Icom IC-7600 Instruction Manual - Page 116

■ Memory scan operation, EXIT/SET], SCAN] F-5, RF/SQL], MEMO] F-1, SEL No.] F-4, SELECT] F-3

Page 116 highlights

7 SCANS ■ Memory scan operation q P ush [EXIT/SET] several times to close a multi- function screen, if necessary. w Select memory mode. e Push [SCAN] (F-5) to select the scan screen. r Set [RF/SQL] open or closed. • See p. 105 for squelch condition. • If the [RF/SQL] control function is set as "AUTO," the squelch is always open in SSB, CW, RTTY and PSK modes. (pgs. 2, 33, 128) t Push [MEMO] (F-1) to start the memory scan. • " " and decimal points blink while scanning. y W hen the scan detects a signal, the scan stops, pauses or ignores it depending on the resume set- ting and the squelch condition. u To cancel the scan, push [MEMO] (F-1) . • Rotating the main dial also cancels the scan. 2 or more memory channels must be programmed for memory scan to start. [RF/SQL] F-1 MEMO F-5 EXIT/SET SCAN Main dial ■ Select memory scan operation q P ush [EXIT/SET] several times to close a multi- function screen, if necessary. w Select memory mode. e Push [SCAN] (F-5) to select the scan screen. r Set [RF/SQL] open or closed. • See p. 105 for squelch condition. • If the [RF/SQL] control function is set as "AUTO," the squelch is always open in SSB, CW, RTTY and PSK modes. (pgs. 2, 33, 128) t Push [MEMO] (F-1) to start the memory scan. • " " and decimal points blink while scanning. y Push [SEL No.] (F-4) several times to select the select scan number from ★1, ★2, ★3 and ★1,2,3. u P ush [SELECT] (F-3) to start select memory scan; push [SELECT] (F-3) again to return to memory scan, if desired. • " " blinks instead of " " during select memory scan. i W hen the scan detects a signal, the scan stops, pauses or ignores it depending on the resume set- ting and the squelch condition. o To cancel the scan, push [MEMO] (F-1). • Rotating the main dial also cancels the scan. 2 or more memory channels must be designated as select memory channels, as well as the same select scan channel number, for select memory scan to start. 109 SEL No. F-4 SCAN F-5 [RF/SQL] F-1 F-3 MEMO SELECT EXIT/SET Main dial

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Memory scan operation
q
Push
[EXIT/SET]
several t±mes to close a mult±-
funct±on screen, ±f necessary.
w
Select memory mode.
e
Push
[SCAN] (F-5)
to select the scan screen.
r
Set
[RF/SQL]
open or closed.
• See p. 105 for squelch cond±t±on.
If the
[RF/SQL]
control funct±on ±s set as “AUTO,” the
squelch ±s always open ±n SSB, CW, RTTY and PSK
modes. (pgs. 2, 33, 128)
t
Push
[MEMO] (F-1)
to start the memory scan.
” and dec±mal po±nts bl±nk wh±le
scann±ng.
y
When the scan detects a s±gnal, the scan stops,
pauses or ±gnores ±t depend±ng on the resume set-
t±ng and the squelch cond±t±on.
u
To cancel the scan, push
[MEMO] (F-1)
.
• Rotat±ng the ma±n d±al also cancels the scan.
2 or more memory channels must be programmed
for memory scan to start.
Select memory scan operation
q
Push
[EXIT/SET]
several t±mes to close a mult±-
funct±on screen, ±f necessary.
w
Select memory mode.
e
Push
[SCAN] (F-5)
to select the scan screen.
r
Set
[RF/SQL]
open or closed.
• See p. 105 for squelch cond±t±on.
If the
[RF/SQL]
control funct±on ±s set as “AUTO,” the
squelch ±s always open ±n SSB, CW, RTTY and PSK
modes. (pgs. 2, 33, 128)
t
Push
[MEMO] (F-1)
to start the memory scan.
” and dec±mal po±nts bl±nk wh±le
scann±ng.
y
Push
[SEL No.] (F-4)
several t±mes to select the
select scan number from
1,
2,
3 and
1,2,3.
u
Push
[SELECT] (F-3)
to start select memory scan;
push
[SELECT] (F-3)
aga±n to return to memory
scan, ±f des±red.
” bl±nks ±nstead of
” dur±ng select memory scan.
i
When the scan detects a s±gnal, the scan stops,
pauses or ±gnores ±t depend±ng on the resume set-
t±ng and the squelch cond±t±on.
o
To cancel the scan, push
[MEMO] (F-1)
.
• Rotat±ng the ma±n d±al also cancels the scan.
2 or more memory channels must be des±gnated
as select memory channels, as well as the same
select scan channel number, for select memory
scan to start.
F-1
F-5
EXIT/SET
Main dial
[RF/SQL]
SCAN
MEMO
F-3
SELECT
F-1
F-4
F-5
EXIT/SET
Main dial
[RF/SQL]
SCAN
MEMO
SEL No.
109
7
SCANS