HP StorageWorks 8/80 HP StorageWorks 8Gb SAN Switch hardware reference manual - Page 37

Securing the switch to the outer rails, Attaching the plenum to a 4/8 or 4/16 SAN Switch

Page 37 highlights

1 2 IOIOI ! 3 mMAoaTuxTnimtEinugmNtoTscbIrOeew5Nmle:mngothr 1fo3r/6ra4cikn. 1. Plenum (installed) 2. 4/8 or 4/16 SAN Switch 25052a 3. Two screws that secure the rails to the plenum Figure 15 Attaching the plenum to a 4/8 or 4/16 SAN Switch 2. Obtain the plenum and four 8-32 x 0.312 Phillips pan-head SEMs screws from the accessory kit. These are the same screws used to attach the inner rails in Step 5 of the previous section. 3. For each inner rail (Left and Right), use one screw hole marked 8 and one screw hole marked 16 to attach the plenum. CAUTION: Verify that the open end of the plenum faces the rear of the device. When installed properly, you should see the plenum's air vent holes on one side, and the front panel of the device on the other. Securing the switch to the outer rails To secure the switch to the outer rails: 1. Insert the switch with the attached inner rails into the outer rails. NOTE: This step applies to installing a switch in HP 9000 Series, HP 10000 Series, or HP System/e racks. 2. Insert the device into the rack, and install one #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer. Repeat for the remaining side. See Figure 16 and Figure 17. 8Gb SAN Switch hardware reference manual 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

IOIOI
25052a
1
2
ATTENTION:
3
1. Plenum (installed)
3. Two screws that secure the rails to the plenum
2. 4/8 or 4/16 SAN Switch
Figure 15 Attaching the plenum to a 4/8 or 4/16 SAN Switch
2.
Obtain the plenum and four 8-32 x 0.312 Phillips pan-head SEMs screws from the accessory kit.
These are the same screws used to attach the inner rails in
Step 5
of the previous section.
3.
For each inner rail (Left and Right), use one screw hole marked
8
and one screw hole marked
16
to attach the plenum.
CAUTION:
Verify that the open end of the plenum faces the rear of the device. When installed properly, you should
see the plenum’s air vent holes on one side, and the front panel of the device on the other.
Securing the switch to the outer rails
To secure the switch to the outer rails:
1.
Insert the switch with the attached inner rails into the outer rails.
NOTE:
This step applies to installing a switch in HP 9000 Series, HP 10000 Series, or HP System/e
racks.
2.
Insert the device into the rack, and install one #10-32 x 1/2-inch Phillips pan-head screw with
captive star lock washer. Repeat for the remaining side. See
Figure 16
and
Figure 17
.
8Gb SAN Switch hardware reference manual
37