Icom IC-7600 Instruction Manual - Page 81

■ AGC function, ◇ Selecting the preset value, ◇ Setting the AGC time constant preset value

Page 81 highlights

4 RECEIVE AND TRANSMIT ■ AGC function The AGC (auto gain control) controls receiver gain to produce a constant audio output level even when the received signal strength varies greatly. The transceiver has 3 preset AGC characteristics (time constant: fast, mid, slow) for non-FM mode. The FM mode AGC time constant is fixed as 'FAST' (0.1 sec.) and AGC time constant cannot be changed. D Selecting the preset value [AGC] 1 q Select any non-FM mode. w P ush [AGC] (MF5) several times to select AGC fast, AGC medium (MID) or AGC slow. 2 3 4 F-4 EXIT/SET Main dial DEF 5 D Setting the AGC time constant preset value 6 q Select any non-FM mode. • AGC set mode screen w P ush and hold [AGC] (MF5) for 1 sec. to enter 7 AGC set mode. e P ush [AGC] (MF5) several times to select FAST 8 time constant. r R otate the main dial to set the desired time constant for 'AGC FAST.' 9 • AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned ­OFF. 10 • Push and hold [DEF] (F-4) for 1 sec. to select a default value. 11 t P ush [AGC] (MF5) to select medium time con- stant. y R otate the main dial to set the desired time con- stant for 'AGC MID.' • AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned ­OFF. • Push and hold [DEF] (F-4) for 1 sec. to select a default • Selectable AGC time constant (unit: sec.) Mode SSB Default 0.3 (FAST) 2.0 (MID) 6.0 (SLOW) Selectable AGC time constant OFF, 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 12 13 14 value. u P ush [AGC] (MF5) to select slow time constant. i R otate the main dial to set the desired time con- stant for 'AGC SLOW.' • AGC time constant can be set between 0.1 to 8.0 sec. (depends on mode) or turned ­OFF. • Push and hold [DEF] (F-4) for 1 sec. to select a default CW RTTY PSK 0.1 (FAST) 0.5 (MID) 1.2 (SLOW) 0.1 (FAST) 0.5 (MID) 1.2 (SLOW) OFF, 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 OFF, 0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 15 16 17 value. o S elect another non-FM mode, then repeat steps e to i if desired. !0 Push [EXIT/SET] to exit the AGC set mode screen. 3.0 (FAST) AM 5.0 (MID) OFF, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 7.0 (SLOW) FM 0.1 (FAST) Fixed 18 19 20 21 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

AGC function
The AGC (auto ga±n control) controls rece±ver ga±n to
produce a constant aud±o output level even when the
rece±ved s±gnal strength var±es greatly.
The transce±ver has 3 preset AGC character±st±cs
(t±me constant: fast, m±d, slow) for non-FM mode.
The FM mode AGC t±me constant ±s f±xed as
‘FAST’ (0.1 sec.) and AGC t±me constant cannot
be changed.
D
Selecting the preset value
q
Select any non-FM mode.
w
Push
[AGC] (MF5)
several t±mes to select AGC
fast, AGC med±um (MID) or AGC slow.
F-4
EXIT/SET
Main dial
DEF
[AGC]
D
Setting the AGC time constant preset value
q
Select any non-FM mode.
w
Push and hold
[AGC] (MF5)
for 1 sec. to enter
AGC set mode.
e
Push
[AGC] (MF5)
several t±mes to select FAST
t±me constant.
r
Rotate the ma±n d±al to set the des±red t±me con-
stant for ‘AGC FAST.’
AGC t±me constant can be set between 0.1 to 8.0 sec.
(depends on mode) or turned OFF.
Push and hold
[DEF] (F-4)
for 1 sec. to select a default
value.
t
Push
[AGC] (MF5)
to select med±um t±me con-
stant.
y
Rotate the ma±n d±al to set the des±red t±me con-
stant for ‘AGC MID.’
AGC t±me constant can be set between 0.1 to 8.0 sec.
(depends on mode) or turned OFF.
Push and hold
[DEF] (F-4)
for 1 sec. to select a default
value.
u
Push
[AGC] (MF5)
to select slow t±me constant.
i
Rotate the ma±n d±al to set the des±red t±me con-
stant for ‘AGC SLOW.’
AGC t±me constant can be set between 0.1 to 8.0 sec.
(depends on mode) or turned OFF.
Push and hold
[DEF] (F-4)
for 1 sec. to select a default
value.
o
Select another non-FM mode, then repeat steps
e
to
i
±f des±red.
!
0
Push
[EXIT/SET]
to ex±t the AGC set mode screen.
• AGC set mode screen
• Selectable AGC time constant
(un±t: sec.)
Mode
Default
Selectable AGC time constant
SSB
0.3 (FAST)
OFF
,
0.1, 0.2, 0.3, 0.5, 0.8, 1.2,
1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0
2.0 (MID)
6.0 (SLOW)
CW
0.1 (FAST)
OFF
,
0.1, 0.2, 0.3, 0.5, 0.8, 1.2,
1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0
0.5 (MID)
1.2 (SLOW)
RTTY
PSK
0.1 (FAST)
OFF
,
0.1, 0.2, 0.3, 0.5, 0.8, 1.2,
1.6, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0
0.5 (MID)
1.2 (SLOW)
AM
3.0 (FAST)
OFF
,
0.3, 0.5, 0.8, 1.2, 1.6, 2.0,
2.5, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0
5.0 (MID)
7.0 (SLOW)
FM
0.1 (FAST)
F±xed
74
4
RECEIVE AND TRANSMIT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21