3Com 3C13886 Installation Guide - Page 123
Table 4-8, Description, Attribute, Synchronous, V.35, RS449, X.21, RS530
UPC - 662705478456
View all 3Com 3C13886 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
3Com Router Module Guide 115200 -- 10 m (32.8 ft.) -- 64000 2048000 Chapter 4 50 m (164 ft.) 30 m (98.4 ft.) Note: When a V.24 cable is used, the baud rate of the ROUTER 4-PORT ENHANCED SERIAL FIC in synchronous mode shall not exceed 64 Kbps. 4.3.2 Interface Attributes The following table describes the interface attributes of the ROUTER 4-PORT ENHANCED SERIAL: Table 4-8 Interface attributes of the ROUTER 4-PORT/8-PORT ENHANCED SERIAL Attribute Description Synchronous Asynchronous Connector DB-28 4 Number of connectors 8 Interface standard and operating mode V.24 DTE, DCE V.35, RS449, X.21, RS530 DTE DCE RS232 Min. baud rate(bps) 1200 Max. baud rate(bps) 64 k 1200 4.096 M 2.048 M 300 115.2 4-14
3Com Router Module Guide
Chapter 4
4-14
115200
10 m (32.8 ft.)
64000
50 m (164 ft.)
––
––
2048000
30 m (98.4 ft.)
Note:
When a V.24 cable is used, the baud rate of the ROUTER 4-PORT ENHANCED SERIAL FIC in
synchronous mode shall not exceed 64 Kbps.
4.3.2
Interface Attributes
The following table describes the interface attributes of the ROUTER 4-PORT
ENHANCED SERIAL:
Table 4-8
Interface attributes of the ROUTER 4-PORT/8-PORT ENHANCED SERIAL
Description
Attribute
Synchronous
Asynchronous
Connector
DB-28
Number of connectors
4
8
V.24
V.35, RS449, X.21, RS530
Interface standard and
operating mode
DTE, DCE
DTE
DCE
RS232
Min. baud rate(bps)
1200
1200
300
Max. baud rate(bps)
64 k
4.096 M
2.048 M
115.2