Error Code/Symptom FRU/Action 01298001 (No update data for processor 1) 1. Ensure all processors are the same stepping level and cache size. 2. Processor 1 01298002 (No update data for processor 2) 1. Ensure all processors are the same stepping level and cache size. 2. Processor 2 01298101 (Bad update data for processor 1) 1. Ensure all processors are the same stepping level and cache size. 2. Processor 1 01298102 (Bad update data for processor 2) 1. Ensure all processors are the same stepping level and cache size. 2. Processor 2 I9990301 (Fixed boot sector error) 1. Hard Disk Drive 2. Cable 3. SCSI Backplane 4. System Board I9990305 (Fixed boot sector error, no operating system installed) 1. Install operating system to hard disk drive. I9990650 (AC power has been restored) 1. Check power cable 2. Check for interruption of power supply 3. Power Cable SCSI error codes Error Code All SCSI Errors One or more of the following might be causing the problem: v A failing SCSI device (adapter, drive, controller) v An improper SCSI configuration or SCSI termination jumper setting v Duplicate SCSI IDs in the same SCSI chain v A missing or improperly installed SCSI terminator v A defective SCSI terminator v An improperly installed cable v A defective cable FRU/Action 1. External SCSI devices must be powered-on before you power-on the server/workstation. 2. The cables for all external SCSI devices are connected correctly. 3. If you have attached an external SCSI device to the server/workstation, make sure the external SCSI termination is set to automatic. 4. The last device in each SCSI chain is terminated correctly. 5. The SCSI devices are configured correctly. Temperature error messages Message DASD Over recommended Temperature (sensor X) (level-warning; DASD bay ″X″ had over temperature condition) DASD under recommended temperature (sensor X) (level-warning; direct access storage device bay ″X″ had under temperature condition) Action 1. Ensure system is being properly cooled; see "Temperature checkout" on page 25. 1. Ambient temperature must be within normal operating specifications; see "Features and specifications" on page 4. Symptom-to-FRU index 131