IBM 867431X Hardware Maintenance Manual - Page 33

Temperature checkout, In addition

Page 33 highlights

7. Reinstall the server/workstation cover and connect the cables. 8. Turn on the server/workstation. 9. Start the Configuration/Setup Utility program and set configuration parameters. v Set the system date and time. v Set the power-on password. v Reconfigure the server/workstation. Temperature checkout Proper cooling of the system is important for proper operation and system reliability. For a typical xSeries server/workstation, you should make sure: v Each of the drive bays has either a drive or a filler panel installed v The top cover is in place during normal operation v There is at least 50 mm (2 inches) of ventilated space at the sides of the server/workstation and 100 mm (4 inches) at the rear of the server/workstation v The top cover is removed for no longer than 30 minutes while the server/workstation is operating v A removed hot-swap drive is replaced within two minutes of removal v Cables for optional adapters are routed according to the instructions provided with the adapters (ensure that cables are not restricting air flow) v The fans are operating correctly and the air flow is good v A failed fan is replaced within 48 hours In addition, ensure that the environmental specifications for the system are met. See "Features and specifications" on page 4. Note: The server/workstation is not designed to operate in an enclosed environment. The xSeries 330 should not reside behind a glass door in its rack enclosure. For more information on specific temperature error messages, see "Temperature error messages" on page 131. Diagnostics 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

7.
Reinstall the server/workstation cover and connect the cables.
8.
Turn on the server/workstation.
9.
Start the Configuration/Setup Utility program and set configuration
parameters.
v
Set the system date and time.
v
Set the power-on password.
v
Reconfigure the server/workstation.
Temperature checkout
Proper cooling of the system is important for proper operation and system
reliability. For a typical xSeries server/workstation, you should make sure:
v
Each of the drive bays has either a drive or a filler panel installed
v
The top cover is in place during normal operation
v
There is at least 50 mm (2 inches) of ventilated space at the sides of the
server/workstation and 100 mm (4 inches) at the rear of the server/workstation
v
The top cover is removed for no longer than 30 minutes while the
server/workstation is operating
v
A removed hot-swap drive is replaced within two minutes of removal
v
Cables for optional adapters are routed according to the instructions provided
with the adapters (ensure that cables are not restricting air flow)
v
The fans are operating correctly and the air flow is good
v
A failed fan is replaced within 48 hours
In addition, ensure that the environmental specifications for the system are met.
See
Features and specifications
on page 4.
Note:
The server/workstation is not designed to operate in an enclosed
environment. The xSeries 330 should not reside behind a glass door in its
rack enclosure.
For more information on specific temperature error messages, see
Temperature
error messages
on page 131.
Diagnostics
25