IBM 867431X Hardware Maintenance Manual - Page 82

Setting up point-to-point protocol, Baud Rate, Parity, Stop Bits, Exit Utility

Page 82 highlights

Note: The values in the following window are only examples; your settings will be different. 6. Verify the following serial port values: Baud Rate The default is 57600. Make sure that the baud rate matches the baud rate of the device you are connecting to the serial port on the Remote Supervisor Adapter. Parity The default is None. Stop Bits The default is 1. Note: The data bits value is preset to 8 and cannot be changed. For detailed information about the serial port and modem settings, see the IBM Remote Supervisor Adapter User's Guide for the xSeries 330. 7. If you make changes to the serial port settings, press F6 to apply the changes. 8. Press Esc to return to the Configuration Settings window. 9. If you need to set up PPP, go to "Setting up point-to-point protocol"; otherwise, continue with step 10. 10. Press Esc to return to the Utility program main window. 11. Use the arrow keys to select Exit Utility from the menu or press Esc to close the Utility program. 12. Remove the CD from the CD-ROM drive. The Remote Supervisor Adapter restarts automatically. Continue with "Setting up point-to-point protocol" on page 74. Setting up point-to-point protocol The Remote Supervisor Adapter serial port supports point-to-point protocol (PPP). The PPP enables TCP/IP communication over the serial port, which enables Web-based management and TELNET sessions over a modem. To set up PPP, complete the following steps: 74 Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building System Type 8674

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

Note:
The values in the following window are only examples; your settings
will be different.
6.
Verify the following serial port values:
Baud Rate
The default is 57600. Make sure that the baud rate matches the baud
rate of the device you are connecting to the serial port on the Remote
Supervisor Adapter.
Parity
The default is None.
Stop Bits
The default is 1.
Note:
The data bits value is preset to 8 and cannot be changed.
For detailed information about the serial port and modem settings, see the
IBM Remote Supervisor Adapter User
s Guide for the xSeries 330
.
7.
If you make changes to the serial port settings, press F6 to apply the changes.
8.
Press Esc to return to the Configuration Settings window.
9.
If you need to set up PPP, go to
Setting up point-to-point protocol
;
otherwise, continue with step 10.
10.
Press Esc to return to the Utility program main window.
11.
Use the arrow keys to select
Exit Utility
from the menu or press Esc to close
the Utility program.
12.
Remove the CD from the CD-ROM drive. The Remote Supervisor Adapter
restarts automatically.
Continue with
Setting up point-to-point protocol
on page 74.
Setting up point-to-point protocol
The Remote Supervisor Adapter serial port supports point-to-point protocol (PPP).
The PPP enables TCP/IP communication over the serial port, which enables
Web-based management and TELNET sessions over a modem.
To set up PPP, complete the following steps:
74
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674