Icom IC-7600 Instruction Manual - Page 51

◇ Keyer set mode, Keyer, Repeat, Dot/Dash, Ratio - specifications

Page 51 highlights

4 RECEIVE AND TRANSMIT D Keyer set mode This set mode is used to set the memory keyer repeat time, dash weight, paddle specifications, keyer type, etc. • Setting contents q D uring CW mode operation, push [KEYER] (F-3) to select memory keyer screen. w P ush [EXIT/SET] to select memory keyer menu, then push [CW KEY] (F-4) to select keyer set mode. e P ush [Y] (F-1) or [Z] (F-2) to select the desired set item. r Set the desired condition using the main dial. • Push and hold [DEF] (F-4) for 1 sec. to select the default condition or value. t Push [EXIT/SET] twice to normal screen. Keyer Repeat Time When sending CW using the repeat timer, this item sets the time between transmission. Dot/Dash Ratio This item sets the dot/dash ratio. Keying weight example: Morse code "K" Weight setting: DOT (fixed*) DASH DASH 1:1:3 (default) Weight setting: Adjusted Adjustable range SPACE (fixed*) *SPACE and DOT length can be adjusted with [KEY SPEED] only. Rise Time This item sets the rise time of the transmitted CW envelope. • About rise time Tx Key action Rx Tx output power Set Tx power level 0 Rise time Time DEF / CW KEY F-4 F-1 F-2 F-3 EXIT/SET KEYER Main dial • Keyer set mode screen 2s • 1 to 60 sec. in 1 sec. steps can be selected. (default: 2 sec.) 1:1:3.0 • 1:1:2.8 to 1:1:4.5 (in 0.1 steps) can be selected. (default: 1:1:3.0) 4ms • 2, 4, 6, 8 or 10 msec. can be selected. (default: 4 msec.) Key clicks on nearby frequencies can be generated if the rise time of a CW waveform is too short. ☞ Continues to the next page. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

D
Keyer set mode
Th±s set mode ±s used to set the memory keyer repeat
t±me, dash we±ght, paddle spec±ficat±ons, keyer type,
etc.
• Setting contents
q
Dur±ng CW mode operat±on, push
[KEYER] (F-3)
to select memory keyer screen.
w
Push
[EXIT/SET]
to select memory keyer menu,
then push
[CW KEY] (F-4)
to select keyer set
mode.
e
Push
[
Y
] (F-1)
or
[
Z
] (F-2)
to select the des±red
set ±tem.
r
Set the des±red cond±t±on us±ng the ma±n d±al.
Push and hold
[DEF] (F-4)
for 1 sec. to select the
default cond±t±on or value.
t
Push
[EXIT/SET]
tw±ce to normal screen.
Main dial
F-1
F-2
F-3
EXIT/SET
F-4
KEYER
CW KEY
/
DEF
• Keyer set mode screen
Keyer
Repeat
Time
2s
When send±ng CW us±ng the repeat t±mer, th±s ±tem
sets the t±me between transm±ss±on.
1 to 60 sec. ±n 1 sec. steps can be selected.
(default: 2 sec.)
Dot/Dash
Ratio
1:1:3.0
Th±s ±tem sets the dot/dash rat±o.
Keying weight example:
Morse code “K”
DASH
Weight setting:
1:1:3 (default)
Weight setting:
Adjusted
DASH
DOT (fixed*)
Adjustable range
SPACE (fixed*)
*SPACE and DOT length can be
adjusted with [KEY SPEED] only.
1:1:2.8 to 1:1:4.5 (±n 0.1 steps) can be selected.
(default: 1:1:3.0)
Rise
Time
4ms
Th±s ±tem sets the r±se t±me of the transm±tted CW
envelope.
Key action
Tx output power
• About rise time
Rise time
Tx
Rx
Set Tx power level
Time
0
2, 4, 6, 8 or 10 msec. can be selected.
(default: 4 msec.)
Key cl±cks on nearby frequenc±es can be generated
±f the r±se t±me of a CW waveform ±s too short.
Cont±nues to the next page.
44
4
RECEIVE AND TRANSMIT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21