Error Code/Symptom FRU/Action 180-XXX-003 (Failed System Board LED test) 1. System Board 180-XXX-005 (Failed SCSI Backplane LED test) 1. SCSI Backplane 2. SCSI Backplane Cable 3. System Board 201-XXX-0NN (Failed Memory test, see ″Memory Settings″ on "Memory modules" on page 65 1. DIMM Location DIMM1 - DIMM4 where NN = 1 = DIMM2, 2 = DIMM1, 3 = DIMM4, 4 = DIMM3. 2. System Board 201-XXX-999 (Multiple DIMM failure, see error text.) 1. See error text for failing DIMMs 2. System Board 202-XXX-001 (Failed System Cache test) 1. VRM 1 2. Microprocessor 1 202-XXX-002 (Failed System Cache test) 1. VRM 2 2. Microprocessor 2 206-XXX-000 (Failed Diskette Drive test) 1. Cable 2. Diskette Drive 3. System Board 215-XXX-000 (Failed IDE CD-ROM test) 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 217-XXX-000 (Failed BIOS Fixed Disk test) 1. Fixed Disk 1 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-001 (Failed BIOS Fixed Disk test) 1. Fixed Disk 2 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-002 (Failed BIOS Fixed Disk test) 1. Fixed Disk 3 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-003 (Failed BIOS Fixed Disk test) 1. Fixed Disk 4 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-004 (Failed BIOS Fixed Disk test) 1. Fixed Disk 5 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-005 (Failed BIOS Fixed Disk test) 1. Fixed Disk 6 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-006 (Failed BIOS Fixed Disk test) 1. Fixed Disk 7 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-007 (Failed BIOS Fixed Disk test) 1. Fixed Disk 8 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-008 (Failed BIOS Fixed Disk test) 1. Fixed Disk 9 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 114 Hardware Maintenance Manual: xSeries 232, Type 8668