Error Code/Symptom FRU/Action 185 (Drive startup sequence information corrupted) 1. Run Configuration/Setup 2. System Board 186 (Security hardware control logic failed) 1. Run Configuration/Setup 2. System Board 187 (VPD serial number not set.) 1. Set serial number in Setup 2. System Board 188 (Bad EEPROM CRC #2) 1. Run Configuration/Setup 2. System Board 189 (An attempt was made to access the server/workstation with invalid passwords) 1. Run Configuration/Setup, enter the administrator password 201 (Memory test error, see ″Memory Settings″ on page 30.) If the server/workstation does not have the latest level of BIOS installed, update the BIOS to the latest level and run the diagnostic program again. 1. DIMM 2. System Board 229 (Cache error) 1. Processor 2. Optional Processor (if installed) 262 (DRAM parity configuration error) 1. Run configuration / setup 2. Battery 3. System Board 289 (DIMM has been disabled by the user 1. Run Configuration/Setup, if disabled by user or system, see ″Memory Settings″ on page 30.) 2. Disabled DIMM, if not disabled by user. 3. System Board. 301 (Keyboard or keyboard controller error) 1. Keyboard 2. System Board 303 (Keyboard controller error) 1. System Board 602 (Invalid diskette boot record) 1. Diskette 2. Diskette Drive 3. Cable 4. System Board 604 (Diskette drive error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 605 (Unlock failure) 1. Diskette Drive 2. Drive Cable 3. System Board 662 (Diskette drive configuration error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 128 Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building System Type 8674