IBM 867431X Hardware Maintenance Manual - Page 141
Temperature related system shutdown, DASD checkout, Bus fault messages
View all IBM 867431X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Message Action System shutoff due to ″X″ V under 1. Check power supply connectors voltage (level-critical system shutoff due to ″X″ supply under voltage) 2. Replace power supply System shutoff due to VRM ″X″ over voltage 1. Replace power supply Temperature related system shutdown Message Action System shutoff due to board over temperature (level-critical; board is over temperature) 1. Ensure system is being properly cooled, see "Temperature checkout" on page 25. 2. Replace system board System shutoff due to CPU ″X″ over temperature (level-critical; CPU ″X″ is over temperature) 1. Ensure system is being properly cooled, see "Temperature checkout" on page 25. 2. Replace CPU ″X″ System shutoff due to CPU ″X″ under 1. Ambient temperature must be within normal operating temperature (level-critical; CPU ″X″ is under specifications, see "Features and specifications" on page 4. temperature) 2. Replace CPU ″X″ System shutoff due to DASD temperature (sensor X) (level-critical; DASD area reported temperature outside recommended operating range) 1. Ensure system is being properly cooled, see "Temperature checkout" on page 25. 2. Replace SCSI Backplane System shutoff due to high ambient temperature (level-critical; high ambient temperature) 1. Ambient temperature must be within normal operating specifications, see "Features and specifications" on page 4. 2. Replace Front Panel Assembly System shutoff due to system board under temperature (level-critical; system board is under temperature) 1. Ambient temperature must be within normal operating specifications, see "Features and specifications" on page 4. 2. Replace System Board DASD checkout Message Hard drive ″X″ removal detected (level-critical; hard drive ″X″ has been removed) Action 1. Information only, take action as appropriate. Bus fault messages The System Event/Error Log may contain 12C bus fault messages from both the Service Processor Diagnostic and the Advanced System Management processor, indicated by the source DIAGS and SERVPROC, respectively. The format of the DIAGS messages from revision TTY119 and later are as either: 12C Bus x bad or devices on this bus are functioning incorrectly. or Symptom-to-FRU index 133