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 893
command RBAC availability and admin domain type Command Name User Admin Oper Sw Zone Fabric BS Sec Admin Domain Admin Admin Admin Admin Admin Allowed O OM O O OM OM O O Allowed Context VF VF VF VF Switch Type All All All All Fabric OS Command Reference 865 53-1001186-01 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Manual v6.2.0 (53-100 - Page 894
A General Fabric OS commands and permissions 866 Fabric OS Command Reference 53-1001186-01
53-1001186-01
24 November 2008
Fabric OS
Command Reference Manual
Supporting Fabric OS v6.2.0