Icom IC-7600 Instruction Manual - Page 159
◇ Command table, Sub cmd., Description
View all Icom IC-7600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
CONTROL COMMAND 12 D Command table Cmd. Sub cmd. Data Description 00 see p. 157 Send frequency data (transceive) 01 see p. 157 Operating mode selection for transceive 02 see p. 159 Read band edge frequencies 03 see p. 157 Read operating frequency 04 see p. 157 Read operating mode 05 see p. 157 Set operating frequency 06 see p. 157 Operating mode selection for transceive 07 Select VFO mode B0 Exchange main and sub bands B1 Equalize main and sub bands C0 Turn the dualwatch OFF C1 Turn the dualwatch ON D0 Select main band D1 Select sub band 08 Select memory mode 0001 to Select memory channel 0099 (0001=M-CH01, 0099=M-CH99) 0100 Select program scan edge channel P1 0101 Select program scan edge channel P2 09 Memory write 0A Memory to VFO 0B Memory clear 0E 00 Scan stop 01 Programmed/memory scan start 02 Programmed scan start 03 :F scan start 12 Fine programmed scan start 13 Fine :F scan start 22 Memory scan start 23 Select memory scan start A1 Select :F scan span ±5 kHz A2 Select :F scan span ±10 kHz A3 Select :F scan span ±20 kHz A4 Select :F scan span ±50 kHz A5 Select :F scan span ±100 kHz A6 Select :F scan span ±500 kHz A7 Select :F scan span ±1 MHz B0 Set as non-select channel B1 Set as select channel (The previously set number by CI-V is set after turning power ON, or "1" is selected if no selec- tion is performed.) 01 Set as select channel "★1" 02 Set as select channel "★2" 03 Set as select channel "★3" B2 00 Set "ALL" for select memory scan 01 Set "★1" for select memory scan 02 Set "★2" for select memory scan 03 Set "★3" for select memory scan D0 Set scan resume OFF D3 Set scan resume ON 0F 00 Turn the split function OFF 01 Turn the split function ON Cmd. Sub cmd. 10 11 12 13 00 01 02 14 01 02 03 06 07 08 09 0A 0B 0C 0D 0E 0F 10 12 14 15 16 17 19 15 01 02 11 12 13 14 Data 00 01 02 03 04 05 06 07 08 00 06 12 18 0000 0001 0100 0101 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 00 01 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 0000 to 0255 Description Select 10 Hz (1 Hz) tuning step Select 100 Hz tuning step Select 1 kHz tuning step Select 5 kHz tuning step Select 9 kHz tuning step Select 10 kHz tuning step Select 12.5 kHz tuning step Select 20 kHz tuning step Select 25 kHz tuning step Send/read attenuator OFF Send/read 6 dB attenuator Send/read 12 dB attenuator Send/read 18 dB attenuator Send/read ANT1 selection (RX ANT OFF) Send/read ANT1 selection (RX ANT ON) Send/read ANT2 selection (RX ANT OFF) Send/read ANT2 selection (RX ANT ON) Announce all data with voice synthesizer Announce frequency and S-meter level with voice synthesizer Announce receive mode with voice synthesizer Send/read [AF] level (0000=max. CCW, 0255=max. CW) Send/read [RF] level (0000=max. CCW, 0255=11 o'clock) Send/read [SQL] level (0000=11 o'clock, 0255=max. CW) Send/read [NR] level (0000=0%, 0255=100%) Send/read inner [TWIN PBT] position (0000=max. CCW, 0128=center, 0255=max. CW) Send/read outer [TWIN PBT] position (0000=max. CCW, 0128=center, 0255=max. CW) Send/read CW pitch (0000=300 Hz, 0128=600 Hz, 0255=900 Hz; 5 Hz steps) Send/read [RF POWER] level (0000=max. CCW, 0255=max. CW) Send/read [MIC GAIN] level (0000=max. CCW, 0255=max. CW) Send/read [KEY SPEED] level (0000=max. CCW, 0255=max. CW) Send/read [NOTCH] position (0000=max. CCW, 0128=center, 0255=max. CW) Send/read COMP level (0000=0, 0255=10) Send/read [BK-IN DELAY] position (0000=max. CCW, 0255=max. CW) Send/read [BAL] position (0000=max. CCW, 0128=center, 0255=max. CW) Send/read NB level (0000=0%, 0255=100%) Send/read DRIVE gain (0000=0%, 0255=100%) Send/read Monitor gain (0000=0%, 0255=100%) Send/read VOX gain (0000=0%, 0255=100%) Send/read Anti VOX gain (0000=0%, 0255=100%) Send/read BRIGHT level (0000=0%, 0255=100%) Read squelch condition (squelch close) Read squelch condition (squelch open) Read S-meter level (0000=S0, 0120=S9, 0241=S9+60 dB) Read RF power meter (0000=0%, 0143=50%, 0213=100%) Read SWR meter (0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0) Read ALC meter (0000=0, 0120=Max.) Read COMP meter (0000=0 dB, 0130=15 dB, 0241=30 dB) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 152