IBM 8668 Hardware Maintenance Manual - Page 131

SCSI error codes, Temperature error messages, Duplicate SCSI IDs in the same SCSI

Page 131 highlights

SCSI error codes Error Code All SCSI Errors One or more of the following might be causing the problem: v A failing SCSI device (adapter, drive, controller) v An improper SCSI configuration or SCSI termination jumper setting v Duplicate SCSI IDs in the same SCSI chain v A missing or improperly installed SCSI terminator v A defective SCSI terminator v An improperly installed cable v A defective cable FRU/Action 1. External SCSI devices must be powered-on before you power-on the server. 2. The cables for all external SCSI devices are connected correctly. 3. If you have attached an external SCSI device to the server, make sure the external SCSI termination is set to automatic. 4. The last device in each SCSI chain is terminated correctly. 5. The SCSI devices are configured correctly. Temperature error messages Message Action DASD ″X″ Over Temperature 1. Ensure system is being properly cooled; see"Temperature error (level-critical; Direct Access Storage Device messages". bay ″X″ was over temperature) DASD ″X″ Over recommended Temperature (level-warning; DASD bay ″X″ had over temperature condition) 1. Ensure system is being properly cooled; see "Temperature error messages". DASD ″X″ under recommended temperature (level-warning; direct access storage device bay ″X″ had under temperature condition) 1. Ambient temperature must be within normal operating specifications; (see"Features and specifications" on page 3.) DASD 1 Over Temperature (level-critical; sensor for DASD1 reported temperature over recommended range) 1. Ensure system is being properly cooled; see "Temperature error messages". Power Supply ″X″ Temperature Fault (level-critical; power supply ″x″ had over temperature condition) 1. Ensure system is being properly cooled; see "Temperature related system shutdown" on page 125. 2. Replace Power Supply ″X″ System board is over recommended temperature (level-warning; system board is over recommended temperature) 1. Ensure system is being properly cooled; see "Temperature error messages". 2. Replace system board System board is under recommended temperature (level-warning; system board is under recommended temperature) 1. Ambient temperature must be within normal operating specifications; (see "Features and specifications" on page 3.) System over temperature for CPU ″X″ (level-warning; CPU ″X″ reporting over temperature condition) 1. Ensure system is being properly cooled; see "Temperature error messages". System under recommended CPU ″X″ temperature (level-warning; system reporting under temperature condition for CPU ″X″) 1. Ambient temperature must be within normal operating specifications; (see "Features and specifications" on page 3. Symptom-to-FRU index 123

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

SCSI error codes
Error Code
FRU/Action
All SCSI Errors
One or more of the
following might be causing the problem:
v
A failing SCSI device (adapter, drive,
controller)
v
An improper SCSI configuration or SCSI
termination jumper setting
v
Duplicate SCSI IDs in the same SCSI
chain
v
A missing or improperly installed SCSI
terminator
v
A defective SCSI terminator
v
An improperly installed cable
v
A defective cable
1.
External SCSI devices must be powered-on before you power-on
the server.
2.
The cables for all external SCSI devices are connected correctly.
3.
If you have attached an external SCSI device to the server, make
sure the external SCSI termination is set to automatic.
4.
The last device in each SCSI chain is terminated correctly.
5.
The SCSI devices are configured correctly.
Temperature error messages
Message
Action
DASD
X
Over Temperature
(level-critical; Direct Access Storage Device
bay
X
was over temperature)
1.
Ensure system is being properly cooled
; see“Temperature error
messages”.
DASD
X
Over recommended
Temperature
(level-warning; DASD bay
X
had over temperature condition)
1.
Ensure system is being properly cooled
; see “Temperature error
messages”.
DASD
X
under recommended
temperature
(level-warning; direct access
storage device bay
X
had under
temperature condition)
1.
Ambient temperature must be within normal operating
specifications
; (see“Features and specifications” on page 3.)
DASD 1 Over Temperature
(level-critical;
sensor for DASD1 reported temperature
over recommended range)
1.
Ensure system is being properly cooled
; see “Temperature error
messages”.
Power Supply
X
Temperature Fault
(level-critical; power supply
x
had over
temperature condition)
1.
Ensure system is being properly cooled;
see “Temperature related
system shutdown” on page 125.
2.
Replace Power Supply
X
System board is over recommended
temperature
(level-warning; system board
is over recommended temperature)
1.
Ensure system is being properly cooled; see “Temperature error
messages”.
2.
Replace system board
System board is under recommended
temperature
(level-warning; system board
is under recommended temperature)
1.
Ambient temperature must be within normal operating
specifications
; (see “Features and specifications” on page 3.)
System over temperature for CPU
X
(level-warning; CPU
X
reporting over
temperature condition)
1.
Ensure system is being properly cooled; see “Temperature error
messages”.
System under recommended CPU
X
temperature
(level-warning; system
reporting under temperature condition for
CPU
X
)
1.
Ambient temperature must be within normal operating
specifications
; (see “Features and specifications” on page 3.
Symptom-to-FRU index
123