IBM 8668 Hardware Maintenance Manual - Page 133
Temperature related system shutdown, DASD checkout
UPC - 087944723158
View all IBM 8668 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Message Action Power ″X″ fan fault (level-critical; power 1. Replace power supply ″X″ supply has shutdown due to fan failure Power Supply ″X″ thermal fault 1. Replace Power supply ″X″ (level-critical; power supply ″X″ has exceed permitted temperature limits and has shutdown) System shutoff due to ″X″ over-voltage (level-critical system shutoff due to ″X″ supply over-voltage) 1. Check power supply connectors 2. Replace power supply 3. Replace power backplane System shutoff due to ″X″ under-voltage (level-critical system shutoff due to ″X″ supply under-voltage) 1. Check power supply connectors 2. Replace power supply 3. Replace power backplane System shutoff due to VRM ″X″ over voltage 1. Replace VRM ″X″ Temperature related system shutdown Message Action System shutoff due to board over temperature (level-critical; board is over temperature) 1. Ensure system is being properly cooled, see "General checkout" on page 1. 2. Replace board System shutoff due to CPU ″X″ over temperature (level-critical; CPU ″X″ is over temperature) 1. Ensure system is being properly cooled, see "General checkout" on page 1. 2. Replace CPU ″X″ System shutoff due to CPU ″X″ under 1. Ambient temperature must be within normal operating temperature (level-critical; CPU ″X″ is under specifications (see "Features and specifications" on page 3.) temperature) System shutoff due to DASD temperature (sensor X) (level-critical; DASD area reported temperature outside recommended operating range) 1. Ensure system is being properly cooled, see "General checkout" on page 1. System shutoff due to high ambient temperature (level-critical; high ambient temperature) 1. Ambient temperature must be within normal operating specifications (see "Features and specifications" on page 3.). System shutoff due to system board under 1. Ambient temperature must be within normal operating temperature (level-critical; system board is specifications (see "Features and specifications" on page 3.). under temperature) DASD checkout Message Hard drive ″X″ removal detected (level-critical; hard drive ″X″ has been removed) Action 1. Information only, take action as appropriate. Symptom-to-FRU index 125