12 CONTROL COMMAND 155 D Command table (continued) Cmd. Sub cmd. Data Description 1A 05 0095 00 Voice memory transmission OFF with [F1]- [F4] on the keyboard 01 Voice memory transmission ON with [F1]- [F4] on the keyboard 0096 00 Memory keyer transmission OFF with [F1]- [F4] on the keyboard 01 Memory keyer transmission ON with [F1]- [F4] on the keyboard 0097 00 CI-V transceive OFF 01 CI-V transceive ON 0098 00 CI-V selection for [USB-B] usage 01 Decode selection for [USB-B] usage 0099 00 300 bps selection for decode speed 01 1200 bps selection for decode speed 02 4800 bps selection for decode speed 03 9600 bps selection for decode speed 04 19200 bps selection for decode speed 0100 00 English keyboard selection 01 Japanese keyboard selection 02 United Kingdom keyboard selection 03 French keyboard selection 04 French (Canadian) keyboard selection 05 German keyboard selection 06 Portuguese keyboard selection 07 Portuguese (Brazilian) keyboard selection 08 Spanish keyboard selection 09 Spanish (Latin American) keyboard selection 10 Italian keyboard selection 0101 0010 to Send/read keyboard repeat delay 0100 (0010=100 msec., 0100=1000 msec.; 50 msec. steps) 0102 00 to 31 Send/read keyboard repeat speed (00=2.0 cps, 31=30.0 cps) 0103 00 Scope indication during TX OFF 01 Scope indication during TX ON 0104 00 Scope max. hold function OFF 01 Scope max. hold function ON 0105 00 Filter center selection for scope center frequency (center mode only) 01 Carrier point center selection for scope center frequency (center mode only) 02 Carrier point center (Abs. Freq.) selection for scope center frequency (center mode only) 0106 see p. 158 Send/read waveform color for receiving signal 0107 see p. 158 Send/read waveform color for max. hold 0108 00 SLOW selection for scope sweep speed in ±2.5 kHz span 01 MID selection for scope sweep speed in ±2.5 kHz span 02 FAST selection for scope sweep speed in ±2.5 kHz span 0109 00 SLOW selection for scope sweep speed in ±5 kHz span 01 MID selection for scope sweep speed in ±5 kHz span 02 FAST selection for scope sweep speed in ±5 kHz span 0110 00 SLOW selection for scope sweep speed in ±10 kHz span 01 MID selection for scope sweep speed in ±10 kHz span 02 FAST selection for scope sweep speed in ±10 kHz span 0111 00 SLOW selection for scope sweep speed in ±25 kHz span 01 MID selection for scope sweep speed in ±25 kHz span 02 FAST selection for scope sweep speed in ±25 kHz span 0112 00 SLOW selection for scope sweep speed in ±50 kHz span 01 MID selection for scope sweep speed in ±50 kHz span 02 FAST selection for scope sweep speed in ±50 kHz span Cmd. Sub cmd. Data Description 1A 05 0113 00 SLOW selection for scope sweep speed in ±100 kHz span 01 MID selection for scope sweep speed in ±100 kHz span 02 FAST selection for scope sweep speed in ±100 kHz span 0114 00 SLOW selection for scope sweep speed in ±250 kHz span 01 MID selection for scope sweep speed in ±250 kHz span 02 FAST selection for scope sweep speed in ±250 kHz span 0115 see p. 158 Scope edge frequencies for 0.03 to 1.60 MHz band 0116 see p. 158 Scope edge frequencies for 1.60 MHz to 2.00 MHz band 0117 see p. 158 Scope edge frequencies for 2.00 MHz to 6.00 MHz band 0118 see p. 158 Scope edge frequencies for 6.00 MHz to 8.00 MHz band 0119 see p. 158 Scope edge frequencies for 8.00 MHz to 11.00 MHz band 0120 see p. 158 Scope edge frequencies for 11.00 MHz to 15.00 MHz band 0121 see p. 158 Scope edge frequencies for 15.00 MHz to 20.00 MHz band 0122 see p. 158 Scope edge frequencies for 20.00 MHz to 22.00 MHz band 0123 see p. 158 Scope edge frequencies for 22.00 MHz to 26.00 MHz band 0124 see p. 158 Scope edge frequencies for 26.00 MHz to 30.00 MHz band 0125 see p. 158 Scope edge frequencies for 30.00 MHz to 45.00 MHz band 0126 see p. 158 Scope edge frequencies for 45.00 MHz to 60.00 MHz band 0127 00 Auto monitor function OFF during voice memory transmission 01 Auto monitor function ON during voice memory transmission 0128 03 to 10 Send/read voice memory short play time (03=3 sec., 10=10 sec.) 0129 05 to 15 Send/read voice memory normal record time (05=5 sec., 15=15 sec.) 0130 00 Normal selection for contest number style 01 "190→ANO" selection for contest number style 02 "190→ANT" selection for contest number style 03 "90→NO" selection for contest number style 04 "90→NT" selection for contest number style 0131 01 M1 selection for count up trigger channel 02 M2 selection for count up trigger channel 03 M3 selection for count up trigger channel 04 M4 selection for count up trigger channel 0132 0001 to Send/read present number 9999 (0001=1, 9999=9999) 0133 01 to 60 Send/read CW keyer repeat time (01=1 sec., 60=60 sec.) 0134 28 to 45 Send/read CW keyer dot/dash ratio (28=1:1:2.8, 45=1:1:4.5) 0135 00 2 msec. selection for rise time of the transmitted CW envelope 01 4 msec. selection for rise time of the transmitted CW envelope 02 6 msec. selection for rise time of the transmitted CW envelope 03 8 msec. selection for rise time of the transmitted CW envelope 04 10 msec. selection for rise time of the transmitted CW envelope 0136 00 Normal selection for paddle polarity 01 Reverse selection for paddle polarity 0137 00 Straight selection for keyer type 01 BUG-KEY selection for keyer type 02 ELEC-KEY selection for keyer type 0138 00 Mic. up/down keyer function OFF 01 Mic. up/down keyer function ON